PDF similar to JJF 1659-2017
Basic data Standard ID | JJF 1659-2017 (JJF1659-2017) | Description (Translated English) | Calibration Specification for PM2.5 Mass Concentration Measurement Instruments | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.020 | Word Count Estimation | 17,161 | Date of Issue | 2017-11-20 | Date of Implementation | 2018-02-20 | Quoted Standard | GB/T 31159-2014; HJ 93-2013; HJ 653-2013 | Regulation (derived from) | AQSIQ Notice 2017 No. 103 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to oscillating balance principle, �� ray principle and the principle of membrane weighing and sample flow rate of 16. 67 L/min, measurement range (10 ~ 1 000) ��g/m ^ 3 PM2.5 mass concentration measuring instrument calibration. The other principle, flow rate and measuring range of the mass concentration meter can be calibrated with reference to this standard. |
JJF 1659-2017: Calibration Specification for PM2.5 Mass Concentration Measurement Instruments---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(PM2.5 mass concentration meter calibration specification)
People's Republic of China National Measurement Specifications
PM2.5 mass concentration meter calibration specification
2017-11-20 Posted
2018-02-20 implementation
General Administration of Quality Supervision, Inspection and Quarantine released
PM2.5 mass concentration meter calibration specification
The focal point. National Environmental Chemistry Metering Technology Committee
The main drafting unit. China Institute of Metrology
Shanghai Institute of Measurement and Testing Technology
Chinese Academy of Environmental Sciences
Participate in the drafting unit. Shandong Provincial Environmental Monitoring Center Station
Qingdao Institute of Measurement Technology
Qingdao Laoshan Institute of Applied Technology
Guangdong Institute of Metrology
This specification entrusts the National Environmental Chemistry Metrology Technical Committee responsible for the interpretation
The main drafters of this specification.
Zhang Wenge (China Institute of Metrology)
Ding Zhenmin (Shanghai Institute of Measurement and Testing Technology)
Yang Wen (China Academy of Environmental Sciences)
Participate in the drafters.
Xu Xiao (China Institute of Metrology)
Liu Wei (Shandong Provincial Environmental Monitoring Center Station)
Xia Chun (Qingdao Institute of Metrology Technology)
Liang Yong (Qingdao Laoshan Institute of Applied Technology)
Chen Ling (Guangdong Institute of Metrology)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 References (1)
3 Terms and measurement units (1)
4 Overview (1)
5 Metrology (2)
5.1 flow indication error (2)
5.2 average flow deviation (2)
5.3 Traffic Repeatability (2)
5.4 Flow Stability (2)
5.5 timing error indication (2)
5.6 Temperature indication error (2)
5.7 atmospheric pressure indication error (2)
5.8 Zero drift (2)
5.9 concentration indication error (2)
6 Calibration conditions (2)
6.1 Calibration of environmental conditions (2)
6.2 Instrument Requirements (2)
6.3 Measurement standards and other equipment (2)
7 Calibration Items and Calibration Methods (3)
7.1 Preparation before calibration (3)
7.2 flow indication error (3)
7.3 Average flow deviation (3)
7.4 Traffic Repeatability (3)
7.5 Flow Stability (4)
7.6 timing indication error (4)
7.7 Temperature indication error (4)
7.8 Atmospheric pressure indication error (5)
7.9 Zero drift (5)
7.10 concentration indication error (5)
8 Calibration Results (6)
9 time interval of correction (6)
Appendix A shows the uncertainty of the indication of concentration error (7)
Appendix B PM2.5 Mass Tester Calibration Recording Formats (Reference) (9)
Appendix C PM2.5 Mass Conductivity Meter Calibration Certificate (Inside Page) Format (Reference) (11)
Appendix D PM2.5 Aerosol Blending Device Schematic (12)
Introduction
The nomenclature and technical specifications refer to GB/T 31159-2014 "Aerosol Observation Terms"
HJ93-2013 "Ambient Air Particulate Matter (PM10 and PM2.5) Sampler Technical Requirements and Test Methods",
HJ653-2013 "Environmental Air Particles (PM10 and PM2.5) Continuous Automatic Monitoring System Technical Requirements and Testing
Method "and other technical regulations, standards.
This specification is first released.
PM2.5 mass concentration meter calibration specification
1 Scope
This specification is based on the principle of oscillation balance, b-ray principle and the principle of membrane filtration and sampling flow rate of
16.67 L/min, calibration range of PM2.5 measuring instrument (10 ~ 1000) μg/m3. other
Principle, flow and measuring range of mass concentration measuring instrument can be calibrated with reference to this specification.
2 reference documents
This specification cites the following documents.
Atmospheric aerosol observation terminology GB/T 31159-2014
HJ93-2013 Ambient Air Particulate Matter (PM10 and PM2.5) Sampler Technical Requirements and Test Methods
HJ653-2013 Environmental Air Particles (PM10 and PM2.5) Continuous Automatic Monitoring System Technical Requirements and Inspection
Test method
For dated references, only the dated version applies to this specification; for undated references
The latest version of this specification applies to this specification.
3 Terms and measurement units
3.1 Aerodynamic diameter aerodynamicdiameter
The particles have the same movement speed, the density of 1g/cm3 spherical particles diameter.
3.2 Fine Particle (PM2.5)
Aerosol particles with aerodynamic diameters less than or equal to 2.5 μm.
3.3 cutter particleseparatedevice
Refers to the separation of particles with different particle size device.
3.4 Working point flowrateraterate
Under working conditions, the sample flow remains constant and the flow of cutting characteristics is guaranteed.
4 Overview
PM2.5 mass concentration meter (hereinafter referred to as instrument) is used to measure the ambient air aerodynamic diameter is not
An instrument with a mass concentration of particles larger than 2.5 μm. According to the different principle of measuring instruments, divided into filter weighing method,
Oscillating balance method, β-ray absorption method. Instrument generally by the sample acquisition unit (including the sampling port, PM2.5 cutter and
Sampling tube, etc.), sample measurement unit, data processing unit and display unit. Its working principle is. Instruments to constant
Constant flow extraction of ambient air samples, the sample collection unit will be cut and separated particles sent to the sample measurement sheet
Yuan, the sample measurement unit for PM2.5 particulate matter measurement, the data processing unit will measure the results of the analyzer
Count, the final output by the display unit measurement results. Instrument structure diagram shown in Figure 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1659-2017_English be delivered?Answer: Upon your order, we will start to translate JJF 1659-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1659-2017_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1659-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|