HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 2034-2005 English PDF

US$239.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 2034-2005: Verification Scheme of Measuring Instruments for Luminous Intensity
Status: Valid

JJG 2034: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 2034-2005English239 Add to Cart 3 days [Need to translate] Verification Scheme of Measuring Instruments for Luminous Intensity Valid JJG 2034-2005
JJG 2034-1989English319 Add to Cart 3 days [Need to translate] Verification Scheme of Measuring Instruments for Luminous Intensity Obsolete JJG 2034-1989

PDF similar to JJG 2034-2005


Standard similar to JJG 2034-2005

JJG 879   JJF 1106   JJG 810   JJF 2034   JJF 2002   JJG 2028   

Basic data

Standard ID JJG 2034-2005 (JJG2034-2005)
Description (Translated English) Verification Scheme of Measuring Instruments for Luminous Intensity
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A60
Classification of International Standard 17.180
Word Count Estimation 9,976
Date of Issue 2005-03-03
Date of Implementation 2005-06-03
Older Standard (superseded by this standard) JJG 2034-1989
Summary This standard applies to luminous intensity verification of measuring instruments. It specifies the unit of luminous intensity candela (cd) the use of national benchmarks, including a full set of basic benchmark measuring instruments, benchmarks, and by means of metrological parameters Vice benchmark reference work, the standard measurement equipment delivered to the working units of measure luminous intensity program, indicating the uncertainty and the basic test methods.

JJG 2034-2005: Verification Scheme of Measuring Instruments for Luminous Intensity

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Scheme of Measuring Instruments for Luminous Intensity People's Republic of China National Metrology Verification System Table Luminous intensity measuring instruments 2005-03-03 released 2005-06-03 implementation General Administration of Quality Supervision, Inspection and Quarantine released Luminous intensity measuring instruments calibration system table Replacing JJG 2034-1989 The verification system table by the State General Administration of Quality Supervision, Inspection and Quarantine on March 03,.2005 approval, And since June 3,.2005 shall come into force. Administrative Organization. National Optical Metering Technology Committee Drafting Organization. China Institute of Metrology The verification system table by the National Optical Metrology Technical Committee responsible for the interpretation The system draftsman. Jiang Xiaomei (China Institute of Metrology) Gao Zhizhong (China Institute of Metrology)

table of Contents

1 Scope (1) 2 measurement standards (1) 2.1 luminosity national benchmark (1) 2.2 Photometric National Sub-benchmark (1) 2.3 luminous intensity of the benchmark (1) 2.4 luminous intensity of work benchmarks (2) 3 measurement standards (2) 3.1 a luminous intensity standards (2) 3.2 two luminous intensity standards (2) 4 Working measuring instruments (2) 4.1 work metering incandescent light (2) 4.2 work metering tungsten halogen lamp (3) 4.3 Luminous intensity measuring instrument (3) 5 Luminous Intensity Gauge Verification System Block Diagram (3) Luminous intensity measuring instrument verification system table *

1 Scope

This verification system table is suitable for the verification of luminous intensity measuring instruments. It specifies the luminous intensity of candela (cd) The use of the national baseline, the full set of basic measuring instruments included in the baseline, the metrological parameters of the baseline, Sub-benchmark, working standards, standards to the work of measuring instruments transmitted luminous intensity unit of the program, indicating its uncertainty Degree and the basic test methods.

2 measurement standards

2.1 luminosity national benchmark 2.1.1 Photometric National Reference Used to reproduce the luminous intensity unit --- the amount of candela (cd), and through the luminous Degree of sub-benchmark, working standards to luminous intensity standard lamp, luminous intensity measuring instrument transmission unit volume to ensure that the national Uniformity of light value. The measured luminous intensity range of values (400 ~ 1200) cd. 2.1.2 luminosity National benchmark standard by a group of not less than 5 high stability conical compensated electrical calibration radiometer composition. 2.1.3 luminosity National benchmark recurrence luminous intensity unit of magnitude expansion uncertainty. U = 0.20%, k = 2. 2.1.4 Photometric National Reference Absolute irradiance measurements are transmitted to luminosity references on a photometric reference device. 2.1.5 Luminosity National benchmark to the luminous intensity of the benchmark reference value for the best measurement of capacity. U = 0.24%, k = 2. 2.2 luminosity national benchmarks 2.2.1 Photometric National Sub-benchmark Through the comparison with the luminosity national benchmark to determine the value, the measured luminous intensity value range Wai for the (400 ~ 1200) cd. 2.2.2 luminosity National Sub Reference Standards from a group of not less than 5 stable performance Cone cavity compensated type of electrical calibration Radiation Accounting composition. 2.2.3 luminosity national sub-benchmark recurrence luminous intensity unit value of the extended uncertainty. U = 0.22%, k = 2. 2.2.4 Photometric National Sub Reference Absolute radiative measurement is transmitted to the luminosity secondary reference on the photometric secondary reference device Magnitude. 2.2.5 Photometric States Sub-benchmark to the luminous intensity of the benchmark for the transfer of the best measurement of the amount of capacity as follows. U = 0.26%, k = 2. Note. Since.2003, the original "Metrology Verification System" collectively referred to as the "Metrology Verification System Table." 2.3 luminous intensity as a benchmark 2.3.1 luminous intensity of the reference for the preservation of luminous intensity of the unit value and international comparison, and through the work of all State delivers luminous intensity value. Its luminous intensity value range (90 ~ 1200) cd. 2.3.2 luminous intensity of the reference standard device by the distribution temperature of 2856K, 2353K two groups of high-stability luminous intensity Degree of sub-reference lamps, each lamp group of not less than 7 lights. 2.3.3 Luminous Intensity The extended uncertainty of the secondary datum is. U = 0.28%, k = 2.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 2034-2005_English be delivered?

Answer: Upon your order, we will start to translate JJG 2034-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 2034-2005_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 2034-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 2034-2005?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 2034-2005 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.