US$509.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1326-2011: Calibration Specification for Mass Comparators Status: Valid JJF 1326: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1326-2011 | English | 509 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Mass Comparators
| Valid |
JJF 1326-2011
|
JJF 1326-1990 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
(30 to 300 watts of laser power reference operating technical specifications)
| Obsolete |
JJF 1326-1990
|
PDF similar to JJF 1326-2011
Basic data Standard ID | JJF 1326-2011 (JJF1326-2011) | Description (Translated English) | Calibration Specification for Mass Comparators | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Classification of International Standard | 17.060 | Word Count Estimation | 22,220 | Date of Issue | 2011-11-30 | Date of Implementation | 2012-03-01 | Quoted Standard | JJG 99-2006; OIML R111-1; EA-10/18; DKD-R-7-1 | Regulation (derived from) | State Administration of Quality Supervision, Inspection and Quarantine No. 202 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to all types of mass comparators (hereinafter referred to as comparator) calibration. |
JJF 1326-2011: Calibration Specification for Mass Comparators---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Mass Comparators
People's Republic of China National Metrology Technical Specifications
Mass Comparators calibration specification
Issued on. 2011-11-30
2012-03-01 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Mass Comparators calibration specification
forMassComp
arators
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on November 30, 2011, and from
From March 1, 2012 into effect.
Focal point. the quality and density measurement technology committee
The main drafting units. China Institute of Metrology
Beijing Institute of Metrology detection
Guangdong Provincial Institute of Metrology
Participated in the drafting unit. China Aviation Industry Corporation Beijing Great Wall Institute of Measurement and Testing Technology
China Testing Technology Research Institute
Shanghai Measurement and Testing Technology Research Institute
Mettler - Toledo Instruments (Shanghai) Co., Ltd.
This specification by the national mass, density measurement technical committee responsible for the interpretation
The main drafters of this specification.
Yao Hong (China Institute of Metrology)
Chen Xue (Beijing Institute of Metrology detection)
Wang Weizhong (Guangdong Institute of Metrology)
Drafters participate.
Zhangze Guang (China Aviation Industry Corporation Beijing Great Wall Measurement and Testing Technology Institute
The study)
Su Yi (Shanghai Institute of Measurement and Testing)
Party is strong (China Testing Technology Research Institute)
Li Yong (Mettler - Toledo Instruments (Shanghai) Co., Ltd.)
table of Contents
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
3.1 The term (1)
3.2 Symbol Table (2)
3.3 units of measurement (3)
4 Overview (3)
Principle 4.1 (3)
Use 4.2 (3)
4.3 Structure (3)
5 Metrological characteristics (4)
5.1 Repeatability (4)
5.2 partial load (4)
5.3 Local indication error (4)
6 calibration conditions (4)
6.1 standard weight (4)
6.2 Other relevant measuring measuring instruments (5)
6.3 Calibration environmental conditions (5)
6.4 Power supply (6)
6.5 Calibration of the cleaning process before the comparator (6)
6.6 Comparator storage time (6)
7 calibration items and calibration methods (6)
7.1 calibration items (6)
7.2 Calibration method (6)
8 calibration results (10)
9 Recalibration interval (10)
Appendix A Measurement of Uncertainty Evaluation Examples (11)
Appendix B mass comparator calibration certificate page format (13)
Appendix C Mass Comparators calibration table format recommended by the original records (14)
Mass Comparators calibration specification
1 Scope
This standard applies to all types of mass comparator (hereinafter referred to as comparator) calibration.
2. References
This specification references the following documents.
JJG99-2006 weight
OIMLR111-1 (E1, E2, F1, F2, M1, M1-2, M2, M2-3, M3 classified weights of the first portion
Score. metering technology requirements (2004 Edition) (WeightsofclassesE1, E2, F1, F2, M1, M1-2, M2,
M2-3andM3, Part 1. Metrologicalandtechnicalrequirements.Edition2004 (E))
EA-10/18 EU non-automatic weighing instrument calibration Details (Guidelinesonthecalibrationofnon-automatic
weightinginstruments)
Calibration DKD-R-7-1 Non-automatic electronic measurement instruments (released in 1998) (Calibrationofnon-auto-
maticelectronicweighinginstruments)
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
3.1 Terms
3.1.1 The maximum carrying capacity maximumcapacity (Max)
For the full range of electronic weighing comparator, a measure for the instrument can achieve the maximum effect of electronic weighing; for
Plus some electronic weighing range tared weight of the comparator, that measure instrument can achieve the maximum tare effect.
3.1.2 actual scale actualinterval (d)
Expressed in units of mass, it shows the difference between two adjacent values.
3.1.3 single quality measure range comparator singlerangemasscomparator
Over the entire range of measurement, only a fixed actual scale d mass comparator. Referred to as. Single-ratio range
Representing an instrument.
3.1.4 Multi-measure quality range comparator multiplerangemasscomparator
For only a pan of mass comparator having a plurality of from 0.00 to maximum load of the measuring range, and each
Measurement range and having different values of the actual scale of the mass comparator. Abbreviations. multi-range comparator - reference name
Word terms.
Mass Comparators multipleintervalmasscomparator 3.1.5 multi-interval values
Within the entire weighing range is divided into a plurality of actual scale to measure the different local scope, and can be based on actual scale
The quality of the applied loads automatically converted comparator. Acronym multi-interval comparator.
3.1.6 The actual number of divisions numberofactualinterval
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1326-2011_English be delivered?Answer: Upon your order, we will start to translate JJF 1326-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1326-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1326-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1326-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1326-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|