JJG 1028-2024: Verification Regulation of X-ray Radiation Source for Radiotherapy Simulators
Status: Valid

JJG 1028: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1028-2024English359 Add to Cart 4 days [Need to translate] Verification Regulation of X-ray Radiation Source for Radiotherapy Simulators Valid JJG 1028-2024
JJG 1028-2007English369 Add to Cart 3 days [Need to translate] Verification Regulation of X-ray Radiation Source for Radiotherapy Simulating Localization Valid JJG 1028-2007
JJG 1028-1991EnglishRFQ ASK 3 days [Need to translate] Standard Methed for Using the Silver Dichromate Dosimeter to Measure γ-ray Absorbed Dose in Water Obsolete JJG 1028-1991

Basic data

Standard ID JJG 1028-2024 (JJG1028-2024)
Description (Translated English) Verification Regulation of X-ray Radiation Source for Radiotherapy Simulators
Sector / Industry Metrology & Measurement Industry Standard
Word Count Estimation 17,156
Date of Issue 2024-09-18
Date of Implementation 2025-03-18
Issuing agency(ies) State Administration for Market Regulation

JJG 1028-2024: Verification Regulation of X-ray Radiation Source for Radiotherapy Simulators

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
National Metrology Verification Regulations of the People's Republic of China Radiotherapy simulation positioning X-ray Radiation source verification procedures Released on 2024-09-18 2025-03-18 Implementation The State Administration for Market Regulation issued Radiotherapy simulation positioning X-ray Radiation source verification procedures Replace JJG 1028-2007 Responsible unit. National Technical Committee for Ionizing Radiation Metrology Main drafting unit. Hebei Provincial Institute of Metrology Supervision and Inspection Shenzhen Institute of Metrology and Quality Inspection Participating in the drafting. Hebei Zhongmo Medical Equipment Technology Co., Ltd. Shandong Xinhua Medical Instrument Co., Ltd. This regulation is entrusted to the National Technical Committee for Ionizing Radiation Metrology for interpretation. The main drafters of this regulation are. Cai Zonglin (Hebei Provincial Institute of Metrology Supervision and Inspection) Zhou Yingchun (Shenzhen Institute of Metrology and Quality Inspection) Li Wenbo (Hebei Provincial Institute of Metrology Supervision and Inspection) Participating drafters. Sun Chaoyang (Hebei Zhongmo Medical Equipment Technology Co., Ltd.) Ding Meng (Hebei Provincial Institute of Metrology Supervision and Inspection) Li Zhiyong (Shandong Xinhua Medical Instrument Co., Ltd.)

Table of contents

Introduction (II) 1 Scope(1) 2 References(1) 3 Terminology and units of measurement (1) 3.1 Terminology (1) 3.2 Units of measurement (2) 4 Overview(2) 5 Metrological performance requirements (2) 5.1 Air kerma rate of radiant output (2) 5.2 X-ray tube voltage (2) 5.3 Quality of radiant output (2) 5.4 Spatial resolution (2) 5.5 Low contrast resolution (3) 5.6 Isocenter indication offset (3) 5.7 Defining the offset between the radiation beam axis and the isocentre (3) 5.8 Consistency between defined radiation fields and defined light fields (3) 5.9 Source-skin distance indication deviation (3) 6 General technical requirements (3) 6.1 Appearance and logo(3) 6.2 Technical Documents (3) 7 Measuring instrument control (3) 7.1 Verification conditions (3) 7.2 Verification Items (4) 7.3 Verification methods (5) 7.4 Processing of test results (7) 7.5 Verification cycle (8) Appendix A Recommended format for original verification records (9) Appendix B Recommended format for the inner pages of the certificate (10) Appendix C Technical requirements for isocenter detection device (11)

Introduction

JJF1002 "Rules for the Preparation of National Metrology Verification Procedures", JJF1001 "General Metrology Terms and Definitions", JJF1059.1 "Evaluation and Expression of Uncertainty in Measurement" together constitute the basic series of specifications for the revision of this regulation. This regulation is a revision of JJG 1028-2007 "X-ray Radiation Source Positioning for Radiotherapy Simulation". Compared with JJG 1028-2007, in addition to editorial revisions, the main technical content of this regulation has changed as follows. --- Added the definitions of image receiver, focus-image receiver distance and field of view; --- Added the requirements for X-ray tube voltage and related content; --- Added low contrast resolution requirements and related content; --- Increased spatial resolution requirements for flat panel detectors; --- Deleted the requirements for electrical machinery and protective performance; --- Added the half-value layer measurement method of radiation output quality and related content. The previous versions of this regulation are as follows. ---JJG 1028-2007. Radiotherapy simulation positioning X-ray Radiation source verification procedures

1 Scope

This procedure applies to the initial inspection of the X-ray radiation source used for radiotherapy simulation positioning before or during radiotherapy. The working voltage of the high voltage generator shall not exceed 400kV. This practice does not apply to X-ray radiation sources that use computed tomography (CT) simulation positioning technology.

2 References

This specification refers to the following documents. JJG 744 Medical diagnostic X-ray radiation source JJF1001 General metrological terms and definitions JJF1035 Ionizing radiation measurement terms and definitions GB/T 10149-1998 Terminology and symbols for medical X-ray equipment GB/T 17856-1999 Performance and test methods of radiotherapy simulators WS76-2020 Quality Control Test Specification for Medical X-ray Diagnostic Equipment YY/T 1407-2016 Radiotherapy simulation positioning machine imaging system performance and test methods For any referenced document with a date, only the version with the date is applicable to this Regulation; for any referenced document without a date, The latest version (including all amendments) shall apply to this regulation.

3 Terminology and units of measurement

3.1 Terminology The terms and definitions defined in JJF1001, JJF1035 and GB/T 10149-1998 and the following terms and definitions apply to this Regulations. 3.1.1 Kerma The total initial kinetic energy of all charged particles released by uncharged ionized particles in a substance of mass dm is and dEtr divided by dm. 3.1.2 Kermarate The increase in kerma dK during time dt is divided by dt. 3.1.3 Half-value layer; HVL The thickness of the attenuation layer that reduces the radiation of a unidirectional particle stream to half of its initial value. In radiotherapy, the distance from the radiation source surface to the incident surface.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1028-2024_English be delivered?

Answer: Upon your order, we will start to translate JJG 1028-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1028-2024_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1028-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 1028-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 1028-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.