HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 544-2011 English PDF

US$329.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 544-2011: Verification Regulation of Pressure Controllers
Status: Valid

JJG 544: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 544-2011English329 Add to Cart 3 days [Need to translate] Verification Regulation of Pressure Controllers Valid JJG 544-2011
JJG 544-1997English479 Add to Cart 4 days [Need to translate] Verification Regulation of Pressure Contuoller Obsolete JJG 544-1997

PDF similar to JJG 544-2011


Standard similar to JJG 544-2011

GB/T 36126   JJG 577   GB/T 1885   JJG 126   JJG 540   JJG 539   

Basic data

Standard ID JJG 544-2011 (JJG544-2011)
Description (Translated English) Verification Regulation of Pressure Controllers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 14,166
Date of Issue 2011-12-28
Date of Implementation 2012-06-28
Older Standard (superseded by this standard) JJG 544-1997
Regulation (derived from) AQSIQ Announcement No. 205 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to pressure, vacuum and pressure vacuum passive controller (hereinafter referred to as controller) for initial verification, testing and use of follow-up checks.

JJG 544-2011: Verification Regulation of Pressure Controllers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Pressure Controllers State verification procedures People's Republic of China pressure controller Issued on. 2011-12-28 2012-06-28 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Pressure Controller test procedures Replacing JJG 544-1997 The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on December 28, 2011, and from From June 28, 2012 into effect. Focal point. the National Technical Committee of pressure measurement Drafting. Shanghai Institute of Measurement and Testing Participated in the drafting unit. Shanghai Baohua Controls Co. The measurement procedure commissioned the National Technical Committee is responsible for interpreting pressure The main drafters of this procedure. Huan Lun (Shanghai Institute of Measurement and Testing) Tu Li Meng (Shanghai Institute of Measurement and Testing) Drafters participate. Ship Road (Shanghai Baohua Controls Co., Ltd)

table of Contents

1 Scope (1) 2 Overview (1) 3 Terms and Definitions (1) 4 metering performance requirements (2) 4.1 accuracy class (2) 4.2 control voltage range (2) 4.3 Setpoint deviation (2) 4.4 repeatability error (2) 4.5 switching difference (3) 4.6 Insulation resistance (3) 4.7 dielectric strength (3) 5 General technical requirements (3) 5.1 identification (3) 5.2 Appearance (3) 6 Control of measuring instruments (3) 6.1 Verification Project (3) 6.2 test conditions (4) 6.3 Verification Methods (4) Processing 6.4 Verification Results (6) 6.5 test cycle (6) Appendix A pressure controller test recording format (7) Appendix B pressure controller test certificate-page format (8) Appendix C pressure controller test results in the notice page format (9) Pressure Controller test procedures

1 Scope

The order applies to pressure, vacuum and pressure in the vacuum passive controller (hereinafter referred to as the controller) initial verification, Use and subsequent verification check.

2 Overview

Pressure controller for industrial process measurement and control system for controlling the pressure of a special instrument. Its working principle is When the pressure reaches the set value input to control or alarm. Pressure controller according to the type of pressure-sensing elements can be divided into diaphragm, bellows, bellows, spring and piston tube Type, etc; whether by switching difference adjustable switching difference can be divided into adjustable and non-adjustable switching difference; according to the set point is adjustable to Divided into adjustable set point and the set point is not adjustable.

3 Terms and Definitions

3.1 pressure controller pressureswitch When the input pressure reaches the set value, the output contacts off the role the accused played a pressure control and alarm The role of the instrument. 3.2 pressure control range range The controller can control the pressure range. 3.3 Setpoint (value) setpoint Enter the desired pressure generating control or alarm value. 3.4 switch value switchingvalue When the digital control instrumentation stroke (or the next trip), the output change from one state to another state measured input value. Switching on the value of high-switchingvalue 3.5 When the input pressure rises, the controller generates pressure control or alarm signal upon changes. 3.6 under switch value low-switchingvalue When you enter a pressure drop, the controller generates pressure control or alarm signal upon changes. 3.7 switching difference differentialgap Difference between the value and the lower value of the toggle switch on the same setpoint. 3.8 Setpoint deviation setpointerror Output variable according to the requirements output, the difference between the set value and the measured actual value. 3.9 Setpoint (value) range setpointrange Adjustable set point controller, the setpoint can be adjusted for the difference between the maximum pressure and the minimum pressure value.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 544-2011_English be delivered?

Answer: Upon your order, we will start to translate JJG 544-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 544-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 544-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 544-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 544-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.