HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1328-2011 English PDF

US$329.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1328-2011: Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge
Status: Valid

JJF 1328: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1328-2011English329 Add to Cart 3 days [Need to translate] Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge Valid JJF 1328-2011
JJF 1328-1990English199 Add to Cart 2 days [Need to translate] Operating Technical Norm of Secondary Standard of Laser Power in the Middle Level Obsolete JJF 1328-1990

PDF similar to JJF 1328-2011


Standard similar to JJF 1328-2011

GB/T 36126   JJF 1368   GB/T 1885   JJF 1336   JJF 1333   JJF 1320   

Basic data

Standard ID JJF 1328-2011 (JJF1328-2011)
Description (Translated English) Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 14,160
Date of Issue 2011-12-28
Date of Implementation 2012-03-28
Quoted Standard JJG 52-1999; JJG 913-1996; GB/T 7899-2006; GB/T 25112-2010
Regulation (derived from) AQSIQ Announcement No. 205 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the gas gauge with Bourdon tube pressure reducer (hereinafter referred to as the gas pressure reducer) calibration.

JJF 1328-2011: Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Pressure Regulators with Bourdon Tube Pressure Gauge People's Republic of China National Metrology Technical Specifications Bourdon tube pressure gauge with gas Regulator calibration specifications Issued on. 2011-12-28 2012-03-28 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Bourdon tube pressure gauge with gas Regulator calibration specifications This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on December 28, 2011, and from From March 28, 2012 into effect. Focal point. the National Technical Committee of pressure measurement Main drafting unit. Liaoning Provincial Institute of Metrology Henan Institute of Metrology Beijing Const Instrument Technology Co., Ltd. Participated in the drafting unit. Fuxin City metrological verification tests This specification commissioned the National Technical Committee of pressure measurement shall be interpreted The main drafters of this specification. Zhang Zijian (Liaoning Provincial Institute of Metrology) Wang Bin (Liaoning Provincial Institute of Metrology) In Xiaobai (Liaoning Provincial Institute of Metrology) Xiao-full (Henan Institute of Metrology) He Xin (Beijing Const Instruments Technology Co., Ltd.) Drafters participate. Water-Chi (Fuxin City metrological verification tests)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Terms and Definitions (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 Zero (1) 5.2 Indication error (2) 5.3 Return error (2) 5.4 Displacement tap (2) 5.5 pointer deflection stability (2) 5.6 sealing (2) 5.7 safety valve (2) 5.8 Additional features (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 Standard device and other equipment (2) 7 calibration items and calibration methods (3) Zero 7.1 (3) 7.2 Indication error (3) 7.3 Return error (3) 7.4 Tapping displacement (3) 7.5 pointer deflection stability (3) 7.6 sealing (4) 7.7 Safety valve (4) 7.8 Additional features (4) 8 calibration results (4) 9 Recalibration interval (4) Appendix A calibration certificate (within the page) format (5) Appendix B recording format (6) Appendix C gas pressure reducer Pressure Indication Error of Measurement Uncertainty instances (7) Bourdon tube pressure gauge with gas Regulator calibration specifications

1 Scope

This standard applies to gas pressure reducer with Bourdon tube pressure gauge (hereinafter referred to as gas pressure reducer) calibration.

2 Citations

JJG52-1999 spring tube general pressure gauges, pressure vacuum gauge and vacuum gauge JJG913-1996 buoy type oxygen inhaler GB/T 7899-2006 welding, cutting and allied processes cylinder pressure reducer GB/T 25112-2010 welding, cutting and allied processes gauge When using this specification it should be noted that using the currently valid version of the documents cited.

3 Terms and Definitions

3.1 Gas pressure reducer pressureregulator The usual variable inlet pressure is adjusted to the extent possible a stable outlet pressure device. 3.2 Rated inlet pressure (p1) ratedinletpressure Maximum inlet pressure reducer design. 3.3 rated outlet pressure (p2) ratedoutletpressure The maximum outlet pressure regulator designs. 3.4 safety valve opening pressure (pRV) pressureforthepressure-reliefvalveduringdischargetest Safety valve opening pressure limit, the value. pRV = 2p2, acetylene gas pressure reducer in any case should pRV Equal to 0.3MPa.

4 Overview

Gas pressure reducer is mainly used to maintain a constant outlet pressure and oxygen, acetylene, nitrogen, hydrogen and other high-pressure gas source Pressure, with lower inlet pressure, outlet pressure remain stable two effects. Gas pressure reducer main unit, safety valve, pressure gauge and other parts of the body, pressure regulator components. When screwing the regulator When the screw jack by making the shutter decompression valve for varying degrees of opening and closing, or adjusting the degree of vacuum gas stop Stop gas supply. On the body may be provided with a pressure reducer low pressure chamber communicating safety valve when the pressure reducer failure, low Pressure chamber pressure exceeds the safety valve opening pressure, the valve opens, the air escapes through the safety valve.

5 Metrological characteristics

5.1 Zero 5.1.1 pressure gauge with stop pin, in the absence of pressure, the pointer should immediately stop pin, "indent" in Table 1 should not exceed The absolute value of a predetermined tolerance.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1328-2011_English be delivered?

Answer: Upon your order, we will start to translate JJF 1328-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1328-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1328-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1328-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1328-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.