HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 574-2004 English PDF

US$369.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 574-2004: Verification Regulation of Impression Tonometers
Status: Valid

JJG 574: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 574-2004English369 Add to Cart 3 days [Need to translate] Verification Regulation of Impression Tonometers Valid JJG 574-2004
JJG 574-1988English519 Add to Cart 4 days [Need to translate] Verification Regulation of Impression Tonometers Obsolete JJG 574-1988

PDF similar to JJG 574-2004


Standard similar to JJG 574-2004

GB/T 36126   JJG 577   GB/T 1885   JJG 564   JJG 567   

Basic data

Standard ID JJG 574-2004 (JJG574-2004)
Description (Translated English) Verification Regulation of Impression Tonometers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 14,171
Date of Issue 2004-06-04
Date of Implementation 2004-12-01
Older Standard (superseded by this standard) JJG 574-1988
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to indentation tonometer (hereinafter referred to as tonometer) the initial verification, testing and use of follow-up inspection.

JJG 574-2004: Verification Regulation of Impression Tonometers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Impression Tonometers National Metrology Verification Regulations of the People's Republic Indented tonometer Released on June.2004 Implementation of.2004-12-01 The General Administration of Quality Supervision, Inspection and Quarantine issued Indentation tonometer verification procedure Imp Replace JJG 574-1988 This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on June 4,.2004, and Implemented on December 1,.2004. Focal Point. National Pressure Measurement Technical Committee Drafting unit. Shanghai Institute of Metrology and Testing Technology This regulation entrusts the National Pressure Measurement Technical Committee to explain Drafters of this procedure. Wang Jinsuo (Shanghai Institute of Metrology and Testing Technology) Tu Limeng (Shanghai Institute of Metrology and Testing Technology) Dai Xiaohua (Shanghai Institute of Metrology and Testing Technology)

table of Contents

1 Scope (1) 2 Overview (1) 3 Metrological performance requirements (1) 3.1 Quality tolerance (1) 3.2 Sliding performance of the needle in the leg tube (1) 3.3 indication tolerance (1) 4 General technical requirements (3) 4.1 Appearance (3) 4.2 Zero alignment deviation (3) 5 measuring instrument control (3) 5.1 Verification conditions (3) 5.2 Verification project (4) 5.3 Verification method (4) 5.4 Verification result processing (5) 5.5 Verification cycle (5) Appendix A Indentation tonometer verification record format (6) Appendix B Verification Certificate (inside page) format (8) Appendix C Format of the verification result (inside page) (9) Indentation tonometer verification procedure

1 Scope

This procedure is applicable to the first verification, subsequent verification and use of the indentation tonometer (hereinafter referred to as tonometer). Test.

2 Overview

The tonometer is a special instrument for measuring the intraocular pressure of the human body. Its working principle is to target the cornea according to the pressure of a certain quality. Intraocular pressure is measured indirectly by the depth of depression, and each square on the scale is equivalent to a corneal depression depth of 1/20 mm. root According to the indentation depth value and the quality of the needle and the weight, the intraocular pressure value is obtained by checking the eye pressure conversion table. The structure of the tonometer is shown in Figure 1.

3 Metrological performance requirements

3.1 Quality tolerance 3.1.1 The assembly quality of the tonometer fixed weight, needle, hammer bow and pointer is 5.5g, and the allowable deviation should be in accordance with Table 1. Provisions. Table 1 Pointer indicates scale tolerance /g ±0.20 3.1.2 The total mass of the tonometer (except the handle) is 16.5g, and the allowable deviation is ±0.5g. 3.1.3 The weight of the tonometer attached weight should meet the requirements of Table 2. Table 2 Additional weight specification additional weight quality tolerance /g 7.5 2.0 4.5 9.5 ±0.02 3.2 The sliding performance of the needle in the leg tube The tonometer is tilted from the horizontal position. The angle of the needle should be automatically slid down in the leg tube within 28°. There should be no jamming. Or stick to the phenomenon. 3.3 indication tolerance The tonometer measures the indentation depth of the needle (0~0.90)mm, corresponding to the tonometer scale scale (0~18)

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 574-2004_English be delivered?

Answer: Upon your order, we will start to translate JJG 574-2004_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 574-2004_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 574-2004_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 574-2004?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 574-2004 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.