US$329.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1290-2011: Calibration specification for Particulate Analyzer Status: Valid JJF 1290: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1290-2011 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Calibration specification for Particulate Analyzer
| Valid |
JJF 1290-2011
|
JJF 1290-1990 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
O.T.N. of Contingent Primary Standard for Alternating-Current Electrical Energy
| Obsolete |
JJF 1290-1990
|
PDF similar to JJF 1290-2011
Basic data Standard ID | JJF 1290-2011 (JJF1290-2011) | Description (Translated English) | Calibration specification for Particulate Analyzer | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A60 | Classification of International Standard | 17.18 | Word Count Estimation | 14,145 | Date of Issue | 6/14/2011 | Date of Implementation | 9/14/2011 | Quoted Standard | JJF 1001-1998; JJF 1094-2002; PRC Pharmacopoeia (2010) | Regulation (derived from) | National AQSIQ 2011 No. 90 Notice | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the use of insoluble particles assay (resist method), measuring particle size in the range of 2��m ~ 100 ��m, particle concentration range for each 1mL containing 10 to 100 000 particles of particle detector calibration. |
JJF 1290-2011: Calibration specification for Particulate Analyzer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration specification for Particulate Analyzer
People's Republic of China National Metrology Technical Specifications
Particle Detector Calibration Specification
Issued on. 2011-06-14
2011-09-14 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Particle Detector Calibration Specification
zer
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on June 14, 2011, and from
From September 14, 2011 into effect.
Focal point. the National Technical Committee on Optical metrology
Main drafting unit. Liaoning Provincial Institute of Metrology
China Testing Technology Research Institute
Participated in the drafting unit. Dalian metrological verification tests
This specification committee commissioned by the National Optical measurement technology is responsible for interpreting
The main drafters of this specification.
Aiming Ze (Liaoning Provincial Institute of Metrology)
Xiao Zhe (Liaoning Provincial Institute of Metrology)
Li Xiaobin (China Testing Technology Research Institute)
Tao Cheng (Liaoning Provincial Institute of Metrology)
Drafters participate.
Tang Jing (Dalian metrological verification tests)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Overview (1)
4 Metrological characteristics (2)
Sample volume relative deviation of 4.1 (2)
The relative error of 4.2 particle counting (2)
4.3 particle counting reproducibility (2)
Resolution 4.4 channel (2)
Calibration Condition 5 (2)
5.1 Calibration Environment (2)
5.2 standard devices and other equipment (2)
6 calibration items and calibration methods (2)
6.1 Calibration before the test (2)
Sample volume relative deviation of 6.2 (2)
The relative error of 6.3 particle counting (3)
6.4 particle counting reproducibility (3)
Resolution 6.5 channel (3)
7 Calibration Results The expression (4)
8 Recalibration interval (4)
Appendix A calibration record format (5)
Appendix B Calibration Certificate page format (6)
Appendix C Evaluation of Uncertainty in Measurement Example (7)
Particle Detector Calibration Specification
1 Scope
This standard applies to the use of insoluble particles assays (resist method), measuring particle size in the range of 2μm ~ 100μm,
Particle concentration in the range of 1mL each containing 10 to 100 000 particles of particle detector calibration.
2 Citations
This specification references the following documents.
JJF 1001-1998 common measurement terms and definitions
JJF 1094-2002 measuring instrument characteristics evaluation
People's Republic of China Pharmacopoeia (2010 edition)
When using this specification it should be noted that using the currently valid version of the documents cited.
3 Overview
Particle detector in accordance with the principles of the photoresist method, for checking intravenous injection (injection solution type, non-injectable
Sterile powders, concentrated solution for injection) for intravenous injection and sterile bulk drugs, insoluble particles size and number of divisions
Analysis of the instrument.
When the liquid particles through a narrow detection zone, the liquid flow perpendicular to the incident, since the particle barrier
Block weakened, thus reducing the sensor output signal, such a signal proportional to the change in cross-sectional area of the particles, by
Data processing, to calculate the size and number of particles.
Particle detector consists of a light source part of the system, detection system, a data processing system components.
1 a schematic diagram Fundamentals
A- source system; B- detecting system; the C-data processing system
Note. The number of particles in a liquid, also known as particle concentration, per 1mL containing the number of particles with the symbol "particles/ml" said.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1290-2011_English be delivered?Answer: Upon your order, we will start to translate JJF 1290-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1290-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1290-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1290-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1290-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|