JJF 1497-2014: Calibration Specification for Polarimeters
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1497-2014English349 Add to Cart 3 days [Need to translate] Calibration Specification for Polarimeters Valid JJF 1497-2014

PDF similar to JJF 1497-2014


Standard similar to JJF 1497-2014

GB/T 43191   GB/T 15284   JJG 2059   

Basic data

Standard ID JJF 1497-2014 (JJF1497-2014)
Description (Translated English) Calibration Specification for Polarimeters
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard N21
Word Count Estimation 15,195
Date of Issue 11/17/2014
Date of Implementation 2/17/2015
Quoted Standard GB/T 26827-2011
Regulation (derived from) The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 No. 125
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This Standard applies to the use of polarized light measuring various types of polarizing material phase delay the calibration.

JJF 1497-2014: Calibration Specification for Polarimeters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Polarimeters People's Republic of China National Metrology Technical Specifications Polarizing calibration specification Issued on. 2014-11-17 2015-02-17 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Polarizing calibration specification Focal point. the National Technical Committee on Optical metrology The main drafting units. China Institute of Metrology Shanghai Measurement and Testing Technology Research Institute Participated in the drafting. national security glass and quartz glass Quality Supervision and Inspection Center This specification committee commissioned by the National Optical measurement technology is responsible for interpreting The main drafters of this specification. Victor Fung Jin (China Institute of Metrology) Zhengchun Di (China Institute of Metrology) Xia Ming (Shanghai Institute of Measurement and Testing) Drafters participate. Wang Jing Jing (national security glass and quartz glass Quality Supervision and Inspection Center)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Terms (1) 3.1 phase delay (1) 3.2 polariscope (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 light spectrum half width (1) 5.2 the zero phase delay (2) 5.3 phase delay Repeatability (2) 5.4 phase delay indication error (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 standards and other measuring equipment (2) 7 calibration items and calibration methods (2) 7.1 light spectrum half width (2) 7.2 Instrument zero adjustment (3) 7.3 phase delay zero point drift (3) 7.4 phase delay indication error and repeatability (3) 8 calibration results expression (3) 9 Recalibration interval (4) Appendix A polarizing recommended calibration original record format (5) Appendix B Calibration Certificate-page format recommended (6) Evaluation of Uncertainty Appendix C Calibration Indication Error polarization measurements (7) Appendix D Information Appendix (9)

Introduction

JJF 1032-2005 "optical radiation measurement terminology and definitions", JJF 1071-2010 "National Calibration Specifications writing rules ", JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement "constitute supporting this specification Basis for the development of normative work series. The specification for the first time to develop. Polarizing calibration specification

1 Scope

This standard applies to the use of polarized light measuring various types of polarizing material phase delay of the calibration. 2. References GB/T 26827-2011 wave plate phase delay calibration method of measuring apparatus For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Terms

3.1 phase delay phaseretardation When a bunch of polarized light beam is incident to the wave plates, broken down into the wave propagation along the original film direction but the direction of vibration perpendicular to each other Of o light and e light, due to the different propagation speed retardation caused. 3.2 polariscope polarimeter Instrument for measuring the phase delay, also known as phase delay measuring instrument, polarizing strain gauge.

4 Overview

Instrument is measuring the polarization of transparent plastic, glass and other transparent materials to light birefringence, and the phase delay Belated quantitative characterization instruments. Polarization analyzer consists of a light source, a polarizer, the sample compartment, an analyzer, a photodetector and a letter No part of the treatment. Figure 1 is a schematic diagram of a polarization analyzer. Figure 1 Schematic polarization analyzer Figure 1 polarizer, sample, the analyzer should be placed parallel to each other and perpendicular to the optical path. Polarizer, a sample analyzer Possessing at least one device can be rotated about the optical axis. Delay stage times with measuring equipment, the system should have a light source Two optical radiation can be used to measure the actual output and more different wavelengths. Measured by light line with the actual application requirements, commonly used wavelength of 532nm, 540nm, 546nm, 560nm, 565nm, 589nm, 632nm and the like.

5 Metrological characteristics

5.1 light spectrum half width

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1497-2014_English be delivered?

Answer: Upon your order, we will start to translate JJF 1497-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1497-2014_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1497-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.