HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJG 366-2004 English PDF

US$419.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 366-2004: Verification Regulation of Earth Resistance Meters
Status: Valid

JJG 366: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 366-2004English419 Add to Cart 3 days [Need to translate] Verification Regulation of Earth Resistance Meters Valid JJG 366-2004
JJG 366-1986English519 Add to Cart 4 days [Need to translate] Verification Regulation of Earth Resistance Meter Obsolete JJG 366-1986

PDF similar to JJG 366-2004


Standard similar to JJG 366-2004

JJF 1234   JJG 229   JJG 376   JJG 892   JJG 963   JJG 843   

Basic data

Standard ID JJG 366-2004 (JJG366-2004)
Description (Translated English) Verification Regulation of Earth Resistance Meters
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Classification of International Standard 17.220.20
Word Count Estimation 16,119
Date of Issue 2004-06-04
Date of Implementation 2004-12-01
Older Standard (superseded by this standard) JJG 366-1986
Quoted Standard JJF 1001; JJF 1059; JB/T 9289; GB/T 7676.1; GB/T 7676.9; GB/T 13978
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to digital ground resistance meter and analog ground resistance meter initial verification, testing and use of follow-up inspection. This procedure does not apply AC mains power supply and manufacturing requirements for special grounding resistance meter.

JJG 366-2004: Verification Regulation of Earth Resistance Meters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Earth Resistance Meters National Metrology Verification Regulations of the People's Republic Grounding resistance meter Released on June.2004 Implementation of.2004-12-01 The General Administration of Quality Supervision, Inspection and Quarantine issued Grounding resistance meter verification procedure Replacing JJG 366-1986 This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on June 4,.2004, and Implemented on December 1,.2004. Focal Point. National Electromagnetic Measurement Technical Committee Main drafting unit. Liaoning Institute of Metrology Participated in the drafting unit. Hangzhou Quality and Technology Supervision and Inspection Institute This procedure entrusts the National Electromagnetic Measurement Technical Committee to explain The main drafters of this procedure. Sun Lihua (Liaoning Institute of Metrology) Cui Jihong (Liaoning Institute of Metrology) Yang Li (Liaoning Institute of Metrology) Participate in the drafters. Wang Yueying (Liaoning Institute of Metrology) Jiang Xueping (Hangzhou Quality and Technical Supervision and Inspection Institute)

table of Contents

1 Scope (1) 2 Citations (1) 3 terms (1) 4 Overview (1) 4.1 Use (1) 4.2 Principles (1) 5 Metrological performance requirements (2) 5.1 indication error (2) 5.2 Accuracy level (2) 5.3 Location Impact (2) 5.4 Effect of auxiliary grounding resistance (2) 5.5 Influence of ground voltage (3) 6 General technical requirements (3) 6.1 Appearance (3) 6.2 Power check (3) 6.3 Insulation resistance (3) 6.4 Dielectric strength test (3) 7 Measuring instrument control (3) 7.1 Verification conditions (3) 7.2 Verification project (4) 7.3 Verification method (4) 7.4 Processing of verification results (7) 7.5 Verification cycle (7) Appendix A Original Record (8) Appendix B Grounding Resistance Meter Verification Certificate (inside page) format (10) Appendix C Grounding resistance meter verification result notification (inside page) format (11) Grounding resistance meter verification procedure

1 Scope

This procedure applies to the initial verification, subsequent verification and use of digital grounding resistance meters and analog grounding resistance meters. In the test. This procedure does not apply to AC grid power supplies and ground resistance meters manufactured for special requirements.

2 Citations

This procedure refers to the following documents. JJF1001-1998 "General Terms and Definitions of Measurement" JJF1059-1999 "Measurement and Expression of Measurement Uncertainty" JB/T 9289-1999 "Grounding Resistance Meter" GB/T 7676.1-1998 "Direct-effect analogue indicating electrical measuring instruments and their accessories, Part 1. Definitions and With requirements GB/T 7676.9-1998 "Direct-effect analogue indicating electrical measuring instruments and their accessories, part 9. recommended test Method of inspection GB/T 13978-1992 "General technical conditions for digital multimeters" When using this procedure, care should be taken to use the current valid version of the above cited documents.

3 terms

3.1 Grounding resistance meter A meter used to measure the resistance between a ground conductor and earth. 3.2 Ground resistance The resistance between the ground conductor and the earth. The increased potential of the conductor when the AC test current flows through the ground conductor Divided by the test current, the quotient is the value of the grounding resistance. 3.3 Auxiliary Grounding Resistance When measuring the grounding resistance, the resistance between the auxiliary grounding electrode used as the potential terminal and the current terminal and the ground. 3.4 Ground voltage The interference voltage on the ground conductor is excluded by the voltage generated by the test current.

4 Overview

4.1 Use The grounding resistance meter is mainly used to directly measure the grounding resistance and soil resistivity of various grounding devices. 4.2 Principle The working principle of the grounding resistance meter is divided into reference voltage comparison type and reference current and voltage drop type.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 366-2004_English be delivered?

Answer: Upon your order, we will start to translate JJG 366-2004_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 366-2004_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 366-2004_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 366-2004?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 366-2004 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.