JJG 588-2018

Chinese Standard: 'JJG 588-2018'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
JJG 588-2018English379 Add to Cart Days<=4 Impulse Peak Voltmeters Valid JJG 588-2018
JJG 588-2018Chinese24 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]  

   

BASIC DATA
Standard ID JJG 588-2018 (JJG588-2018)
Description (Translated English) Impulse Peak Voltmeters
Sector / Industry Metrology & Measurement Industry Standard
Word Count Estimation 22,226
Date of Issue 2018-02-27
Date of Implementation 2018-08-27
Older Standard (superseded by this standard) JJG 588-1996
Drafting Organization National High Voltage Metering Station, State Grid Hubei Electric Power Company Electric Power Research Institute
Administrative Organization National Electromagnetic Measurement Technical Committee High Voltage Measurement Subcommittee
Regulation (derived from) AQSIQ Announcement No. 26 of 2018
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine

JJG 588-2018
(Impact peak voltage meter verification procedure)
National Metrology Verification Regulations of the People's Republic
Impact peak voltmeter
Published on.2018-02-27
2018-08-27 implementation
The General Administration of Quality Supervision, Inspection and Quarantine issued
Impact peak voltmeter
Verification procedure
Replace JJG 588-1996
Focal Point. National Electromagnetic Measurement Technical Committee High Voltage Measurement Subcommittee
Main drafting unit. National High Voltage Metering Station
State Grid Hubei Electric Power Company Electric Power Research Institute
Participated in the drafting unit. State Grid Jiangsu Electric Power Company Electric Power Research Institute
State Grid Shanghai Electric Power Company Electric Power Research Institute
State Grid Heilongjiang Electric Power Company Electric Power Research Institute
This regulation entrusts the National Electromagnetic Measurement Technical Committee High Voltage Measurement Subcommittee to explain
The main drafters of this procedure.
Liu Shaobo (National High Voltage Metering Station)
Long Zhaozhi (National High Voltage Metering Station)
Wang Tao (State Grid Hubei Electric Power Company Electric Power Research Institute)
Participate in the drafters.
Zhou Zhicheng (State Grid Jiangsu Electric Power Company Electric Power Research Institute)
Jin Wei (State Grid Shanghai Electric Power Company Electric Power Research Institute)
Gongyou (State Grid Heilongjiang Electric Power Company Electric Power Research Institute)
table of Contents
Introduction (II)
1 range (1)
2 References (1)
3 terms (1)
3.1 Impact Peak Voltmeter (1)
4 Overview (1)
5 Metrological performance requirements (1)
5.1 Basic error (1)
5.2 Accuracy level (2)
5.3 Repeatability (2)
5.4 Short-term stability (2)
6 General technical requirements (2)
6.1 Appearance (2)
6.2 Input impedance (2)
6.3 Insulation resistance (2)
6.4 Power frequency withstand voltage (2)
7 measuring instrument control (2)
7.1 Verification conditions (2)
7.2 Verification items and verification methods (3)
7.3 Processing of verification results (5)
7.4 Verification cycle (5)
Appendix A Verifying the Original Record Format (6)
Appendix B Format of the Certificate/Verification Result Notice (Page 2) (11)
Appendix C Verification Certificate/Verification Result Notice Verification Result Format (Page 3) (12)
introduction
This regulation is based on JJF1001-2011 "General Measurement Terms and Definitions", JJF1002-2010 "National Measurement
The rules for the preparation of verification procedures are formulated.
This regulation amends JJG 588-1996, compared with JJG 588-1996, except for editorial changes.
The technical changes are as follows.
--- Modify the representation of the basic error of "measurement performance" (see 5.1);
--- "Measuring performance" increases the need for repeatability (see 5.3);
--- Increase the standard wave source time parameters (see 7.1.4);
--- Removed the content of the original procedure using the comparative method to verify the basic error;
---Modified the requirements of the "basic error" verification voltage point and the number of measurements (see 7.2.2.4);
--- Removed the original procedure "basic error" plus test requirements.
The previous versions of this procedure were released as follows.
---JJG 588-1996.
Impact peak voltmeter verification procedure
1 Scope
This procedure is applicable to the first verification of the digital impact peak voltmeter with a measurement range of ±(100~1600)V.
Subsequent verification and in-use inspection.
2 reference files
This procedure refers to the following documents.
GB/T 16896.1 High voltage impulse measuring instruments and software Part 1 requirements for instruments
GB/T 16927.1 High Voltage Test Technique Part 1. General Definitions and Test Requirements
For dated references, only the dated version applies to this Code; any undated quotation
The latest version (including all amendments) applies to this procedure.
3 terms
The terms and definitions established in GB/T 16896.1 and GB/T 16927.1 apply to this standard.
3.1 Impact peak voltmeter impulseIvoltometer
An instrument capable of measuring the peak value of the surge voltage. There should be no short-term overshoot or short time near the peak of the surge voltage.
High frequency oscillation.
[GB/T 16896.1-20053.1.3]
4 Overview
The digital impulse peak voltmeter (hereinafter referred to as the peak table) is an instrument for measuring the peak value of the surge voltage. when using it,
The peak meter is connected to the secondary voltage output of the surge voltage divider through a transmission cable to measure the voltage of the surge voltage divider.
Output voltage peak. By inputting the voltage division ratio of the surge voltage divider on the peak surface plate, the peak table display unit can
The primary voltage peak applied to the surge voltage divider is directly displayed. The peak table is generally composed of a secondary attenuator, A/D
The acquisition conversion unit and the display device are composed.
5 Metrological performance requirements
5.1 Basic error
The maximum allowable error of the peak voltage of the peak meter is as shown in equation (1).
Δ=±(a%Ux b%Um) (1)
In the formula.
Δ---maximum allowable error, V or kV;
a---the error coefficient related to the reading value;
b---the error coefficient related to the range;
Ux---the reading value of the peak table to be inspected, V or kV;
Related standard:   JJG 596-2012  JJG 757-2018
Related PDF sample:   JJG 376-2007  JJG 1148-2018
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response
Field Test Asia Limited | Taxed in Singapore: 201302277C | Copyright 2012-2020