US$599.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1186-2022: Verification Equipment for DC Electrical Energy Meters Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1186-2022 | English | 599 |
Add to Cart
|
5 days [Need to translate]
|
Verification Equipment for DC Electrical Energy Meters
| Valid |
JJG 1186-2022
|
Standard similar to JJG 1186-2022 JJG 1193 JJG 1192 JJF 1186
Basic data Standard ID | JJG 1186-2022 (JJG1186-2022) | Description (Translated English) | Verification Equipment for DC Electrical Energy Meters | Sector / Industry | Metrology & Measurement Industry Standard | Word Count Estimation | 27,227 | Date of Issue | 2022-09-26 | Date of Implementation | 2023-03-26 | Issuing agency(ies) | State Administration for Market Regulation |
JJG 1186-2022: Verification Equipment for DC Electrical Energy Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Equipment for DC Electrical Energy Meters
National Metrology Verification Regulations of the People's Republic of China
DC watt-hour meter verification device
Released on 2022-09-26
2023-03-26 Implementation
Released by the State Administration for Market Regulation
Verification Regulations for Verification Device of DC Electric Energy Meter
Responsible unit. National Electromagnetic Metrology Technical Committee
Main drafting unit. Hunan Institute of Metrology and Testing
Changsha Tianheng Measurement and Control Technology Co., Ltd.
Shandong Institute of Metrology
Participating in the drafting unit. State Grid Hunan Electric Power Co., Ltd. Power Supply Service Center (Metering Center)
Huaihua Jiannan Electronic Technology Co., Ltd.
This regulation entrusts the National Electromagnetic Metrology Technical Committee to be responsible for interpretation
The main drafters of this regulation.
Song Wentao (Hunan Institute of Metrology and Testing)
Xie Xiaojun (Hunan Institute of Metrology and Testing)
Zhou Xinhua (Changsha Tianheng Measurement and Control Technology Co., Ltd.)
Participating drafters.
Li Qingxian (Hunan Institute of Metrology and Testing)
Yangmei (Shandong Institute of Metrology)
Chen Xiangqun [Power Supply Service Center (Metering Center) of State Grid Hunan Electric Power Co., Ltd.]
Yang Huijun (Huaihua Jiannan Electronic Technology Co., Ltd.)
Table of contents
Introduction (Ⅱ)
1 Scope(1)
2 References(1)
3 terms(1)
4 Overview(1)
5 Metrological performance requirements (1)
5.1 Basic error of electric energy (1)
5.2 Measurement repeatability(2)
5.3 Standards(2)
5.4 Output and display of energy value (3)
5.5 Error and display of monitoring value (3)
5.6 Device output(3)
5.7 Consistency of Multiple Outputs(4)
5.8 Load effects(4)
5.9 Poor stability (4)
6 General technical requirements (5)
6.1 Appearance(5)
6.2 Structure (5)
6.3 Output terminal and error display (5)
6.4 Insulation(5)
6.5 Thermal stability(5)
7 Measuring Instrument Control(5)
7.1 Initial verification, subsequent verification and in-use inspection(5)
7.2 Test conditions (6)
7.3 Verification items (6)
7.4 Verification method (7)
7.5 Processing of test results (11)
7.6 Verification cycle (11)
Appendix A Verification Original Record Format (12)
Appendix B Format of the inner pages of the verification certificate/test result notification (page 2) (16)
Appendix C Verification Certificate/Verification Result Notice Verification Result Page Sample (Page 3) (17)
Introduction
JJF1002 "Rules for Writing National Metrology Verification Regulations", JJF1001 "General Metrology Terms and Definitions" and
JJF1059.1 "Assessment and Expression of Measurement Uncertainty" together constitute the basic series of regulations supporting the formulation of this regulation.
Fan. This regulation stipulates the main technical requirements, verification items and verification methods of the DC electric energy meter verification device.
This regulation is published for the first time.
Verification Regulations for Verification Device of DC Electric Energy Meter
1 Scope
This regulation applies to the initial verification, follow-up verification and in-use inspection of the DC electric energy meter verification device.
2 References
This procedure references the following documents.
JJG 842-2017 Verification Regulations for Electronic DC Energy Meter
For dated references, only the dated version applies to this regulation; for undated references
document, its latest version (including all amendments) applies to this regulation.
3 terms
The following terms and definitions apply to this procedure.
3.1 Ripple ripple wave
In a DC voltage or current, the AC component superimposed on the DC.
Note. The size of the ripple is usually represented by the effective value or peak value, and this procedure is represented by the effective value.
3.2 ripple coefficient ripplecoefficient
The ratio of the effective value of the output ripple voltage (current) to the output DC voltage (current), usually in percentage
(%)express.
3.3 control limit control limit
Generally refers to the frequent use, which is more representative of the metering performance of the device, and is usually used as an evaluation of the metering performance by the manufacturer and the user.
The main reference limit for adjustment and long-term assessment.
4 Overview
The DC watt-hour meter verification device (hereinafter referred to as the device) is used for the verification of the DC watt-hour meter.
combination of appliances that supply energy and are capable of measuring this energy. Usually, the device consists of an electric energy measurement standard (standard electric energy meter, power
Rate meter, electric energy converter) or electric energy measuring circuit, limit expansion circuit, electric parameter monitoring circuit (or instrument), auxiliary
Auxiliary measurement circuit, communication interface, and electric energy output circuit. The current output mode of the device includes. current direct
Output mode, small signal voltage output mode.
5 Metering performance requirements
5.1 Basic error of electric energy
5.1.1 The basic error of electric energy refers to the measurement error of the electric energy of the device under the reference condition, which is determined by the test and used relative
error representation.
5.1.2 The accuracy level of the device is divided according to the accuracy level of electric energy measurement. When the current output mode of the device is both
For direct current output type and small signal voltage output type, the accuracy grades shall be marked respectively.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1186-2022_English be delivered?Answer: Upon your order, we will start to translate JJG 1186-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1186-2022_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1186-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|