US$1019.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1585-2016: Calibration Specification for Continuous Emission Monitoring Systems of Flue Gas Emitted from Stationary Source Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1585-2016 | English | 1019 |
Add to Cart
|
6 days [Need to translate]
|
Calibration Specification for Continuous Emission Monitoring Systems of Flue Gas Emitted from Stationary Source
| Valid |
JJF 1585-2016
|
PDF similar to JJF 1585-2016
Basic data Standard ID | JJF 1585-2016 (JJF1585-2016) | Description (Translated English) | Calibration Specification for Continuous Emission Monitoring Systems of Flue Gas Emitted from Stationary Source | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Word Count Estimation | 44,472 | Date of Issue | 2016-11-25 | Date of Implementation | 2017-02-25 | Regulation (derived from) | State Administration of Quality Supervision, Inspection and Quarantine Notice No.116 of 2016 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine |
JJF 1585-2016: Calibration Specification for Continuous Emission Monitoring Systems of Flue Gas Emitted from Stationary Source ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Continuous Emission Monitoring Systems of Flue Gas Emitted from Stationary Source
National Metrological Technical Code of the People's Republic of China
Fixed pollution source smoke emission continuous monitoring system
Calibration specification
2016-11-25 release
2017-02-25 Implementation
State Administration of Quality Supervision, Inspection and Quarantine issued
Fixed source of smoke
Continuous monitoring system calibration specification
CalibrationSpecification forContinuous
Source
Responsible unit. National Environmental Chemical Metrology Technical Committee
The main drafting unit. State Grid Henan Electric Power Company Electric Power Research Institute
Shanghai Institute of Metrology and Testing Technology
Participated in the drafting unit. China Institute of Metrology
Shanghai Environmental Monitoring Center
This specification entrusts the National Environmental Chemistry Metrology Technical Committee to explain
The main drafters of this specification.
Guo Yang (State Grid Henan Electric Power Company Electric Power Research Institute)
Chen Song (State Grid Henan Electric Power Company Electric Power Research Institute)
Ding Zhenmin (Shanghai Institute of Metrology and Testing Technology)
Participate in the drafters.
Wu Wenlong (State Grid Henan Electric Power Company Electric Power Research Institute)
Zhou Zeyi (China Institute of Metrology)
Chen Yonghua (China Institute of Metrology)
Sun Yi (Shanghai Environmental Monitoring Center)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metering characteristics (1)
5 Calibration conditions (3)
5.1 Environmental conditions (3)
5.2 Calibration standard and corresponding equipment (3)
6 Calibration items and calibration methods (4)
6.1 Appearance (4)
6.2 Check the system sampling installation location and protective measures (4)
6.3 Calibration of measurement characteristics in system non-operating conditions (4)
6.4 Calibration of measurement characteristics in system operating conditions (8)
7 Calibration results (11)
8 Recurrence time interval (12)
Appendix A Calibration Certificate Inside Page Format (13)
Appendix B Calibration Record Format (16)
Appendix C Humidity measurement (23)
Appendix D Particulate matter, flow rate measurement method (24)
Appendix E Uncertainty of measurement uncertainty for indication error (25)
Introduction
This specification is a metrological calibration standard for continuous monitoring of flue gas emissions from fixed sources. This specification
The preparation of the JJF 1071-2010 "national measurement calibration norms to write rules", JJF 1001-2011 "General
Measurement Terms and Definitions "and JJF 1059.1-2012" Measurement Uncertainty Assessment and Representation "
according to. The main reference standard of this specification is HJ/T 75-2007 "fixed pollution source flue gas emissions continuous monitoring technical regulations
Technical Requirements and Testing of Continuous Monitoring System for Flue Gas Emissions from Fixed Pollution Source of "HJ/T 76-2007"
Method (trial) ".
This specification is the first release.
Fixed pollution source smoke emission continuous monitoring system
Calibration specification
1 Scope
This specification applies to non-working conditions and conditions of work under the fixed source of smoke emissions continuous monitoring system measurement special
Sexual calibration.
2 reference file
This specification refers to the following documents.
Determination of particulate matter and sampling method of gaseous pollutants in exhaust gas of fixed pollution sources GB/T 16157
For dated references, only the dated edition applies to this specification; references that are not dated
, The latest version (including all modifications) applies to this specification.
3 Overview
Fixed pollution sources Flue gas discharge continuous monitoring system (hereinafter referred to as the system) by the particulate matter monitoring subsystem,
Dye monitoring subsystem, smoke emission parameter measurement subsystem, data acquisition, transmission and processing subsystem and so on. through
Oversampling and non-sampling methods, determination of particulate matter concentration in flue gas, gaseous pollutant concentration, flue gas temperature, flue gas pressure
Force, flue gas flow rate, flue gas moisture content (or input flue gas content), flue gas oxygen (or carbon dioxide content)
And other parameters; at the same time calculate the concentration of pollutants in flue gas and emissions, display and print a variety of parameters, charts and through the data
Teletext transmission system to a continuous pollution source smoke emission continuous monitoring system.
4 measurement characteristics
Fixed pollution sources Flue gas emissions Continuous monitoring system Metrological characteristics are divided into non-working conditions for the main metrological characteristics (see
Table 1) and the main measurement characteristics under the condition of the condition (see Table 2).
Table 1 Main measurement characteristics of the calibrated system in non-operating conditions
Project testing project technical requirements
particulates
Zero drift ≤1%
Indication error ± 2.0%
Repeatability ≤1.0%
Sulfur dioxide
Response time ≤90s
Zero drift ≤2%
Range drift ≤3%
Indication error ± 5%
Repeatability ≤2%
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1585-2016_English be delivered?Answer: Upon your order, we will start to translate JJF 1585-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1585-2016_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1585-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|