US$529.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1715-2018: Program of Pattern Evaluation of Ion Chromatographs Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1715-2018 | English | 529 |
Add to Cart
|
4 days [Need to translate]
|
Program of Pattern Evaluation of Ion Chromatographs
| Valid |
JJF 1715-2018
|
PDF similar to JJF 1715-2018
Basic data Standard ID | JJF 1715-2018 (JJF1715-2018) | Description (Translated English) | Program of Pattern Evaluation of Ion Chromatographs | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Word Count Estimation | 23,215 | Date of Issue | 2018-06-25 | Date of Implementation | 2018-09-25 | Regulation (derived from) | State Administration of Markets, Announcement No. 13 of 2018 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1715-2018: Program of Pattern Evaluation of Ion Chromatographs---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Ion Chromatographs
National Metrology Technical Specification of the People's Republic
Ion Chromatography Type Evaluation Outline
Published on.2018-06-25
2018-09-25 implementation
State Administration of Markets issued
Ion Chromatography Type Evaluation Outline
Focal Point. National Physical and Chemical Metrology Technical Committee
Main drafting unit. China Institute of Metrology
Participated in drafting unit. Shandong Institute of Metrology
Jilin Institute of Metrology
This specification entrusts the National Physical and Chemical Measurement Technical Committee to explain
The main drafters of this specification.
Shi Naijie (China Institute of Metrology)
Wang Wei (China Institute of Metrology)
Participate in the drafters.
Xu Aihua (Shandong Institute of Metrology)
An Weidong (Jilin Institute of Metrology)
Sun Qianxi (Shandong Institute of Metrology)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Legal management requirements (2)
4.1 Unit of measurement requirements (2)
4.2 signs (2)
5 Measurement requirements (2)
6 General technical requirements (3)
6.1 Appearance of the instrument (3)
6.2 Environmental Adaptability (3)
7 type evaluation item list (3)
8 Provide the number of prototypes and how to use the prototype (4)
8.1 Number of prototypes provided (4)
8.2 How to use the prototype (4)
Test methods and conditions of 9 type evaluation items and data processing and qualification criteria (4)
9.1 Measurement performance test (4)
9.2 General technical requirements test (10)
Judgment of 10 type evaluation results (11)
11 Measuring instruments and equipment used in the test items (11)
12 type evaluation record format (12)
Appendix A Ion Chromatography Type Evaluation Original Record Format (13)
Introduction
This type of evaluation outline is JJF 1015-2014 "General Specification for Type Evaluation of Measuring Instruments" and JJF 1016-
2014 “Guidelines for the Preparation of Types of Measurement Instruments” is prepared for basic specifications.
The technical indicators and test methods of this type evaluation outline refer to JJG823-2014 "Ion Chromatograph",
GB/T 11606-2007 "Analytical Instrument Environmental Test Method" and other technical regulations and standards.
This type of evaluation outline is the first release.
Ion Chromatography Type Evaluation Outline
1 Scope
This type of evaluation outline is applicable to the type evaluation of the classification code 46221500 ion chromatograph, not applicable to
Type evaluation of portable ion chromatography.
2 reference files
JJG823-2014 Ion Chromatograph
GB/T 11606-2007 Analytical instrument environmental test method
For dated references, only dated versions apply to this syllabus; undated quotations
The latest version (including all amendments) applies to this syllabus.
3 Overview
Ion Chromatograph (hereinafter referred to as the instrument) is composed of infusion system, injection system, separation system, detection system and number
According to an analysis instrument composed of a processing system and the like, FIG. 1 is a block diagram showing the composition thereof. Ion chromatograph according to each sample
Separation is achieved by the difference in the distribution of the component ions between the stationary phase and the mobile phase in the column. Bring the sample into the chromatogram by the mobile phase
In the column, different ions are separated and separated with the mobile phase, detected by a detector and recorded by a data processing system.
Figure, qualitative and quantitative analysis based on retention time and response (peak area or peak height) of each component.
The key components and materials that affect the metering performance are shown in Table 1.
Figure 1 Schematic diagram of the composition of the ion chromatograph
Table 1 key components
Serial number name main performance notes
1 infusion pump
Maximum operating pressure
Flow rate range
Flow stability
2 detector
Baseline noise
Baseline drift
|