US$1659.00 · In stock Delivery: <= 10 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1522-2015: Program of Pattern Evaluation of Hot Water Meters Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1522-2015 | English | 1659 |
Add to Cart
|
10 days [Need to translate]
|
Program of Pattern Evaluation of Hot Water Meters
| Valid |
JJF 1522-2015
|
PDF similar to JJF 1522-2015
Standard similar to JJF 1522-2015 GB/T 20730.2 GB/T 19146 CJ 128
Basic data Standard ID | JJF 1522-2015 (JJF1522-2015) | Description (Translated English) | Program of Pattern Evaluation of Hot Water Meters | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | N11 | Word Count Estimation | 72,742 | Date of Issue | 2015-04-10 | Date of Implementation | 2015-10-10 | Older Standard (superseded by this standard) | JJG 686-2006 (Partial) | Quoted Standard | JJG 162-2009; JJF 1001; JJF 1004; GB/T 778.1-2007; GB/T 778.3-2007; GB/T 2421; GB/T 2422; GB/T 2423.1; GB/T 2423.2; GB/T 2423.4; GB/T 2423.43; GB/T 2423.56; GB/T 2424.1; GB/T 17626.2; GB/T 17626.3; GB/T 17626.4; GB/T 17626.5; GB/T 17626.11; OIML R49-1-2013(E); OIML R49-2-2013(E) | Regulation (derived from) | State Quality Inspection Administration Announcement 2015 No. 47 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to classification and coding of 12, 201, 000 of hot water (hereinafter referred to as the water table) of pattern evaluation, the scope of application of the hot water meter nominal diameter of not more than 300mm, the maximum temperature does not exceed 130 ��. |
JJF 1522-2015: Program of Pattern Evaluation of Hot Water Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Hot water type evaluation outline)
People's Republic of China National Metrology Technical Specifications
Hot water type evaluation outline
Issued on. 2015-04-10
2015-10-10 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Hot water type evaluation outline
Instead of JJG686-2006
Type Evaluation Outline section
Focal point. the National Technical Committee on Metering flow capacity
Main drafting unit. Zhejiang Institute of Metrology
Beijing Institute of Metrology detection
Shandong Province Institute of Metrology
Participated in the drafting unit. Ningbo Water Meter Co., Ltd
Xintian Technology Co., Ltd.
Ningbo Water Meter Co., Ltd Wenling Ridge
This specification flow capacity commissioned the National Technical Committee responsible for the interpretation of measurement
The main drafters of this specification.
Zhan Zhijie (Zhejiang Institute of Metrology)
Zhang Liqian (Beijing Institute of Metrology detection)
Ji Jianying (Shandong Province Institute of Metrology)
Drafters participate.
Lu Jiaying (Zhejiang Institute of Metrology)
Zhao Shao full (Ningbo Water Meter Co., Ltd.)
Fees war wave (Xintian Technology Co., Ltd.)
Fanyong Lian (Wenling Yong Ling meter Limited)
table of Contents
Introduction (Ⅲ)
1 Scope (1)
2. References (1)
3 The term (2)
3.1 Time Traffic Act (2)
3.2 meter temperature class (2)
3.3 auxiliary devices (2)
Replaceable 3.4 meter metering elements (2)
4 Overview (2)
4.1 principles and structures (2)
4.2 Classification (3)
5 legal management requirements (4)
5.1 units of measurement (4)
Flag 5.2 (4)
5.3 external structural design requirements (4)
6 measurement requirements (4)
6.1 Metrological characteristics (4)
6.2 accuracy class and the maximum permissible error (5)
7 General Requirements (5)
7.1 Materials and Structures (5)
7.2 adjustments and amendments (6)
7.3 Installation conditions (6)
7.4 Rated operating conditions (7)
7.5 mark and nameplate (7)
7.6 indicating means (8)
7.7 guard (10)
7.8 Pressure loss (10)
7.9 Compressive strength (11)
7.10 Durability (11)
7.11 with an electronic device function hot table (11)
7.12 Static magnetic field (13)
7.13 environmental adaptability (13)
8 pattern evaluation item list (18)
8.1 All types of evaluation items (18) to be carried out water table
8.2 performance test project with an electronic device water table (18)
9 provides prototype quantities and use prototypes (19)
9.1 provide experimental prototype number (19)
Use 9.2 Prototype (20)
9.3 Prototype related documents (20)
Test methods and conditions as well as data processing and compliance criteria 10 pilot projects (21)
10.1 General Test Conditions (21)
10.2 Legal Metrology inspection (22)
10.3 Static pressure test (22)
10.4 intrinsic error test (22)
10.5 no-flow test (25)
10.6 Effect of temperature test (25)
10.7 overload test the water temperature (26)
10.8 Effect of hydrostatic test (26)
10.9 Reverse flow test (26)
10.10 Pressure loss test (27)
10.11 Flow disturbance tests (29)
10.12 static magnetic field trials (30)
10.13 Durability test (30)
10.14 function tests (34)
10.15 climate test - dry heat (non-condensing) (34)
10.16 Climate Test - Low Temperature (35)
10.17 Climate Tests - Damp heat (condensation) (36)
10.18 power variation test - voltage variation (36)
10.19 power variation test - battery power (38)
10.20 Mechanical environmental tests - Vibration (random) (38)
10.21 Mechanical environmental tests - mechanical shock (39)
10.22 Electromagnetic Environmental testing - momentary power interruption (40)
10.23 Electromagnetic Environmental testing - burst (40)
10.24 Electromagnetic Environmental testing - Surge Immunity (41)
10.25 Electromagnetic Environmental Testing - Electrostatic discharge (42)
10.26 Electromagnetic Environmental testing - electromagnetic susceptibility (43)
11 test items of measuring instruments used in the table (44)
Appendix A pattern evaluation record format (46)
Appendix B flows interfere with the installation test requirements (65)
Introduction
This specification is based on GB/T 778.1 ~ 3-2007 "closed conduits Measurement of water flow cold potable water
And hot water ", the International Organization of Legal Metrology (OIML) International Recommendation OIMLR49-1.2013 (E)" measure
The amount of potable water meter cold and hot water - Part 1. metrological and technical requirements "and OIMLR49-2.2013 (E)
"Measurement of potable cold water and hot water - Part 2. Test methods" as the basis for the preparation, combined with our hot water
Table manufacturing industry status and use of the "water table Pattern Evaluation Outline" JJG686-2006 be revised Appendix A
of. The main technical indicators and national equivalents.
