US$649.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1631-2017: Calibration Specification for Continuous Thermocouples Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1631-2017 | English | 649 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification for Continuous Thermocouples
| Valid |
JJF 1631-2017
|
PDF similar to JJF 1631-2017
Basic data Standard ID | JJF 1631-2017 (JJF1631-2017) | Description (Translated English) | Calibration Specification for Continuous Thermocouples | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A54 | Classification of International Standard | 17.200 | Word Count Estimation | 28,263 | Date of Issue | 2017-09-26 | Date of Implementation | 2017-12-26 | Quoted Standard | JJG 160-2007 | Regulation (derived from) | General Administration of State Quality Inspection Announcement 2017 No. 78 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard is applicable to the calibration of continuous thermocouples using the data in Appendix A as indexing tables in the range of 80��C to 80��C. The calibration of continuous thermocouples in other temperature ranges can also refer to this standard. |
JJF 1631-2017: Calibration Specification for Continuous Thermocouples---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Continuous thermocouple calibration specification)
People's Republic of China National Measurement Specifications
Continuous thermocouple calibration specification
Calibration Specification for Contoured Thermocouples
2017-09-26 Posted
2017-12-26 Implementation
General Administration of Quality Supervision, Inspection and Quarantine released
Continuous thermocouple calibration specification
The focal point. National Temperature Measurement Technical Committee
The main drafting unit. Beijing Institute of Metrology
China Institute of Metrology
Chongqing Materials Research Institute Co., Ltd.
Tianjin Institute of Measurement Supervision and Inspection
Participate in the drafting unit. Shandong Institute of Metrology
Zhejiang Ritter Electrical Co., Ltd
This specification entrusts the national temperature measurement technical committee to be responsible for explaining
The main drafters of this specification.
Zhang Ke (Beijing Institute of Metrology and Measurement)
Chen Wei Xin (China Institute of Metrology)
Chen Lixin (Chongqing Institute of Materials Co., Ltd.)
Tian Yun (Tianjin Institute of Metrology and Supervision)
Participate in the drafters.
Wu Jian (Beijing Institute of Metrology and Measurement)
Li Ying (Shandong Institute of Metrology)
Wu Gallen (Zhejiang Rant Electrical Co., Ltd.)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 References (1)
3 Terms (1)
3.1 Continuous Thermocouple (1)
3.2 Thermal materials (1)
3.3 indication deviation (1)
3.4 Uniformity (1)
4 Overview (1)
5 Metrology (2)
5.1 indication deviation (2)
5.2 Uniformity (2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Measuring standard equipment and ancillary equipment (2)
7 Calibration Items and Calibration Methods (3)
7.1 Calibration Items (3)
7.2 Calibration Methods (3)
7.3 Calibration Results Processing (6)
8 expression of calibration results (7)
Appendix A Continuous thermocouple indexing table (9)
Appendix B Thermocouple test furnace calibration deviation indication method (13)
Appendix C Continuous Thermocouple Calibration Original Record (16)
Appendix D Calibration Certificate Internal Page Format (19)
Appendix E continuous thermocouple temperature indication deviation calibration uncertainty evaluation example (20)
Introduction
This specification is based on JJF 1071-2010 "National Metrology Calibration Rules Preparation Rules" drafting, in which the measurement results are not
The determination of the degree of certainty is based on JJF 1059.1-2012 "Evaluation and Expression of Measurement Uncertainty".
This specification is first released.
Continuous thermocouple calibration specification
1 Scope
This standard applies to continuous thermocouple data in Appendix A indexing table, in the range of 80 ℃ ~ 800 ℃
calibration.
Continuous thermocouple calibration in other temperature ranges can also refer to this specification.
2 reference documents
This specification cites the following documents.
JJG160-2007 standard platinum resistance thermometer
For dated references, only the dated version applies to this specification; for undated references
The latest version (including all amendments) applies to this specification.
3 Terms
3.1 Continuous thermocouple continuousthermocouples
An able to detect the highest temperature along the line, for temperature alarm over the armored thermocouple.
3.2 Thermal materials thermo-sensitivematerial
Filled with continuous thermocouple between two hot electrodes and between the hot electrode and the metal sleeve with a negative resistance - temperature
Coefficient properties of powdered inorganic material.
3.3 Indication deviation indicationdeviation
In the reference end is 0 ℃, the continuous thermocouple thermocouple output on its index table deviation from the temperature converted into
Degree value.
3.4 uniformity uniformityofvalue
Among the series of indication deviations obtained at several temperature locations along a length distribution of a continuous thermocouple at a specific temperature, most
The difference between the maximum value and the minimum value.
4 Overview
Continuous thermocouple also known as heat-seeking thermocouple, is a thermocouple without fixed hot junction, through the armor process will be
Thermal material (filler material) and K-type thermocouple together, in a certain temperature range, can be continuously generated
With the contact with the hottest temperature in the corresponding thermoelectric power signal, you can get the highest temperature along the line. In a row
Thermocouples are provided with terminals on either or both sides of the thermocouple to measure the thermoelectric power potential from either side or from one side respectively. continuous
Thermocouple temperature measurement range is generally 80 ℃ ~ 800 ℃, the length of 2m to 40m or so, covering a wide range of savings
A large number of temperature sensors and electrical test equipment. Widely used in chemical, mechanical, energy, shipping, aviation, telecommunications, electricity
Force, storage and other large, large-scale, large space places and dangerous areas of fever, overheating monitoring, pre
Police and so on.
Continuous thermocouple structure shown in Figure 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1631-2017_English be delivered?Answer: Upon your order, we will start to translate JJF 1631-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1631-2017_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1631-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|