US$739.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1097-2014: Verification Regulation of Phoropters(Eye Chart Included) Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1097-2014 | English | 739 |
Add to Cart
|
6 days [Need to translate]
|
Verification Regulation of Phoropters(Eye Chart Included)
| Valid |
JJG 1097-2014
|
PDF similar to JJG 1097-2014
Basic data Standard ID | JJG 1097-2014 (JJG1097-2014) | Description (Translated English) | Verification Regulation of Phoropters(Eye Chart Included) | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A60 | Classification of International Standard | 17.180 | Word Count Estimation | 32,371 | Date of Issue | 6/15/2014 | Date of Implementation | 9/15/2014 | Quoted Standard | GB 11533-2011; ISO 10341-2012 | Adopted Standard | ISO 10341-2012, MOD | Regulation (derived from) | The State Administration of Quality Supervision, Inspection and Quarantine Notice No. 64 of 2014 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard specifies the phoropter and far vision chart (not included in the reading eye chart) the initial verification, subsequent verification and use of checks. |
JJG 1097-2014: Verification Regulation of Phoropters(Eye Chart Included)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Phoropters (Eye Chart Included)
State verification procedures People's Republic of China
Integrated refractometer (including eye chart)
Phoropters (EyeChartIncluded)
Issued on. 2014-06-15
2014-09-15 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Integrated refractometer (including eye chart)
Verification Regulation
Phoropters (EyeChartIncluded
Focal point. the National Technical Committee on Medical Measurement
The main drafting units. China Institute of Metrology
Participated in the drafting unit. Hangzhou quality technical supervision detection hospital
Zhejiang Institute of Metrology
Shanghai-Bo Precision Instrument Co., Ltd.
Hangzhou precision optical instruments to fly Manufacturing Co., Ltd.
This procedure entrust the National Technical Committee is responsible for interpreting medical measurement
The main drafters of this procedure.
Zhang Ji Yan (China Institute of Metrology)
High Bright (China Institute of Metrology)
Drafters participate.
Liu Wenli (China Institute of Metrology)
Zheng Ru (Hangzhou Quality and Technical Supervision and Inspection Institute)
Wang Wenxing (Zhejiang Institute of Metrology)
Hu Chi-bing (Shanghai-Bo Precision Instrument Co., Ltd.)
Murdoch just (Hangzhou precision optical instruments to fly Manufacturing Co., Ltd.)
table of Contents
Introduction (Ⅲ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
3.1 integrated refractometer (1)
3.2 reference plane (1)
3.3 After the vertex (1)
3.4 prism (1)
3.5 optotype (1)
3.6 visual acuity chart (1)
3.7 Perspective (2)
Visual target growth rate of 3.8 (2)
3.9 Vision Records (2)
3.10 Design Distance (2)
3.11 Check the distance (2)
3.12 standard distance (2)
4 Overview (2)
4.1 Composition and use (2)
4.2 principle and structure (3)
5 metering performance requirements (4)
5.1 integrated refractometer (4)
5.2 visual acuity chart (5)
6 General Requirements (6)
6.1 integrated refractometer (6)
6.2 visual acuity chart (7)
7 control of measuring instruments (7)
7.1 Verification condition (7)
7.2 The main test equipment (7)
7.3 Verification Project (7)
7.4 test methods (8)
7.5 Verification Results processing (11)
7.6 test cycle (12)
Appendix A distant vision statement "E" type, as the standard data (13)
Style eye chart different calculation method B, as the standard-sized appendix (14)
Appendix C phoropter top power measuring device (15)
Appendix D integrated refractometer original record format recommended (16)
Appendix E chart format recommended by the original records (19)
Appendix F integrated refractometer test certificates/test results notice (inside) Recommended format (20)
Appendix G eye chart test certificates/test results notice (inside) Recommended format (23)
Introduction
JJF1002-2010 "national verification procedures write rules", JJF1001-2011 "common terminology and measurement
The definition of "together constitute the support of the protocol development of the basic family of specifications.
The combination of integrated refractometer develop procedures and visual status of the domestic table and the special requirements of the application, modify, adopt
ISO 10341.2012 "ophthalmic instruments optometry head" (Ophthalmicinstruments-Refractorheads) and
GB 11533-2011 "standard vision chart."
This procedure is the first release.
Integrated refractometer (including eye chart) test procedures
1 Scope
The order applies to integrated refractometer and far vision chart (not included in the reading eye chart) the initial verification, follow-up inspection
And given the use of checks.
2. References
This procedure refers to the following documents.
GB 11533-2011 standard vision chart
ISO 10341-2012 ophthalmic instruments optometry head (Ophthalmicinstruments-Refractorheads)
For dated references, only the dated edition applies to this procedure; undated reference documents
Member, the latest edition (including any amendments) applies to this procedure.
3 terminology and units of measurement
The following terms and definitions apply to this procedure.
3.1 phoropter phoropter
Also known as the head of optometry (refractorhead), commonly known as bovine lung or head, it is to check with the ball optometry lenses, lenticular
Films, prism sheets and various auxiliary lenses and various adjustment components integrated in one visual inspection equipment, through different internal mirror
Superimposed on the disc combination lenses, eye examination to achieve the refractive status and visual function.
3.2 reference plane referenceplane
Top with integrated refractometer power measuring device reference plane of the integrated refractometer for checking the time on on this plane
Metrological performance spherical degree of integrated refractometer, cylinder Indication errors, etc. for examination.
Note. The method for determining phoropter reference plane generally given by the manufacturer. If manufacturers do not specifically pointed out that the use of integrated test
The 15.00m-1 spectrometer ball lenses to determine the position of the reference plane.
3.3 After the vertex backvertexpower
After the lens near the axis in meters measured at the top of the reciprocal of the focal length. The unit is the reciprocal meter (m-1).
Note. The top paraxial focal length is the distance after the paraxial focus from the vertex to the lens.
3.4 prism prismaticpower
Measure the light deviated by a predetermined point on the lens produced (usually the center of the lens) later. In centimeters per
M (cm/m).
3.5, as the standard optotype
Determination of vision with a variety of text, numbers, or graphics.
NOTE. Depending on the measured object or situation, you can choose one or more visual target.
3.6 eye chart eyechart
By the arrangement according to certain rules of composition, as the standard measurement for the human eye vision chart.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1097-2014_English be delivered?Answer: Upon your order, we will start to translate JJG 1097-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1097-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1097-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|