This specification Press JJF 1016-2014 "appliance type evaluation outline guidelines for the preparation of measurement" Writing.
This specification compared with the type of evaluation outline JJG686-2006 Appendix A, the main technical changes are as follows.
--- In outline the scope of the re-provision. In addition to mechanical water table, the increase based on electromagnetic or electronic
Working principle water table; water table by the maximum operating temperature of 180 ℃ to 130 ℃, and is represented by the temperature class;
--- Press JJF 1016, experimental prototype to increase the type approval mark and number of requirements in terms of signs;
Flow characteristics --- water table by Q1, Q2, Q3, Q4 OK, replace the original characteristics of the traffic sign; all with hot
Expression meter performance and error test related parameters according to the flow of new features;
--- Water table by Q3 (in m3/h units) and ratios flag Q3/Q1, Q2/Q1, and the provisions of the Department of
The number of columns, an alternative expression of the original code and measurement meter level A, B, C, D of;
--- Type of pilot projects to increase the influence of test temperature, water temperature overload test, reverse flow experiment, the flow interference test
Inspection, static magnetic field test; with electronic devices for water table increases the functionality test, climate test, power supply variation test
And electromagnetic environmental testing; measuring unit for exchangeable water table, increasing the metering unit replacement pilot projects;
--- For Q3 > 16m3/h water table, reducing the durability test time;
--- Increased Chapter 10, "Test methods and conditions as well as data processing and acceptance criteria of the pilot project," the
content;
--- Increased determination method selection series, complementing the various projects to test prototypes quantity requirements;
--- Added Appendix A "record format type evaluation" of the content;
The previous versions of this specification published case.
--- JJG686-2006 "water table" in Appendix A.
Hot water type evaluation outline
1 Scope
This type of evaluation framework applicable to classification and coding of hot water 12201000 (hereinafter referred to as the water table) type
Type evaluation, the scope of the water table a nominal diameter of not more than 300mm, the maximum temperature does not exceed 130 ℃.
2. References
JJG162-2009 cold water
JJF 1001 common measurement terms and definitions
JJF 1004 flow measurement terminology and definitions
Measurement of water flow in closed conduits 778.1-2007 GB/T cold potable water and hot water first
Part 1. Specification (idtISO 4064-1.2005)
Measurement of water flow in closed conduits 778.3-2007 GB/T cold potable water and hot water first
Part 3. Test methods and equipment (idtISO 4064-3.2005)
GB/T 2421 Environmental testing for electric and electronic products - Part 1. General
GB/T 2422 electric and electronic products environmental testing terminology
GB/T 2423.1 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold
GB/T 2423.2 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat
GB/T 2423.4 Environmental testing for electric and electronic products Part 2. Test methods - Test Db alternating hot and humid
(12h 12h cycle)
GB/T 2423.43 Environmental testing for electric and electronic products Part 2. Test methods for vibration, shock and class
Like kinetic installation of the test sample
GB/T 2423.56 Environmental testing for electric and electronic products Part 2. Test methods - Test Fh. Broadband with
Machine vibration (digital control) and guidance
GB/T 2424.1 electric and electronic products environmental testing high temperature and low temperature tests
GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test
GB/T 17626.4 Electromagnetic compatibility Testing and measurement techniques - Electrical fast transient burst immunity test
GB/T 17626.5 electromagnetic compatibility test and measurement technology surge (impact) immunity test
GB/T 17626.11 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations
Immunity Test
OIMLR49-1.2013 (E) measure potable cold and hot water meter Part 1. Measurement and Technology
Surgery requirements (Watermetersintendedforthemeteringofcoldpotablewaterandhotwater-
Part 1. Metrologicalandtechnicalrequirements)
OIMLR49-2.2013 (E) measure potable cold and hot water water - Part 2. Test methods
(Watermetersintendedforthemeteringofcoldpotablewaterandhotwater-Part 2.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1522-2015_English be delivered?Answer: Upon your order, we will start to translate JJF 1522-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 6 ~ 10 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1522-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1522-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|