US$499.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 2059-2023: Calibration Specification for Capsule Altitude Gauges, Airspeed Gauges and Mach Gauges Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 2059-2023 | English | 499 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Capsule Altitude Gauges, Airspeed Gauges and Mach Gauges
| Valid |
JJF 2059-2023
|
Standard similar to JJF 2059-2023 JJF 2052 JJF 2051 JJG 2059
Basic data Standard ID | JJF 2059-2023 (JJF2059-2023) | Description (Translated English) | Calibration Specification for Capsule Altitude Gauges, Airspeed Gauges and Mach Gauges | Sector / Industry | Metrology & Measurement Industry Standard | Word Count Estimation | 24,271 | Date of Issue | 2023-06-30 | Date of Implementation | 2023-12-30 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 2059-2023: Calibration Specification for Capsule Altitude Gauges, Airspeed Gauges and Mach Gauges ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
National Metrology Technical Specifications of the People's Republic of China
Diaphragm altimeter, airspeed indicator,
Mach number meter calibration specifications
Published on 2023-06-30
Implemented on 2023-12-30
Released by the State Administration for Market Regulation
Diaphragm altimeter, airspeed indicator,
Mach number meter calibration specifications
Responsible unit. National Pressure Measurement Technical Committee
Main drafting unit. Beijing Great Wall Measurement and Testing Technology Institute
Unit participating in the drafting. AVIC Taiyuan Aviation Instrument Co., Ltd.
AVIC Guizhou Aircraft Co., Ltd.
92493 Troop Metrology Testing Center
The National Pressure Measurement Technical Committee is entrusted with the interpretation of this specification.
The main drafters of this specification.
Li Xinwu (Beijing Great Wall Measurement and Testing Technology Research Institute)
Sheng Xiaoyan (Beijing Great Wall Measurement and Testing Technology Research Institute)
Li Qun (Beijing Great Wall Measurement and Testing Technology Research Institute)
Participating drafters.
Zhang Weihong (AVIC Taiyuan Aviation Instrument Co., Ltd.)
Peng Haibo (AVIC Guizhou Aircraft Co., Ltd.)
Bai Xu (92493 Force Measurement and Testing Center)
Wang Yang (Beijing Great Wall Measurement and Testing Technology Research Institute)
Table of contents
Introduction(Ⅱ)
1 Scope(1)
2 Cited documents(1)
3 Terminology and units of measurement(1)
3.1 Terminology(1)
3.2 Unit of measurement(1)
4 Overview(2)
5 Measuring characteristics(2)
5.1 Zero position(2)
5.2 Air tightness(2)
5.3 Indication error(3)
5.4 Return error(4)
5.5 Tap displacement(4)
5.6 Position error(4)
6 Calibration conditions(5)
6.1 Environmental conditions(5)
6.2 Standard device for calibration (5)
7 Calibration items and calibration methods (5)
7.1 Preparation before calibration(5)
7.2 Zero position check(5)
7.3 Air tightness inspection(5)
7.4 Indication error calibration(6)
7.5 Return error calibration(7)
7.6 Tap displacement calibration(7)
7.7 Position error calibration(7)
8 Calibration results(8)
9 Recalibration time interval(8)
Appendix A Calibration record format of capsule altimeter, airspeed indicator and Mach number indicator (9)
Appendix B Internal page format of calibration certificate for capsule altimeter, airspeed indicator and Mach number indicator (10)
Appendix C Calibration uncertainty evaluation of capsule altimeter (11)
Appendix D Calibration Uncertainty Evaluation of Diaphragm Airspeed Indicator (14)
Appendix E Calibration Uncertainty Evaluation of Diaphragm Mach Number Meter (16)
Introduction
JJF 1071 "Rules for Writing National Measurement Calibration Specifications", JJF 1001 "General Measurement Terms and Definitions",
Common to JJF 1008 "Terms and Definitions of Pressure Measurement" and JJF 1059.1 "Evaluation and Expression of Measurement Uncertainty"
It constitutes the basic series of specifications that support the formulation of this specification.
This specification provides specific calibration conditions and calibration items for the measurement characteristics of capsule altimeters, airspeed indicators, and Mach number meters.
purpose and calibration method.
This specification mainly refers to JJG52-2013 "Elastic Element Type General Pressure Gauge, Pressure Vacuum Gauge and Vacuum Gauge Inspection"
Regulations", HB6127-1986 "Flight Atmospheric Parameters", HB6552-1991 "Civil Aircraft Barometric Altitude"
"Minimum Performance Requirements for Airspeed Indicators", HB6551-1991 "Minimum Performance Requirements for Civil Aircraft Airspeed Indicators", HB7826-
2008 "General Specifications for Airspeed Indicators", HB7828-2008 "General Specifications for Mach Number Indicators", BS2G115-1956
aircraft) and other documents related content will be formulated.
This specification is released for the first time.
Diaphragm altimeter, airspeed indicator,
Mach number meter calibration specifications
1 Scope
This calibration specification is applicable to the calibration of capsule altimeters, airspeed indicators, and Mach number indicators used in aviation.
2 cited documents
This specification references the following documents.
JJG52-2013 Calibration regulations for elastic element type general pressure gauges, pressure vacuum gauges and vacuum gauges
JJF 1008-2008 Pressure measurement terms and definitions
HB6127-1986 Flight atmospheric parameters
HB6551-1991 Minimum performance requirements for civil aircraft airspeed indicators
HB6552-1991 Minimum performance requirements for civil aircraft barometric altimeters
HB7826-2008 General specifications for airspeed indicators
HB7828-2008 General Specification for Mach Number Tables
foraircraft)
aircraft)
For dated references, only the dated version applies to this specification; for undated references, only the dated edition applies.
The latest version (including all modification orders) shall apply to this specification.
3 Terminology and units of measurement
3.1 Terminology
The membrane box is used as a sensitive element to measure the atmospheric static pressure, and the measured static pressure is converted into
An instrument that converts pressure into altitude.
Use the diaphragm as a sensitive element to measure atmospheric static pressure and total pressure, and use the changes between airspeed and atmospheric static pressure and total pressure.
An instrument that regularly converts measured static pressure and total pressure into airspeed.
3.1.3 CapsuleMachgauges
The diaphragm is used as a sensitive element to measure the atmospheric static pressure and total pressure, and the change between Mach number and atmospheric static pressure and total pressure is used.
An instrument that converts the measured static pressure and total pressure into Mach number according to the chemical law.
3.2 Unit of measurement
The measurement unit used by the altimeter is meters (m) or kilometers (km).
The unit of measurement used by the airspeed indicator is kilometers per hour (km/h).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 2059-2023_English be delivered?Answer: Upon your order, we will start to translate JJF 2059-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 2059-2023_English with my colleagues?Answer: Yes. The purchased PDF of JJF 2059-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|