US$349.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1497-2014: Calibration Specification for Polarimeters Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1497-2014 | English | 349 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Polarimeters
| Valid |
JJF 1497-2014
|
PDF similar to JJF 1497-2014
Standard similar to JJF 1497-2014 GB/T 43191 GB/T 15284 JJG 2059
Basic data Standard ID | JJF 1497-2014 (JJF1497-2014) | Description (Translated English) | Calibration Specification for Polarimeters | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | N21 | Word Count Estimation | 15,195 | Date of Issue | 11/17/2014 | Date of Implementation | 2/17/2015 | Quoted Standard | GB/T 26827-2011 | Regulation (derived from) | The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 No. 125 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to the use of polarized light measuring various types of polarizing material phase delay the calibration. |
JJF 1497-2014: Calibration Specification for Polarimeters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Polarimeters
People's Republic of China National Metrology Technical Specifications
Polarizing calibration specification
Issued on. 2014-11-17
2015-02-17 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Polarizing calibration specification
Focal point. the National Technical Committee on Optical metrology
The main drafting units. China Institute of Metrology
Shanghai Measurement and Testing Technology Research Institute
Participated in the drafting. national security glass and quartz glass Quality Supervision and Inspection Center
This specification committee commissioned by the National Optical measurement technology is responsible for interpreting
The main drafters of this specification.
Victor Fung Jin (China Institute of Metrology)
Zhengchun Di (China Institute of Metrology)
Xia Ming (Shanghai Institute of Measurement and Testing)
Drafters participate.
Wang Jing Jing (national security glass and quartz glass Quality Supervision and Inspection Center)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Terms (1)
3.1 phase delay (1)
3.2 polariscope (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 light spectrum half width (1)
5.2 the zero phase delay (2)
5.3 phase delay Repeatability (2)
5.4 phase delay indication error (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 standards and other measuring equipment (2)
7 calibration items and calibration methods (2)
7.1 light spectrum half width (2)
7.2 Instrument zero adjustment (3)
7.3 phase delay zero point drift (3)
7.4 phase delay indication error and repeatability (3)
8 calibration results expression (3)
9 Recalibration interval (4)
Appendix A polarizing recommended calibration original record format (5)
Appendix B Calibration Certificate-page format recommended (6)
Evaluation of Uncertainty Appendix C Calibration Indication Error polarization measurements (7)
Appendix D Information Appendix (9)
Introduction
JJF 1032-2005 "optical radiation measurement terminology and definitions", JJF 1071-2010 "National Calibration
Specifications writing rules ", JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement "constitute supporting this specification
Basis for the development of normative work series.
The specification for the first time to develop.
Polarizing calibration specification
1 Scope
This standard applies to the use of polarized light measuring various types of polarizing material phase delay of the calibration.
2. References
GB/T 26827-2011 wave plate phase delay calibration method of measuring apparatus
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 Terms
3.1 phase delay phaseretardation
When a bunch of polarized light beam is incident to the wave plates, broken down into the wave propagation along the original film direction but the direction of vibration perpendicular to each other
Of o light and e light, due to the different propagation speed retardation caused.
3.2 polariscope polarimeter
Instrument for measuring the phase delay, also known as phase delay measuring instrument, polarizing strain gauge.
4 Overview
Instrument is measuring the polarization of transparent plastic, glass and other transparent materials to light birefringence, and the phase delay
Belated quantitative characterization instruments. Polarization analyzer consists of a light source, a polarizer, the sample compartment, an analyzer, a photodetector and a letter
No part of the treatment. Figure 1 is a schematic diagram of a polarization analyzer.
Figure 1 Schematic polarization analyzer
Figure 1 polarizer, sample, the analyzer should be placed parallel to each other and perpendicular to the optical path. Polarizer, a sample analyzer
Possessing at least one device can be rotated about the optical axis. Delay stage times with measuring equipment, the system should have a light source
Two optical radiation can be used to measure the actual output and more different wavelengths.
Measured by light line with the actual application requirements, commonly used wavelength of 532nm, 540nm, 546nm, 560nm,
565nm, 589nm, 632nm and the like.
5 Metrological characteristics
5.1 light spectrum half width
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1497-2014_English be delivered?Answer: Upon your order, we will start to translate JJF 1497-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1497-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1497-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|