US$679.00 ยท In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 586-2006: Verification Regulation of Soap Film Flow meter Status: Valid JJG 586: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 586-2006 | English | 679 |
Add to Cart
|
5 days [Need to translate]
|
Verification Regulation of Soap Film Flow meter
| Valid |
JJG 586-2006
|
JJG 586-1989 | English | 479 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of Soap Film Standard Facility on Gases Flow
| Obsolete |
JJG 586-1989
|
PDF similar to JJG 586-2006
Basic data Standard ID | JJG 586-2006 (JJG586-2006) | Description (Translated English) | Verification Regulation of Soap Film Flow meter | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Classification of International Standard | 17.120 | Word Count Estimation | 26,290 | Date of Issue | 2006-09-06 | Date of Implementation | 2007-03-06 | Older Standard (superseded by this standard) | JJG 586-1989 | Quoted Standard | JJF 1015-2002; JJF 1016-2002; GB/T 12810-1991; JB/T 9329-1999; GB/T 17626.2-1998 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to soap film flowmeter type evaluation (prototype test), initial verification, testing and use of follow-up inspection. |
JJG 586-2006: Verification Regulation of Soap Film Flow meter---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Soap Film Flow meter
National Metrology Verification Regulations of the People's Republic
Soap film flowmeter
Released on.2006-09-06
2007-03-06 implementation
The General Administration of Quality Supervision, Inspection and Quarantine issued
Soap film flowmeter verification procedures
Film Flow meter
Replace JJG 586-1989
This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 6,.2006, and
It will take effect on March 6,.2007.
Focal Point. National Traffic Capacity Measurement Technical Committee
Main drafting unit. China Institute of Metrology
Beijing Institute of Metrology and Measurement Science
Participated in the drafting unit. Zhejiang Institute of Quality and Technical Supervision and Testing
Liaoning Institute of Metrology
Qingdao Hengyuan Instrument Co., Ltd.
Shenyang Beixing Flow Meter Factory
Wuhan Tianhong Intelligent Instrument Factory
This regulation entrusts the National Traffic Capacity Measurement Technical Committee to explain
The main drafters of this procedure.
Xu Yinghua (China Institute of Metrology)
Yang Youtao (Beijing Institute of Metrology and Measurement Science)
Participate in the drafters.
Shen Wenxin (Zhejiang Institute of Quality and Technical Supervision and Testing)
Chen Mei (Liaoning Institute of Metrology)
Wang Yizheng (Qingdao Hengyuan Instrument Co., Ltd.)
Chen Ping (Shenyang Beixing Flow Meter Factory)
Tang Lei (Beijing Institute of Metrology and Measurement Science)
Li Hongjie (Wuhan Tianhong Intelligent Instrument Factory)
table of Contents
1 Scope (1)
2 Citations (1)
3 Overview (1)
3.1 Use (1)
3.2 Structure type (1)
3.3 Working principle (1)
4 Metrological performance requirements (2)
4.1 Accuracy level and maximum allowable error (2)
4.2 Repeatability (2)
5 General technical requirements (2)
5.1 Appearance (2)
5.2 Technical requirements (3)
6 measuring instrument control (4)
6.1 Type Evaluation (4)
6.2 First verification, subsequent verification and in-use inspection (4)
6.3 Processing of verification results (9)
6.4 Verification cycle (9)
Appendix A Type Evaluation Outline (10)
Appendix B Soap Membrane Gas Flow Standard Device (15)
Appendix C Additional Conditions for Class 0.5 Flow Meters (16)
Appendix D Additional Errors in Soap Membrane Flowmeters (17)
Appendix E Distilled Water Density Table (18)
Appendix F Specifications and reference dimensions of soap tube (19)
Appendix G dn Numerical Table (20)
Appendix H Format of verification certificate and verification result page (21)
Soap film flowmeter verification procedures
1 Scope
This procedure is applicable to the type evaluation (prototype test), initial verification, subsequent verification and use of soap film flowmeter.
test.
2 Citations
The provisions of the following standards and procedures constitute provisions of this regulation by reference.
JJF1015-2002 General specification for type evaluation and type approval of measuring instruments
JJF1016-2002 Guidelines for the preparation of type evaluation guides for measuring instruments
GB/T 12810-1991 Laboratory glass instrument glass measuring device capacity calibration and use method
JB/T 9329-1999 Basic environmental conditions and test methods for instrumentation transportation, transportation and storage
GB/T 17626.2-1998 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test
When using this procedure, care should be taken to use the current valid version of the above cited documents.
3 Overview
3.1 Use
A soap membrane flow meter (hereinafter referred to as a flow meter) is a flow meter that measures the flow rate of a small gas. Direct reading glass
Tube soap membrane flowmeter (hereinafter referred to as soap membrane flowmeter) and a soap membrane flowmeter with a pair of electronic sensors mounted on the soap tube
(hereinafter referred to as electronic soap membrane flowmeter). Direct reading glass tube soap membrane flowmeter, the maximum flow is generally 12L/min. Electricity
The sub-soap membrane flowmeter, the maximum flow rate is generally 60L/min. When the soap membrane flowmeter needs to be used as a device, it should be
The relevant provisions of Appendix B.
3.2 Structure type
The soap membrane flowmeter is a soap tube with a scale, and there is an air inlet under the soap tube, the lowermost end of the soap tube
A rubber ball is attached, and the rubber ball is filled with a soap solution. The electronic soap membrane flowmeter is equipped with a lower limit sensing on the outer wall of the soap tube tube.
And upper limit sensors are equipped with display instruments.
The structure of the soap membrane flowmeter is shown in Figure 1. The structure of the electronic soap membrane flowmeter is shown in Figure 2.
3.3 Working principle
As shown in Figure 1 and Figure 2, the working principle of the soap membrane flowmeter is the gas flowing out of the gas source, which is regulated by flow.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 586-2006_English be delivered?Answer: Upon your order, we will start to translate JJG 586-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 586-2006_English with my colleagues?Answer: Yes. The purchased PDF of JJG 586-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 586-2006?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 586-2006 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|