US$309.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1040-2008: Verification Regulation of Digital Measuring Device for Optical Interference Methane Detector Status: Valid JJG 1040: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1040-2008 | English | 309 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Digital Measuring Device for Optical Interference Methane Detector
| Valid |
JJG 1040-2008
|
JJG 1040-1993 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Technical Specification of Measurement Assurance pro gram for Radio Attenuation
| Obsolete |
JJG 1040-1993
|
PDF similar to JJG 1040-2008
Basic data Standard ID | JJG 1040-2008 (JJG1040-2008) | Description (Translated English) | Verification Regulation of Digital Measuring Device for Optical Interference Methane Detector | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A60 | Classification of International Standard | 17.180 | Word Count Estimation | 13,126 | Date of Issue | 2008-03-25 | Date of Implementation | 2008-06-25 | Regulation (derived from) | ?AQSIQ Announcement 2008 No.35; | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to non-metallic tension, pressure and universal testing machine (hereinafter referred to as test machine) the initial verification, testing and use of subsequent testing. Nonmetallic tension, pressure and universal testing machine includes a small load testing machine, small force value tester. And leather, paper, rubber, plastics, fiber and other non-metallic materials testing machine. |
JJG 1040-2008: Verification Regulation of Digital Measuring Device for Optical Interference Methane Detector ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Digital Measuring Device for Optical Interference Methane Detector
State verification procedures People's Republic of China
Digital optical interference methane measuring Calibrator
Posted 2008-03-25
2008-06-25 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Digital optical interference methane
Determination Calibrator Verification Regulation
DeviceforOp
The regulations by the State Administration of Quality Supervision, Inspection and Quarantine, 2008 March 25 ratification and
From June 25, 2008 implementation.
Focal point. the National Technical Committee of pressure measurement
Drafting units. China Testing Technology Research Institute
Liaoning Provincial Institute of Metrology
Shaanxi Provincial Institute of Metrology
Henan Institute of Metrology
Shanxi measurement supervision and verification tests
Participated in the drafting unit. Air pressure test too Taiyuan Technology Co., Ltd.
National Mine Safety metering station sub-station in Urumqi
Sichuan Aerospace Institute of Metrology
The measurement procedure commissioned the National Technical Committee is responsible for interpreting pressure
The main drafters of this procedure.
Li Zubin (China Testing Technology Research Institute)
Zhang Zijian (Liaoning Provincial Institute of Metrology)
Wang Hongyan (Shaanxi Provincial Institute of Metrology)
Xiao-full (Henan Institute of Metrology)
Zhang Jinliang (Shanxi measurement supervision and verification tests)
Drafters participate.
Gan Rong (China Testing Technology Research Institute)
Yan Jinping (Taiyuan Taihang Stress Test Technology Co., Ltd.)
Dong Zhibin (National Mine Safety Urumqi metering station sub-station)
Li Lin (Sichuan Aerospace Metrology Institute)
table of Contents
1 Scope (1)
2 Overview (1)
3 metering performance requirements (1)
3.1 indication error (1)
3.2 Return error (2)
3.3 Zero drift (2)
Tightness 3.4 (2)
3.5 Temperature error (2)
4 General Requirements (2)
4.1 Appearance (2)
4.2 Insulation Resistance (2)
5 control of measuring instruments (2)
5.1 verification Conditions (2)
5.2 Verification Project (2)
5.3 Verification Methods (3)
5.4 test results processing (4)
5.5 test cycle (4)
Appendix A Calibrator test recording format (5)
Appendix B test certificate page format (6)
Appendix C test results in the notice page format (7)
Appendix D of methane concentration and pressure, the temperature corresponding to the calculated relation (8)
Digital optical interference methane measuring Calibrator Verification Regulation
1 Scope
The order applies to the measurement range of the volume fraction of 0 ~ 10% CH4 and 0 ~ 100% CH4 digital optical interference
Methane measuring Calibrator (hereinafter referred to as the Calibrator) initial verification, subsequent verification and in-service inspection.
2 Overview
Calibrator A block diagram shown in Figure 1, respectively, by a pressure sensor, a temperature sensor detects light interference A
Alkyl measuring chamber measuring pressure and test the ambient temperature, the pressure is detected, the temperature is converted into an electrical signal. By letter
Amplification processing unit, and the A/D conversion, and then calculated directly by a microprocessor corresponding to the pressure, body temperature
Concentration of methane fraction represented and displayed on the monitor, enabling the optical interference of methane detector test.
Block diagram of Figure 1 Calibrator work
Calibrator can be divided into direct and non-direct reading reading type.
a) Direct-reading type Calibrator principle is the collected pressure and temperature values calculated directly corresponding to the pressure,
Methane concentration test point temperature value expressed in volume fraction, and displayed on the display.
b) Non-Direct-reading type Calibrator principle is to only collect pressure, according to test ambient temperature, and then calculate
Corresponding to the pressure, temperature test point concentration of methane by volume expressed as a fraction.
3 metering performance requirements
3.1 Indication error
Calibrator to represent the volume fraction of the measurement range and the maximum permissible error in Table 1, the Calibrator to measure pressure expressed
The scope and amount of the maximum permissible error in Table 2.
Table 1 Calibrator to represent the volume fraction of the measurement range and the maximum permissible error
Measurement range /% CH4 0 ~ 10 0 ~ 100
The maximum permissible error /% CH4 ± 0.016 ± 0.12
Table 2 indicates Calibrator pressure measurement range and the maximum permissible error
With respect to the concentration of methane 0 ~ 10% CH4 0 ~ 100% CH4
Measurement range/kPa 0 ~ 8 0 ~ 60
The maximum permissible error/kPa ± 0.008 ± 0.06
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1040-2008_English be delivered?Answer: Upon your order, we will start to translate JJG 1040-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1040-2008_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1040-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 1040-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 1040-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|