US$329.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 695-2019: Sulfur Hydrogen Gas Detectors Status: Valid JJG 695: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 695-2019 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Sulfur Hydrogen Gas Detectors
| Valid |
JJG 695-2019
|
JJG 695-2003 | English | 170 |
Add to Cart
|
0--9 seconds. Auto-delivery
|
Verification Regulation of Sulfur Hydrogen Gas Detectors
| Obsolete |
JJG 695-2003
|
JJG 695-1990 | English | 519 |
Add to Cart
|
4 days [Need to translate]
|
Regulation of Verification for Hydrogen Sulfide Gas Analyzer
| Obsolete |
JJG 695-1990
|
PDF similar to JJG 695-2019
Standard similar to JJG 695-2019 JJG 714 JJG 635 JJG 688 JJG 700 JJF 703
Basic data Standard ID | JJG 695-2019 (JJG695-2019) | Description (Translated English) | Sulfur Hydrogen Gas Detectors | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.020 | Word Count Estimation | 14,131 | Date of Issue | 2019 | Date of Implementation | 2020-03-27 | Issuing agency(ies) | State Administration for Market Regulation |
JJG 695-2019: Sulfur Hydrogen Gas Detectors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Sulfur Hydrogen Gas Detectors
National Measurement Verification Regulations of the People's Republic of China
Hydrogen sulfide gas detector
2019-09-27 release
2020-03-27 Implementation
Issued by the State Administration of Market Supervision and Administration
Hydrogen sulfide gas detector
Verification regulations
Replace JJG 695-2003
Focal point: National Technical Committee for Environmental Chemometrics
Main drafting unit: Shanghai Institute of Metrology and Testing Technology
China Testing Technology Research Institute
Participated in the drafting unit: Gansu Metrology Research Institute
Shanghai Ladi Technology Co:, Ltd:
This regulation is entrusted to the National Environmental Chemometrics Technical Committee for interpretation
The main drafters of this regulation:
Chen Lan (Shanghai Institute of Metrology and Testing Technology)
Qing Liu (China Institute of Testing Technology)
Cai Jianhua (Shanghai Institute of Metrology and Testing Technology)
Participating drafters:
Shi Jianwei (Shanghai Institute of Metrology and Testing Technology)
Wanli (China Institute of Testing Technology)
Shi Liyu (Gansu Metrology Research Institute)
Qi Jiaju (Shanghai Laidi Technology Co:, Ltd:)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 Overview (1)
3 Measurement performance requirements (1)
4 General technical requirements (1)
4:1 Appearance and structure (1)
4:2 Marks and logos (1)
4:3 Power-on inspection (2)
4:4 Alarm function (2)
4:5 Insulation resistance (2)
5 Control of measuring instruments (2)
5:1 Verification conditions (2)
5:2 Verification items (2)
5:3 Verification method (3)
5:4 Processing of verification results (5)
5:5 Verification period (5)
Appendix A Verification Record Format (6)
Appendix B Format of the inner pages of the certificate of verification/certification result (8)
Introduction
This regulation is a revision of JJG 695-2003: The revision of this regulation refers to GB 12358-2006 "Workplace
The general technical requirements of the environmental gas detection and alarm instrument of the Institute ", GB/T 13971-2013" Technical Article of UV Gas Analyzer
"", GB/T 25923-2010 "Online Gas Analyzer Technical Conditions" and other technical regulations: With JJG 695-
Compared with:2003, the main technical changes except for editorial changes are as follows:
--- Modified the scope of application (see 1):
--- Modified the measurement performance requirements, respectively listed the measurement performance requirements of the analyzer and the detection alarm (see 3):
--- Delete the alarm setting error verification item, and add the alarm function verification item to the instrument with alarm function
(See 4:4):
--- Modify the appearance item in the original regulations to "appearance and structure", "signs and logo", "power-on inspection", etc:
Three items (see 4:1, 4:2, 4:3):
--- Delete the insulation strength verification items, and delete the insulation strength tester and insulation strength verification method:
--- The relative expansion uncertainty and inclusion factor of gas reference materials are determined by the original relative expansion uncertainty
If it is greater than 2%, k = 3 is modified to a relative expansion uncertainty of not greater than 2%, k = 2: When using a gas dilution device,
The relative expansion uncertainty of the standard gas after dilution shall meet the above requirements (see 5:1:2:1):
--- Changed the format of the verification record, the verification certificate and the internal page format of the verification result notification (see Appendix A, Appendix
B):
The previous releases of this regulation are:
--- JJG 695-2003;
--- JJG 695-1990:
Verification Regulation of Hydrogen Sulfide Gas Detector
1 Scope
This regulation is applicable to the first verification, subsequent verification and in-use inspection of hydrogen sulfide gas detector: Hydrogen sulfide gas
The detector includes a hydrogen sulfide gas detection alarm and a hydrogen sulfide gas analyzer:
2 Overview
Hydrogen sulfide gas detector (hereinafter referred to as instrument) is mainly used to detect sulfide in the workplace environment and production process
The concentration of hydrogen gas: For the instrument with alarm function, when the displayed value is greater than the alarm setting value, there should be sound, light or vibration
Call the police: The instrument is mainly composed of gas circuit unit, detection unit, signal processing unit, alarm unit and display unit:
The detection principle is mainly electrochemical method, spectroscopy, etc: According to the sampling method, it is divided into diffusion type, positive pressure conveying type and pump suction type:
According to the usage mode, it is divided into portable and fixed: It can be divided into non-continuous measurement and continuity measurement according to working mode:
3 Measurement performance requirements
See Table 1 for metering performance requirements:
Table 1 Measurement performance requirements
Project hydrogen sulfide gas analyzer hydrogen sulfide gas detection alarm
Indication error ± 10%
± 2μmol/mol or ± 10%
(Just one of them)
Response time ≤90s ≤60s
Repeatability ≤1:5% ≤2%
drift
Zero drift ± 2% FS
Range drift ± 3% FS
Note: FS indicates the full scale of the instrument:
4 General technical requirements
4:1 Appearance and structure
4:1:1 The instrument should not have any appearance damage that would affect its normal operation: The surface of the newly manufactured instrument should be smooth, flat and painted
The coating is uniform without peeling and rusting:
4:1:2 The adjustment parts shall be able to operate normally, and the fasteners shall be free from looseness:
4:2 Marks and logos
The instrument name, model, number, name of the manufacturer, date of manufacture, measurement range, maximum allowable error, etc:
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 695-2019_English be delivered?Answer: Upon your order, we will start to translate JJG 695-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 695-2019_English with my colleagues?Answer: Yes. The purchased PDF of JJG 695-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 695-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 695-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|