JJF 1542-2015: Calibration Specification for SpO2 Simulator
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1542-2015English329 Add to Cart 3 days [Need to translate] Calibration Specification for SpO2 Simulator Valid JJF 1542-2015

PDF similar to JJF 1542-2015


Standard similar to JJF 1542-2015

JJF 1835   JJF 1800   JJF 1071   JJF 1261.6   JJF 1261.5   JJF 1541   

Basic data

Standard ID JJF 1542-2015 (JJF1542-2015)
Description (Translated English) Calibration Specification for SpO2 Simulator
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A50
Classification of International Standard 17.020
Word Count Estimation 14,190
Date of Issue 2015-08-24
Date of Implementation 2015-11-24
Quoted Standard JJF 1059.1-2012
Regulation (derived from) AQSIQ Announcement 2015 No.106
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This Standard applies to the photoelectric pulse oximetry simulator calibration.

JJF 1542-2015: Calibration Specification for SpO2 Simulator

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Oxygen saturation simulation Calibration Specification) People's Republic of China National Metrology Technical Specifications Oxygen saturation simulation Calibration Specification Issued on. 2015-08-24 2015-11-24 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Oxygen saturation simulation Calibration Specification SpO2Simulator Focal point. the National Technical Committee on Medical Measurement The main drafting units. China Institute of Metrology Participated in the drafting unit. Beijing Medical Technology Co., Ltd. is satisfied that male People's Liberation Army General Logistics Department of the Ministry of Health and Drug Control Chinese Academy of Sciences Institute of Optical Technology Fluke test equipment (Shanghai) Co., Ltd. This specification entrusted to the National Technical Committee is responsible for interpreting medical measurement The main drafters of this specification. Pu Zhang (China Institute of Metrology) Sun Jie (China Institute of Metrology) Drafters participate. Shaw Magpie (Beijing Medical Technology Co., Ltd. is satisfied male) Hongbao Yu (China Institute of Metrology) Jia Jiange (People's Liberation Army General Logistics Department of the Ministry of Health and Drug Control) Shi Guohua (Institute of Optoelectronic Technology Institute) Cui smile (Fluke test equipment (Shanghai) Co., Ltd.)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 oximetry (value) (1) 3.2 R value (1) 3.3 R value of the curve (1) 3.4 pulse rate (value) (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 oximetry value (1) 5.2 pulse frequency (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 standards and other measuring equipment (2) 7 Calibration methods and calibration items (2) 7.1 appearance and function check (2) 7.2 oxygen saturation values (2) 7.3 pulse frequency indication error (3) 8 calibration results expression (3) 9 Recalibration interval (4) Appendix A simulation of oxygen saturation Calibration original records (recommended) formatting styles (5) Appendix B calibration certificate within the page (recommended) formatting styles (6) Appendix C oxygen saturation calibration value of Uncertainty Evaluation Example (8)

Introduction

Preparation of this specification to JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "General measurement terms and definitions", JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" basis and in accordance with. The specification for the first time to develop. Oxygen saturation simulation Calibration Specification

1 Scope

This standard applies to the photoelectric pulse oximetry simulator calibration. 2. References This specification references the following documents. JJF 1059.1-2012 Evaluation and Expression of Uncertainty in Measurement For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement

3.1 oximetry (value) oxygensaturation (value) Oxygen saturation (SpO2) in the blood is bonded to oxygen oxyhemoglobin (HbO2) of the total capacity available The combined percentage of hemoglobin (Hb) capacity. 3.2 R value Rvalue Red and infrared light absorbed by human tissue ratio after. Pulse oximeter obtained based on the ratio calculation Body arterial oxygen saturation values. 3.3 R value curve Rvaluecurves Correspondence between the R value and the oxygen saturation values is called the R value of the curve, NECOLLOR, BCI and MASI- MO is one of three most common R-value curve. 3.4 pulse rate (value) pulserate (value) The number of beats per minute arteries. Unit. beats/min.

4 Overview

Oximetry simulator (hereinafter referred to as "simulator") simulate the human values of oxygen saturation and pulse rate values, And it can be used to detect the pulse oximeter and multi-parameter monitor blood oxygen saturation in the module. Analog simulation of the optical instrument Composition means and the host of two parts, optical simulation refers to the lower surface is equipped with two optical sensors are used to detect red and infrared Optical signal; the upper surface is provided with a light emitter. Simulator work, refers to optical analog light sensor receives light signals Forming two pulse after pulse as a trigger signal to the host, the host according to the parameters menu settings to control light emission Light signals emitted by the optical signal acquisition and prior to the trigger signal synchronization, simulated light transmitted through a human finger After the light attenuation. Controlled optical signal simulator output pulse oximeter was measured after the pulse oximetry And of the corresponding instrument available oxygen saturation and pulse frequency values.

5 Metrological characteristics

5.1 oxygen saturation values

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1542-2015_English be delivered?

Answer: Upon your order, we will start to translate JJF 1542-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1542-2015_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1542-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.