US$419.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1531-2015: Calibration specification for fourier transform mass spectrometers Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1531-2015 | English | 419 |
Add to Cart
|
4 days [Need to translate]
|
Calibration specification for fourier transform mass spectrometers
| Valid |
JJF 1531-2015
|
PDF similar to JJF 1531-2015
Basic data Standard ID | JJF 1531-2015 (JJF1531-2015) | Description (Translated English) | Calibration specification for fourier transform mass spectrometers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.02 | Word Count Estimation | 18,175 | Date of Issue | 2015-06-15 | Date of Implementation | 2015-09-15 | Quoted Standard | GB/T 6041-2002 | Regulation (derived from) | AQSIQ Announcement 2015 No.72 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to the Fourier transform mass spectrometer calibration. |
JJF 1531-2015: Calibration specification for fourier transform mass spectrometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Fourier transform mass spectrometer calibration specification)
People's Republic of China National Metrology Technical Specifications
Fourier transform mass spectrometer calibration specification
Issued on. 2015-06-15
2015-09-15 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Fourier transform mass spectrometer calibration specification
TransformMassSp
ectrometers
NFP. National Technical Committee biometric
Main drafting unit. Institute of Materia Medica Chinese Academy of Medical Sciences
Participated in the drafting unit. China Institute of Metrology
This specification entrusted to the National Technical Committee is responsible for interpreting biometric
The main drafters of this specification.
ZHANG Jin-lan (Institute of Materia Medica Chinese Academy of Medical Sciences)
Wucai Sheng (Institute of Materia Medica Chinese Academy of Medical Sciences)
Drafters participate.
Wu Liqing (China Institute of Metrology)
Qu Feng (Institute of Materia Medica Chinese Academy of Medical Sciences)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
3.1 The term (1)
3.2 units of measurement (1)
4 Overview (1)
4.1 Basic Principle (1)
4.2-instrument (2)
5 Metrological characteristics (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 Standard materials and reagents (2)
7 calibration items and calibration methods (3)
7.1 Indication error (3)
SNR 7.2 (3)
7.3 resolving power (3)
7.4 Repeatability (4)
Drift 7.5 (4)
8 calibration results expression (4)
9 Recalibration interval (5)
Appendix A preparation and use of reference material solution (6)
Appendix B Calibration record format (7)
Appendix C calibration certificate page format (10)
Uncertainty Evaluation of Indication Error Examples Appendix D (11)
Introduction
This specification based on the national measurement specifications JJF 1071-2010 "national measurement standards to prepare rules"
JJF 1001-2011 "common measurement terms and definitions" JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement"
prepared by.
Development of this specification primarily with reference to GB/T 6041-2002 "General mass spectrometry method" and other documents.
This specification is the first release.
Fourier transform mass spectrometer calibration specification
1 Scope
This standard applies to the Fourier transform mass spectrometer calibration.
2. References
This specification references the following documents.
GB/T 6041-2002 General Mass Spectrometry
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
3.1 Terms
3.1.1 Sensitivity sensitivity [GB/T 6041-20022.2]
Under specified conditions, the response to the value of a mass peak, the instrument unit generated by the sample.
3.1.2 The ability to distinguish resolution
In a given sample conditions, instrument two adjacent mass peaks discriminatory power. Two adjacent high-mass spectrometry
When the peak, the peak is not more than 10% of the peak height, it is defined as can be distinguished.
Note. The ability to distinguish two peaks of representation when R peak at 10% peak height, the quality of the two peaks represented by the average value of quality
The ratio of the amount of the difference. When describing the use of mass spectral peak mass to charge ratio, listed in the corresponding resolution of the data is appropriate, because
Different instruments, while its resolving power varies with different mass to charge ratio.
3.1.3 SNR signaltonoiseratio [GB/T 6041-20022.9]
In mass spectrometry, the signal strength and noise intensity ratio.
3.2 units of measurement
Atomic mass units (u) atomicmassunit [JJF 1164-20063.6]
4 Overview
4.1 Fundamentals
Fourier transform mass spectrometer according to different mass analyzers are divided into two categories. Fourier transform ion cyclotron resonance mass spectrometry
Fourier transform instrument and Orbitrap mass spectrometer.
Fourier transform ion cyclotron resonance mass spectrometer is a core component in a high magnetic field of the ion cyclotron resonance trap
(ICRiontrap) --- analysis room, which can capture and store ions in a high magnetic field. The basic principle is to leave
Ion source produces an ion beam is introduced ICR ion trap under the action of magnetic force, all the ions are beginning along well
Center to do a small radius of cyclotron motion. If the magnetic field strength B is fixed, and only the cyclotron frequency of the ion mass to charge ratio have
And independent of the customs and ion kinetic energy. When the frequency of the high frequency signal is applied and the frequency of a mass to charge ratio of ions in a cyclotron motion
When delivered, the ions will absorb the energy of a high-frequency electrical signals, the cyclotron radius of motion increases. When stopping the high-frequency excitation
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1531-2015_English be delivered?Answer: Upon your order, we will start to translate JJF 1531-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1531-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1531-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|