US$349.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1817-2020: Calibration Specification for Nucleic Acids Analyzers Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1817-2020 | English | 349 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Nucleic Acids Analyzers
| Valid |
JJF 1817-2020
|
PDF similar to JJF 1817-2020
Basic data Standard ID | JJF 1817-2020 (JJF1817-2020) | Description (Translated English) | Calibration Specification for Nucleic Acids Analyzers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A50 | Classification of International Standard | 17.020 | Word Count Estimation | 15,194 | Date of Issue | 2020 | Date of Implementation | 2020-04-17 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1817-2020: Calibration Specification for Nucleic Acids Analyzers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Nucleic Acids Analyzers
National Measurement Technical Specification of the People's Republic of China
Calibration Specification for Nucleic Acid Analyzer
2020-01-17 release
2020-04-17 Implementation
Issued by the State Administration of Market Supervision and Administration
Calibration Specification for Nucleic Acid Analyzer
Focal point. National Biometrics Technical Committee
Main drafting unit. China Academy of Metrology
Kaijie Enterprise Management (Shanghai) Co., Ltd.
Participating in the drafting unit. Chinese Academy of Agricultural Sciences
This specification entrusts the National Biometrics Technical Committee to interpret
The main drafters of this specification.
Dong Lianhua (Chinese Academy of Metrology)
Gao Yunhua (Chinese Academy of Metrology)
Cao Yan (Kajie Enterprise Management (Shanghai) Co., Ltd.)
Participating drafters.
Sui Zhiwei (Chinese Academy of Metrology)
Li Liang (Chinese Academy of Agricultural Sciences)
Wang Jing (Chinese Academy of Metrology)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Indication error (1)
5.2 Repeatability (1)
5.3 Fragment concentration linearity (2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Calibration reference materials and calibration equipment (2)
7 Calibration items and calibration methods (2)
7.1 Indication error (2)
7.2 Repeatability (3)
7.3 Concentration linearity (3)
8 Expression of calibration results (4)
9 Recalibration time interval (4)
Appendix A. Preparation and use of calibration reagents and solutions (5)
Appendix B. Reference Format for Original Calibration Records (6)
Appendix C. Reference Format of Internal Page of Calibration Certificate (7)
Appendix D Example of uncertainty assessment of concentration indication error (8)
Introduction
The preparation of this specification is based on the test of the main technical parameters of the nucleic acid analyzer, based on JJF 1071-2010
The provisions of "National Rules for the Preparation of Metrology Calibration", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Expression"
Make it.
This specification is the first release.
Calibration Specification for Nucleic Acid Analyzer
1 Scope
This specification is applicable to nucleic acid analyzers that analyze the length and concentration of nucleic acid fragments based on the principle of gel electrophoresis
Calibration, the length range of applicable nucleic acid fragments is (100 ~ 1000) bp, for nuclear
The calibration of the acid analyzer can be performed with reference to this specification. This specification does not apply to plate electrophoresis and genetic analyzers
calibration.
2 Reference documents
This specification refers to the following documents.
JJF 1265-2010 Biometric Terms and Definitions
For dated reference documents, only the dated version applies to this specification; for those without date references
The latest version (including all amendments) is applicable to this specification.
3 Terms and units of measurement
3.1 Fragment length
Represents the size of a nucleic acid fragment in units of nucleotides (nt) or base pairs (bp).
3.2 basepair (bp) basepair
Paired bases between two strands in nucleic acids. Such as adenine-thymine (AT) pair, adenine-uracil (A-
U), guanine-cytosine (GC) pair, guanine-uracil (GU) pair, etc. The number of base pairs characterizes DNA
Or the length of double-stranded RNA.
[JJF 1265-2010,4.41]
4 Overview
The nucleic acid analyzer (hereinafter referred to as the analyzer) is based on the principle of gel electrophoresis technology and converts double-stranded nucleic acids of different sizes.
The fragments are separated.In the presence of fluorescent dyes, the fluorescent dyes are embedded in the double-stranded nucleic acid to emit fluorescence.
Signal detection and analysis equipment can be qualitative and quantitative according to the electrophoresis time and fluorescence signal value of each nucleic acid fragment
analysis. The analyzer is usually composed of a sampler, capillary/microchip, fluorescence detection optical components, microcircuit control components,
Computer and application software, can be used for single and multiple PCR fragments, restriction enzyme digested DNA, etc.
Analysis of fragment length and concentration.
5 Metrological characteristics
5.1 Indication error
Fragment length indication error and fragment concentration indication error.
5.2 Repeatability
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1817-2020_English be delivered?Answer: Upon your order, we will start to translate JJF 1817-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1817-2020_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1817-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|