US$949.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1421-2013: Program of Pattern Evaluation of Carbon Monoxide Monitors Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1421-2013 | English | 949 |
Add to Cart
|
7 days [Need to translate]
|
Program of Pattern Evaluation of Carbon Monoxide Monitors
| Valid |
JJF 1421-2013
|
PDF similar to JJF 1421-2013
Basic data Standard ID | JJF 1421-2013 (JJF1421-2013) | Description (Translated English) | Program of Pattern Evaluation of Carbon Monoxide Monitors | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.020 | Word Count Estimation | 41,450 | Quoted Standard | JJG 915-2008; GB 12358-2006; GB/T 17626.2-2006; GB/T 17626.3-2006; GB/T 17626.4-2008 | Regulation (derived from) | AQSIQ Announcement No. 88, 2013; | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to: Non- mine operating environments carbon monoxide detector alarm (hereinafter referred to as "equipment") type evaluation. |
JJF 1421-2013: Program of Pattern Evaluation of Carbon Monoxide Monitors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Carbon Monoxide Monitors
People's Republic of China National Metrology Technical Specifications
Carbon monoxide detector alarm type evaluation outline
Issued on. 2013-07-04
2013-10-04 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Carbon monoxide detection alarm
Type Evaluation Outline
Focal point. the National Technical Committee on Environment stoichiometry
Drafting. Shanghai Institute of Measurement and Testing
China Testing Technology Research Institute
This specification technical committee commissioned by the National stoichiometric environment responsible for interpreting
Drafters of this specification.
Chen Lan (Shanghai Institute of Measurement and Testing)
Cai Jianhua (Shanghai Institute of Measurement and Testing)
Cheng Tao (Shanghai Institute of Measurement and Testing)
Liu (China Testing Technology Research Institute)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 to review the applicant must provide the technical information and test prototype (1)
4.1 Review of providing technical information (1)
4.2 provide a test prototype (1)
5 legal management requirements (2)
5.1 units of measurement (2)
5.2 accuracy (maximum permissible error) (2)
5.3 legal metrology marking and identification of measuring instruments (2)
5.4 Installation flag (2)
5.5 Other (2)
6 measurement requirements (2)
6.1 Measurement range (2)
6.2 Indication error (2)
6.3 Repeatability (2)
Drift 6.4 (2)
6.5 Response Time (2)
7 General technical requirements (3)
7.1 Appearance (3)
7.2 alarm function and alarm setting error (3)
7.3 Long-term stability (3)
7.4 adaptive power supply voltage (3)
7.5 Security Environment (3)
7.6 Climate (3)
7.7 mechanical environment (4)
7.8 Electromagnetic compatibility (4)
8 pattern evaluation item list (5)
9 pilot projects test method and conditions (6)
9.1 metrological requirements (6)
9.2 General Requirements (9)
Assessed and treated 10 types of evaluation results (15)
11 original record format type evaluation (15)
Original record format in Appendix A (16)
Introduction
This outline is based on JJF 1015-2002 "Measuring Instruments type evaluation and type approval of universal norms" and
JJF 1016-2009 "Measuring Instruments type evaluation outline guidelines for the preparation" Writing.
Technical indicators are based on this syllabus JJG915-2008 "carbon monoxide detector alarm", GB 12358-2006
"Workplace environment gas detection alarm general technical requirements", GB/T 17626.2-2006 "Electromagnetic Compatibility Test
Test and measurement techniques - Electrostatic discharge immunity test ", GB/T 17626.3-2006" Electromagnetic compatibility testing and measurement
Technical RFEMS test "and GB/T 17626.4-2008" Electromagnetic compatibility testing and measurement
Technical electrical fast transient burst immunity test "and other technical regulations.
This outline is the first release.
Carbon monoxide detector alarm type evaluation outline
1 Scope
This type of evaluation framework applicable to non-mine operating environment used in carbon monoxide detector alarm device (hereinafter referred to as
"Instrument") of pattern evaluation.
2. References
JJG915-2008 carbon monoxide detector alarm
GB 12358-2006 workplace environment gas detection alarm general technical requirements
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test
GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity
test
These documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply in this outline, however, encourage
Whether the latest versions of these files according to the parties that this outline agreement. For undated references the
, The latest versions apply to this outline.
3 Overview
Carbon monoxide detector alarm is mainly used for monitoring the concentration of carbon monoxide gas in the environment, used in the production process of human
Body protection. When the gas concentration exceeds a set value, the instrument emits an alarm signal. Instrument consists of sensors,
And a display section composed of electronic components, the sensor converts the carbon monoxide gas concentration in the environment into electrical signals, electronically
Processing means, to a concentration value is displayed. Depending on the sampling mode, the instrument can be divided into diffusion and inhaled.
Depending on the use of the instrument can be divided into portable and stationary.
4 applicant must provide technical information and test prototype review
4.1 Review of providing technical information
a) prototype photos;
b) product standards (including test methods);
c) assembly diagram, schematic diagram and major components;
d) Instructions;
e) test report made by manufacturing unit or technical bodies;
f) Where the products marked with explosion-proof feature should provide proof certificate.
4.2 provides experimental prototype
The applicant should provide their own production prototype. The applicant can apply for a single product, you can also press the line
Out products to apply. Where the application as a single product, under normal circumstances should be provided 3 prototype. Fixed-mounted instrument
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1421-2013_English be delivered?Answer: Upon your order, we will start to translate JJF 1421-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1421-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1421-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|