Calibration Specification for Standard Glass Floats
| Valid |
JJF 1709-2018
|
PDF similar to JJF 1709-2018
Basic data Standard ID | JJF 1709-2018 (JJF1709-2018) | Description (Translated English) | Calibration Specification for Standard Glass Floats | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Word Count Estimation | 12,150 | Date of Issue | 2018-06-25 | Date of Implementation | 2018-09-25 | Regulation (derived from) | State Administration of Markets, Announcement No. 13 of 2018 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1709-2018: Calibration Specification for Standard Glass Floats---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Standard Glass Floats
National Metrology Technical Specification of the People's Republic
Standard Glass Float Calibration Specification
Published on.2018-06-25
2018-09-25 implementation
State Administration of Markets issued
Standard Glass Float Calibration Specification
Focal Point. National Quality Density Measurement Technical Committee
Main drafting unit. China Institute of Metrology
Guangdong Institute of Metrology
Participated in the drafting unit. Xinjiang Uygur Autonomous Region Metrology and Testing Institute
Jiangsu Institute of Metrology
This Code entrusts the National Quality Density Measurement Technical Committee to explain
The main drafters of this specification.
Xu Changhong (China Institute of Metrology)
Yang Jinyong (Guangdong Institute of Metrology)
Participate in the drafters.
Xu Qiusha (Xinjiang Uygur Autonomous Region Metrology and Testing Institute)
Zhou Xu (Jiangsu Institute of Metrology)
Li Zhanhong (China Institute of Metrology)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 terms and units of measurement (1)
3.1 Terminology (1)
3.2 Unit of measurement (1)
4 Overview (1)
5 Measurement characteristics (2)
5.1 Appearance (2)
5.2 Standard temperature (2)
5.3 Density value (2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Standard and other equipment (2)
7 Calibration items and calibration methods (2)
7.1 Calibration Project (2)
7.2 Visual inspection (2)
7.3 Calibration method (2)
7.4 Data Processing (3)
8 Expression of calibration results (3)
9 re-study interval (3)
Appendix A Example of Standard Glass Float Calibration Uncertainty Evaluation (4)
Appendix B Standard Glass Float Calibration Record Reference Format (6)
Appendix C Standard Glass Float Calibration Certificate Inner Page Reference Format (7)
Introduction
JJF 1071-2010 "Rules for the Preparation of National Metrology Calibration Specifications", JJF 1001-2011 "General Terms of Measurement and
Definition", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitutes support for the development of this specification
The basic series of specifications.
The main technical contents of this calibration specification are as follows.
--- Calibration method, comprehensive reference to the experimental methods in ISO and ASTM, combined with the actual measurement experiments,
Set specific calibration parameters. For example, the standard temperature is 23 ° C, the waiting time is 15 min, and the like.
--- The choice of density measurement method, combined with the application status of China, the liquid density measurement uses the glass float method.
In the ISO and ASTM standards, the density bottle method is mainly mentioned, and it is also mentioned that other criteria can be used.
Density measurement method required for accuracy.
--- Analysis of the influence components of the glass float during the calibration process, and gives the calibration uncertainty
Analysis of the example.
This specification is the first release.
Standard Glass Float Calibration Specification
1 Scope
This specification applies to the calibration of standard glass floats.
2 reference files
This specification refers to the following documents.
JJG86-2011 standard glass float meter
JJF 1229-2009 Terms and definitions of mass density measurement
Plastics -- Determination of density of non-foam plastics -- Part 1 . Dipping method, liquid
Relative density bottle method and titration method (Plastics-Methodsfordeterminingthedensityofnon-celular
plastics-Part 1. Immersionmethod, liquidpyknometermethodandtitrationmethod)
Plastics -- Determination of density of non-foam plastics - Part 2
(Plastics-Methodsfordeterminingthedensityofnon-celularplastics-Part 2.Density
Gradientcolumnmethod
ASTMD1505-10 Test Method for Density of Plastics by Density Gradient Method (StandardTestMethod
forDensityofPlasticsbytheDensity-GradientTechnique)
For dated references, only dated versions apply to this specification; undated quotations
The latest version (including all amendments) applies to this specification.
3 terms and units of measure
3.1 Terminology
3.1.1 standard glass float standardglassfloats
Used in density gradient tubes to calibrate special glass beads of liquid density in the tube.
3.1.2 density gradient tube densitygradienttube
It is an instrument that performs density measurement based on changes in liquid density gradient. Forming a liquid column in a density gradient tube, liquid
The density of the liquid in the column is continuously changed from top to bottom, and the density of the liquid in the tube is calibrated with a float.
3.2 Unit of measurement
The density unit is kg/m3 or g/cm3.
4 Overview
Density gradient tube method is widely used in density measurement in petrochemical and pharmaceutical industries. Its measurement principle is that it will be two
a liquid mixture of one or more different densities, forming a liquid column in the density gradient tube, the density of the liquid column being in accordance with the height position
Set linear changes. The standard glass float (hereinafter referred to as the float) and the sample to be tested are suspended in the density gradient tube
degree. The density value of the liquid column in the density gradient tube is calibrated by the density value known from the float, thereby completing the
Measure the density of the sample.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1709-2018_English be delivered?Answer: Upon your order, we will start to translate JJF 1709-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1709-2018_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1709-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|