HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJF 1809-2020 English PDF

US$539.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1809-2020: Calibration Specification for Retroreflectometers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1809-2020English539 Add to Cart 5 days [Need to translate] Calibration Specification for Retroreflectometers Valid JJF 1809-2020

PDF similar to JJF 1809-2020


Standard similar to JJF 1809-2020

JJG 879   JJF 1106   JJG 810   JJF 1807   JJF 1814   JJF 1804   

Basic data

Standard ID JJF 1809-2020 (JJF1809-2020)
Description (Translated English) Calibration Specification for Retroreflectometers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A60
Classification of International Standard 17.180
Word Count Estimation 28,241
Date of Issue 2020
Date of Implementation 2020-04-17
Issuing agency(ies) State Administration for Market Regulation

JJF 1809-2020: Calibration Specification for Retroreflectometers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Calibration specification for retroreflective measuring instrument) National Metrology Technical Specifications of the People's Republic of China Calibration specification for retroreflectometer 2020-01-17 released 2020-04-17 implementation Issued by the State Administration for Market Regulation Calibration specification for retroreflectometer Focal point. National Technical Committee of Special Measuring Instruments for Highways Main drafting unit. Institute of Highway Science, Ministry of Transport Participated in the drafting. National Road and Bridge Engineering Testing Equipment Metering Station National Transportation Safety Facilities Quality Supervision and Inspection Center This specification entrusts the National Highway Special Measuring Instruments Metrology Technical Committee to be responsible for interpretation The main drafters of this specification. Su Wenying (Institute of Highway Science, Ministry of Transport) He Huayang (Institute of Highway Science, Ministry of Transport) Zhou Yishu (Institute of Highway Science, Ministry of Transport) Participating drafters. Leng Zhengwei (National Road and Bridge Engineering Testing Equipment Measuring Station) Bai Yuanyuan (National Transportation Safety Facilities Quality Supervision and Inspection Center) Wang Rui (National Road and Bridge Engineering Testing Equipment Measuring Station) Zhu Jing (National Road and Bridge Engineering Testing Equipment Measuring Station)

table of Contents

Introduction (Ⅱ) 1 scope (1) 2 Reference documents (1) 3 Terms and definitions (1) 3.1 Retroreflection (1) 3.2 Luminous intensity coefficient (1) 3.3 Retroreflective coefficient (1) 3.4 Retroreflective brightness coefficient (1) 4 Overview (1) 5 Measurement characteristics (2) 5.1 Indication error (2) 5.2 Measurement repeatability (2) 6 Calibration conditions (3) 6.1 Environmental conditions (3) 6.2 Calibration equipment (3) 7 Calibration items and calibration methods (3) 7.1 Indication error (3) 7.2 Measurement repeatability (3) 8 Calibration results (4) 8.1 Calibration record (4) 8.2 Calibration certificate (4) 8.3 Evaluation of Uncertainty of Calibration Results (4) 9 Recheck interval (4) Appendix A Calibration record form of retroreflective measuring instrument (5) Appendix B Calibration Certificate Information and Inner Page Style of Retroreflective Measuring Instrument (10) Appendix C Examples of Evaluation of Uncertainty in Calibration of Retroreflective Measuring Instruments (15)

Introduction

JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1059.1-2012 "Measuring Uncertainty "Assessment and Representation" together constitute a basic series of specifications that support the formulation of this specification. This specification is released for the first time. Calibration specification for retroreflectometer

1 Scope

This specification applies to the calibration of retroreflective measuring instruments.

2 Reference documents

This specification refers to the following documents. JJF 1059.1 Evaluation and expression of measurement uncertainty JJF 1796 Retroreflective Standard JT/T 688-2007 Retroreflective terminology JT/T 690 Retroreflector photometric performance test method For dated reference documents, only the dated version applies to this specification; for undated reference documents, The latest version (including all amendments) is applicable to this specification.

3 Terms and definitions

The terms and definitions defined in JT/T 688-2007 and below apply to this specification. 3.1 retroreflection Reflected light is a kind of reflection that returns from the opposite direction close to the incident light. [JT/T 688-2007,2.1] 3.2 RI coefficientofluminousintensity The luminous intensity (I) of the retroreflector in the observation direction is the same as the light on the plane perpendicular to the direction of the incident light. The ratio of illuminance (E┴), the unit is candela per lux (cd·lx-1). [JT/T 688-2007,2.34] 3.3 RA coefficientofretroreflection The ratio of the luminous intensity coefficient to the surface area of the retroreflector, the unit is candela per lux square meter (cd·lx-1·m-2). [JT/T 688-2007,2.35] 3.4 RL coefficientofretroreflectedluminance The ratio of the brightness L in the observation direction to the normal illuminance on the plane perpendicular to the direction of the incident light, the unit is Kande Pull lux per square meter (cd·m-2·lx-1). [JT/T 688-2007,2.37]

4 overview

The retroreflective measuring instrument is used to measure traffic safety such as traffic signs and reflective films, road traffic markings, and raised road signs. A portable optical device with full facility luminosity performance, used with retroreflective standard. The measurement principle is The alternative method specified in JT/T 690 can be used for both laboratory measurement and engineering site measurement.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1809-2020_English be delivered?

Answer: Upon your order, we will start to translate JJF 1809-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1809-2020_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1809-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.