US$329.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1328-2011: Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge Status: Valid JJF 1328: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1328-2011 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge
| Valid |
JJF 1328-2011
|
JJF 1328-1990 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Operating Technical Norm of Secondary Standard of Laser Power in the Middle Level
| Obsolete |
JJF 1328-1990
|
PDF similar to JJF 1328-2011
Basic data Standard ID | JJF 1328-2011 (JJF1328-2011) | Description (Translated English) | Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Classification of International Standard | 17.100 | Word Count Estimation | 14,160 | Date of Issue | 2011-12-28 | Date of Implementation | 2012-03-28 | Quoted Standard | JJG 52-1999; JJG 913-1996; GB/T 7899-2006; GB/T 25112-2010 | Regulation (derived from) | AQSIQ Announcement No. 205 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the gas gauge with Bourdon tube pressure reducer (hereinafter referred to as the gas pressure reducer) calibration. |
JJF 1328-2011: Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge
People's Republic of China National Metrology Technical Specifications
Bourdon tube pressure gauge with gas
Regulator calibration specifications
Issued on. 2011-12-28
2012-03-28 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Bourdon tube pressure gauge with gas
Regulator calibration specifications
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on December 28, 2011, and from
From March 28, 2012 into effect.
Focal point. the National Technical Committee of pressure measurement
Main drafting unit. Liaoning Provincial Institute of Metrology
Henan Institute of Metrology
Beijing Const Instrument Technology Co., Ltd.
Participated in the drafting unit. Fuxin City metrological verification tests
This specification commissioned the National Technical Committee of pressure measurement shall be interpreted
The main drafters of this specification.
Zhang Zijian (Liaoning Provincial Institute of Metrology)
Wang Bin (Liaoning Provincial Institute of Metrology)
In Xiaobai (Liaoning Provincial Institute of Metrology)
Xiao-full (Henan Institute of Metrology)
He Xin (Beijing Const Instruments Technology Co., Ltd.)
Drafters participate.
Water-Chi (Fuxin City metrological verification tests)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Terms and Definitions (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Zero (1)
5.2 Indication error (2)
5.3 Return error (2)
5.4 Displacement tap (2)
5.5 pointer deflection stability (2)
5.6 sealing (2)
5.7 safety valve (2)
5.8 Additional features (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 Standard device and other equipment (2)
7 calibration items and calibration methods (3)
Zero 7.1 (3)
7.2 Indication error (3)
7.3 Return error (3)
7.4 Tapping displacement (3)
7.5 pointer deflection stability (3)
7.6 sealing (4)
7.7 Safety valve (4)
7.8 Additional features (4)
8 calibration results (4)
9 Recalibration interval (4)
Appendix A calibration certificate (within the page) format (5)
Appendix B recording format (6)
Appendix C gas pressure reducer Pressure Indication Error of Measurement Uncertainty instances (7)
Bourdon tube pressure gauge with gas
Regulator calibration specifications
1 Scope
This standard applies to gas pressure reducer with Bourdon tube pressure gauge (hereinafter referred to as gas pressure reducer) calibration.
2 Citations
JJG52-1999 spring tube general pressure gauges, pressure vacuum gauge and vacuum gauge
JJG913-1996 buoy type oxygen inhaler
GB/T 7899-2006 welding, cutting and allied processes cylinder pressure reducer
GB/T 25112-2010 welding, cutting and allied processes gauge
When using this specification it should be noted that using the currently valid version of the documents cited.
3 Terms and Definitions
3.1 Gas pressure reducer pressureregulator
The usual variable inlet pressure is adjusted to the extent possible a stable outlet pressure device.
3.2 Rated inlet pressure (p1) ratedinletpressure
Maximum inlet pressure reducer design.
3.3 rated outlet pressure (p2) ratedoutletpressure
The maximum outlet pressure regulator designs.
3.4 safety valve opening pressure (pRV) pressureforthepressure-reliefvalveduringdischargetest
Safety valve opening pressure limit, the value. pRV = 2p2, acetylene gas pressure reducer in any case should pRV
Equal to 0.3MPa.
4 Overview
Gas pressure reducer is mainly used to maintain a constant outlet pressure and oxygen, acetylene, nitrogen, hydrogen and other high-pressure gas source
Pressure, with lower inlet pressure, outlet pressure remain stable two effects.
Gas pressure reducer main unit, safety valve, pressure gauge and other parts of the body, pressure regulator components. When screwing the regulator
When the screw jack by making the shutter decompression valve for varying degrees of opening and closing, or adjusting the degree of vacuum gas stop
Stop gas supply. On the body may be provided with a pressure reducer low pressure chamber communicating safety valve when the pressure reducer failure, low
Pressure chamber pressure exceeds the safety valve opening pressure, the valve opens, the air escapes through the safety valve.
5 Metrological characteristics
5.1 Zero
5.1.1 pressure gauge with stop pin, in the absence of pressure, the pointer should immediately stop pin, "indent" in Table 1 should not exceed
The absolute value of a predetermined tolerance.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1328-2011_English be delivered?Answer: Upon your order, we will start to translate JJF 1328-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1328-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1328-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1328-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1328-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|