US$649.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1847-2020: (Calibration specification for electronic balance) Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1847-2020 | English | 649 |
Add to Cart
|
6 days [Need to translate]
|
(Calibration specification for electronic balance)
| Valid |
JJF 1847-2020
|
PDF similar to JJF 1847-2020
Basic data Standard ID | JJF 1847-2020 (JJF1847-2020) | Description (Translated English) | (Calibration specification for electronic balance) | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Word Count Estimation | 28,240 | Date of Issue | 2020-07-02 | Date of Implementation | 2021-01-02 | Regulation (derived from) | Announcement No. 29 (2020) of the State Administration for Market Regulation | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1847-2020: (Calibration specification for electronic balance)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Calibration specification for electronic balance)
National Metrology Technical Specifications of the People's Republic of China
Calibration specification for electronic balance
2020-07-02 released
2021-01-07 implementation
Issued by the State Administration for Market Regulation
Calibration specification for electronic balance
Focal point. National Technical Committee of Quality Density Measurement
Main drafting unit. China Institute of Metrology
Shanghai Institute of Metrology and Testing Technology
METTLER TOLEDO Instruments (Shanghai) Co., Ltd.
Participating in the drafting. METTLER TOLEDO International Trade (Shanghai) Co., Ltd.
Yunnan Institute of Metrology and Testing Technology
Xinjiang Uygur Autonomous Region Metrology and Testing Institute
This specification entrusts the National Quality Density Measurement Technical Committee to be responsible for the interpretation
Main drafter.
Hu Manhong (China Institute of Metrology)
Su Yi (Shanghai Institute of Metrology and Testing Technology)
Ge Tianping (Mettler-Toledo Instruments (Shanghai) Co., Ltd.)
Participating drafters.
Li Tongyang (Mettler-Toledo International Trading (Shanghai) Co., Ltd.)
Huang Jian (Yunnan Institute of Metrology and Testing Technology)
Guo Rui (Xinjiang Uygur Autonomous Region Metrology and Testing Research Institute)
table of Contents
Introduction (Ⅱ)
1 scope (1)
2 Reference documents (1)
3 Terms and measurement units (1)
3.1 Term (1)
3.2 Symbol table (1)
3.3 Unit of measurement (2)
4 Overview (2)
4.1 Principle (2)
4.2 Purpose (3)
5 Metering characteristics (3)
6 Calibration conditions (3)
6.1 Standard weights (3)
6.2 Alternative loads (4)
6.3 Other related measuring instruments for measurement (4)
6.4 Calibration environmental conditions (4)
6.5 Indication (4)
7 Calibration items and calibration methods (4)
7.1 Calibration items (4)
7.2 Calibration method (4)
8 Calibration results (6)
8.1 Indication error measurement results (6)
8.2 Repeatability measurement results (6)
8.3 Load measurement results at different positions (7)
8.4 Calibration certificate (7)
9 Recheck interval (7)
Appendix A Evaluation of Uncertainty of Measurement Results of Electronic Balance (8)
Appendix B Alternative Load (11)
Appendix C Example of Uncertainty Evaluation of Measurement Results of Electronic Balance (16)
Appendix D Electronic balance calibration record format (example) (21)
Appendix E Inside page of electronic balance calibration certificate (example) (22)
Introduction
This specification is based on JJF 1071 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1059.1 "Measuring Uncertainty
Evaluation and Representation, refer to the International Recommendation R76-1 of the International Organization for Legal Metrology, Non-Automatic Weighing Instruments Part 1.Measurement
And technical requirements test, International Recommendation R76-2, Non-Automatic Weighing Apparatus Part 2.Test Report Format,
The European Union Calibration Guide No. 18 "Guide to Calibration of Non-Automatic Weighing Instruments", etc.
JJG1036-2008 "Electronic Balance" is used for the verification of electronic balances and gives the judgment of whether the electronic balance is qualified or not.
It belongs to the legal measurement requirements; this specification is used for the measurement requirements of other categories of electronic balances.
This specification provides the calibration conditions, calibration items, calibration methods and uncertainty evaluation methods and examples of electronic balances.
This specification is released for the first time.
Calibration specification for electronic balance
1 Scope
This specification applies to the calibration of various electronic balances.
2 Reference documents
This specification refers to the following documents.
JJG99 weight
JJG1036 Electronic Balance
JJF 1001 General measurement terms and definitions
JJF 1059.1 Evaluation and expression of measurement uncertainty
JJF 1181 Weighing instrument measurement terms and definitions
JJF 1229 Terms and Definitions of Mass Density Measurement
GB/T 23111 Non-automatic weighing instrument
GB/T 27418 Evaluation and Expression of Uncertainty in Measurement
OIMLR76-1 Non-automatic weighing instrument Part 1.Measurement and technical requirements test
OIMLR76-2 Non-automatic weighing instrument Part 2.Test report format
OIMLR111-1 E1, E2, F1, F2, M1-2, M2, M2-3 and M3 grade weights Part 1.Metrological technical requirements
OIMLR111-2 E1, E2, F1, F2, M1-2, M2, M2-3 and M3 grade weights Part 2.Measurement report form
EU Calibration Guide No. 18 Non-automatic Weighing Instrument Calibration Guide
For dated reference documents, only the dated version applies to this specification, and for undated reference documents,
The latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement
3.1 Term
Related terms refer to JJF 1001 "General Measurement Terms and Definitions", JJF 1181 "Weighing Apparatus Measurement Terms and
Definitions", JJF 1229 "Terms and Definitions of Mass Density Measurement".
3.2 Symbol table
The symbols listed in Table 1 apply to this specification. Table 2 shows the symbol subscript description.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1847-2020_English be delivered?Answer: Upon your order, we will start to translate JJF 1847-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1847-2020_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1847-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|