HOME   Cart(5)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJG 2053-2016 English PDF

US$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 2053-2016: Measuring Instruments of Mass
Status: Valid

JJG 2053: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 2053-2016English279 Add to Cart 3 days [Need to translate] Measuring Instruments of Mass Valid JJG 2053-2016
JJG 2053-2006English399 Add to Cart 3 days [Need to translate] Verification Scheme for Measuring Instruments of Mass Obsolete JJG 2053-2006
JJG 2053-1990English359 Add to Cart 3 days [Need to translate] Verification Scheme of Measuring Instruments for Mass Obsolete JJG 2053-1990

PDF similar to JJG 2053-2016


Standard similar to JJG 2053-2016

JJF 1943   GB/T 36126   GB/T 1885   JJF 2043   JJF 2044   JJF 2053   

Basic data

Standard ID JJG 2053-2016 (JJG2053-2016)
Description (Translated English) Measuring Instruments of Mass
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Word Count Estimation 12,144
Date of Issue 2016-11-25
Date of Implementation 2017-05-25
Older Standard (superseded by this standard) JJG 2053-2006
Regulation (derived from) State Administration of Quality Supervision, Inspection and Quarantine Notice No.116 of 2016
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJG 2053-2016: Measuring Instruments of Mass

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Quality measuring instruments) National People's Republic of China Metrological Verification System Quality measuring instruments 2016-11-25 release 2017-05-25 implementation State Administration of Quality Supervision, Inspection and Quarantine issued Quality measurement equipment test system table Replacing JJG 2053-2006 Focal unit. National Quality and Density Metrology Technical Committee Drafting unit. China Institute of Metrology Shanghai Institute of Metrology and Testing Technology The verification system is commissioned by the National Quality and Density Metrology Technical Committee to explain The main drafters of this procedure. Yao Hong (China Institute of Metrology) Yu Peiying (Shanghai Institute of Metrology and Testing Technology) Participate in the drafters. Ren Xiaoping (China Institute of Metrology)

table of Contents

Introduction (II) 1 Scope (1) 2 Quality measurement (1) 2.1 1kg quality benchmark (1) 2.2 1kg ~ 1g quality sub-reference group (2) 3 quality measurement standards (2) 3.1 Composition of quality standard devices (2) 3.2 standard weight (3) 4 Work measuring instruments (4) 4.1 Composition of working measuring instruments (4) 4.2 Working weights (4) 4.3 Working Weighing (4) 5 Checklist of quality measuring instruments (5)

Introduction

The test system table is based on JJF1104-2003 "National Metrological Verification System Table preparation rules" as the basis for JJG 2053-2006. Compared with JJG 2053-2006, in addition to editorial changes, the test system The main changes are as follows. - sent to the International Bureau of Metrology (BIPM) according to the national kilogram of the original kiln and the national kilogram The results of the calibration, modified the measurement uncertainty of the two reference weights. --- modified the original balance of the technical indicators. As in.2005, China Institute of Metrology introduced a vacuum Learning quality comparison instrument and supporting the air density measurement system, the laboratory has updated the original instrument balance, so the original balance Of the technical indicators and ancillary equipment has changed. --- modified the quality of the sub-benchmark group of technical indicators, such as material density, measurement results of the uncertainty, the original Of the kilograms of sub-benchmark weight range extended to 1kg ~ 1g of the national quality of the sub-benchmark group weight. --- Change the "conversion quality" to "agreed quality". --- increase the "quality comparison instrument" the use of the scope and value of traceability approach. --- check the system block diagram in accordance with the previous text to do the appropriate changes. The test system table of the previous release. --- JJG 2053-2006; --- JJG 2053-1990; --- JJG 2053-1981. Quality measurement equipment test system table

1 Scope

This test system table applies to the mass transfer of the quality measuring instrument. The verification system table specifies the national mass measurement basis for the mass unit "kg", the quality measurement standard and the work meter The use of measuring instruments; the full set of basic devices, metrological parameters included in the accuracy level measuring instruments; Home quality benchmarks by means of the quality of the sub-reference group and the standard measuring instruments to the work of measuring instruments to pass the quality unit of the value of the process Order, given its uncertainty or maximum allowable error and basic transfer method. In the actual use of the test system, the quality of the standard weight and the weight of the work can be used according to the nominal value Need to be in the corresponding accuracy level up, down to expand. All quality values used in accordance with the law must be within the specified accuracy range, with a certain proportion can be determined strictly And 1kg quality reference weight (also known as. national kilogram of the original device) corresponds to the quality value. All the quality of the use of law The value must be in accordance with the test system table to 1kg quality benchmark weight trace; in carrying out the calibration, can also be used as the amount Value based on the source.

2 quality measurement benchmark

The quality measurement basis includes 1kg quality reference, 1kg ~ 1g quality sub-reference group. 2.1 1 kg quality benchmark 2.1.1 1kg quality reference weight for reproduction and preservation according to the international kilogram of the original instrument obtained by the quality of single Position, and with 1kg ~ 1g quality sub-reference group and the standard measuring instruments to the work of measuring instruments to pass the amount of unit weight Value to ensure the unity of domestic quality measurement. 2.1.2 1kg quality reference weight and its ancillary equipment 2.1.2.1 China's highest quality of the quality of the weight and ancillary equipment include. 1kg quality benchmark weight, 1kg quality testify the benchmark weight (also known as the national kilogram of the original instrument), the corresponding quality comparison instrument, air density measurement Quantity system. 2.1.2.2 1kg quality reference weight, number 60, is the diameter and height are 39mm platinum iridium alloy straight cylinder, Of which. platinum accounted for 90%, iridium accounted for 10%. The weight of the weight of the nominal value of 1kg, the vacuum quality value from the international meter The volume (BIPM) gives the uncertainty of the measurement results expressed as the synthetic standard uncertainty (k = 1) BIPM's latest certificate). 2.1.2.3 1kg quality testify the reference weight, number 64, is the diameter and height are 39mm platinum iridium alloy straight round Column, of which. platinum accounted for 90%, iridium accounted for 10%. The weight of the weight of the nominal value of 1kg, the vacuum in the quality of the value BIPM gives the uncertainty of the measurement results to the synthetic standard uncertainty (k = 1) (expressed as BIPM's latest Certificate). 2.1.2.4 quality comparison device, weighing 1kg, the actual scale value of 0.1μg, a single measurement of the standard deviation is not At 0.6 μg. 2.1.2.5 Air density measurement system

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 2053-2016_English be delivered?

Answer: Upon your order, we will start to translate JJG 2053-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 2053-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 2053-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 2053-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 2053-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.