JJG 183-2017: Standard Capacitors
Status: Valid

JJG 183: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 183-2017English489 Add to Cart 4 days [Need to translate] Standard Capacitors Valid JJG 183-2017
JJG 183-2004EnglishRFQ ASK 3 days [Need to translate] The locomotive electrical measurement remote pressure gauge VRof JJG 183-2004
JJG 183-1992English639 Add to Cart 3 days [Need to translate] Verification Regulation of Standard Capacitors Obsolete JJG 183-1992
JJG 183-1978EnglishRFQ ASK 3 days [Need to translate] V.R. of Standard Capacitors Obsolete JJG 183-1978

PDF similar to JJG 183-2017


Standard similar to JJG 183-2017

JJF 1234   JJG 229   JJG 376   JJG 892   JJG 843   JJG 189   

Basic data

Standard ID JJG 183-2017 (JJG183-2017)
Description (Translated English) Standard Capacitors
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Classification of International Standard 17.220
Word Count Estimation 21,275
Date of Issue 2017-09-26
Date of Implementation 2018-03-26
Older Standard (superseded by this standard) JJG 183-1992
Quoted Standard JJF 1023-1991; GB 9090-1988
Regulation (derived from) General Administration of State Quality Inspection Announcement 2017 No. 78
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the first verification, subsequent verification and in-service inspection of standard capacitors with a capacitance range of 0.001 pF to 10 mF and a frequency range of 20 Hz to 1 MHz.

JJG 183-2017: Standard Capacitors

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Standard Capacitor Verification Regulation) People's Republic of China National Metrological Verification Procedures Standard capacitor 2017-09-26 Posted 2018-03-26 implementation General Administration of Quality Supervision, Inspection and Quarantine released Standard capacitor verification procedures Replacing JJG 183-1992 Administrative Organization. National Electromagnetic Measurement Technical Committee Main drafting units. China Institute of Metrology Participated in the drafting unit. Cheng Kai spectrum Electronic Technology Co., Ltd Beijing Institute of Radio Metrology and Measurement The rules entrusted the National Electromagnetic Measurement Technical Committee responsible for the interpretation The main drafters of this procedure. Dai Dongxue (China Institute of Metrology) Wang Wei (China Institute of Metrology) Participate drafters. Jin Pan (Chengdu open spectrum Electronic Technology Co., Ltd.) Li Li (Beijing Institute of Radio Metrology and Measurement)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Terms and measurement units (1) 3.1 Capacitance (1) 3.2 Capacitor loss factor (1) 4 Overview (1) 5 measurement performance requirements (2) 5.1 indication error (2) 5.2 years of stability (2) 5.3 Deviations (3) 5.4 Accuracy level (3) 5.5 Capacitor dissipation factor (4) 6 General technical requirements (4) 7 measuring instruments control (4) 7.1 test conditions (4) 7.2 Measurement equipment and the main supporting equipment technical conditions (5) 7.3 test items (6) 7.4 Test Method (6) 7.5 test results of the treatment (8) 7.6 Verification Period (8) Appendix A Standard capacitor frequency characteristics of the measurement method (9) Appendix B Standard Capacitors 10μF or more to note (10) Appendix C Verifying the original recording format (12) Appendix D Certificate of Conformity/Certificate Result Page Layout (Page 2) (14) Appendix E Verification Certificate/Verification Result Notification Verification Result Page Style (Page 3) (15)

Introduction

The rules based on JJF1001-2011 "common measurement terms and definitions", JJF1002-2010 "national measurement Test procedures for the preparation of rules "and JJF1059.1-2012" measurement uncertainty assessment and presentation "preparation. This regulation is a revision of JJG 183-1992 "Standard Capacitor". Compared with JJG 183-1992, except for editing In addition to the editorial changes, the main technical changes of this regulation are as follows. --- Increase according to the classification of the standard capacitor accuracy level; --- Remove some unnecessary test items, such as temperature coefficient, insulation resistance, etc .; --- Capacitor test frequency range extended to 1MHz. This version of the previous version of the release is. --- JJG 183-1978; --- JJG 183-1992. Standard capacitor verification procedures

1 Scope

This procedure applies to the capacitor range 0.001pF ~ 10mF, the standard frequency range 20Hz ~ 1MHz capacitor The first test, follow-up test and use of inspection.

2 reference documents

The regulations reference the following documents. JJF1023-1991 Commonly used terms of electrical measurement (Trial) GB 9090-1988 standard capacitors For dated references, only the dated version applies to this edition; any undated reference The latest version (including all amendments) applies to this procedure.

3 Terms and measurement units

3.1 capacitance capacitance When the charges carried by the two conductors are the same or different sign, the magnitude of the charge is proportional to the potential difference between the two conductors. In the international single SI-bit system, the capacitor unit is Farah, F. Note. 1. The size of the capacitor, both with the two electrodes of the geometry, size and mutual position, but also with the dielectric capacitance Rate related. 2. The capacitor units often used in engineering are microfarads [pull] μF or pf [pull] pF. 3.2 capacitor dissipation factor dissipationfactorforcapacitors The capacitor dissipation factor is the loss tangent tan δ of the capacitor. In an alternating electric field, the capacitor losses power and The ratio of storage power loss factor, used to determine the quality of capacitors and media.

4 Overview

Standard capacitor is the verification of all levels of capacitance measuring instruments in kind. According to the different media materials, divided into gas Bulk media and solid media standard capacitors, commonly used gas medium with air, nitrogen, argon, etc., solid medium stone British, mica, ceramics, organic media materials, etc .; according to the measurement of different leads, divided into single-port coaxial, three-terminal, Four-terminal and five-terminal standard capacitors. The structure of the standard capacitor is divided into coaxial, flat type, winding type and multilayer type. Common coaxial and flat type Capacitor diagram shown in Figure 1. Among them. Figure 1 (a), l is the electrode length, d1 and d2 are internal and external electrodes Diameter; Figure 1 (b), d is the distance between the plates.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 183-2017_English be delivered?

Answer: Upon your order, we will start to translate JJG 183-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 183-2017_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 183-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 183-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 183-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.