HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1270-2010 English PDF

US$459.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1270-2010: Calibration specification for temperature/humidity/vibration combined environmental testing system
Status: Valid

JJF 1270: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1270-2010English459 Add to Cart 4 days [Need to translate] Calibration specification for temperature/humidity/vibration combined environmental testing system Valid JJF 1270-2010
JJF 1270-1990English199 Add to Cart 2 days [Need to translate] O.T.N of the Secondary Standard for Coupler Reciprocity Method Acoustical Pressure Obsolete JJF 1270-1990

PDF similar to JJF 1270-2010


Standard similar to JJF 1270-2010

GB/T 36126   JJF 1368   GB/T 1885   JJF 1261.10   JJF 1271   JJF 1269   

Basic data

Standard ID JJF 1270-2010 (JJF1270-2010)
Description (Translated English) Calibration specification for temperature/humidity/vibration combined environmental testing system
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.160
Word Count Estimation 20,230
Date of Issue 2010-12-30
Date of Implementation 2011-04-01
Quoted Standard JJG 948-1999; JJG 1000-2005; JJF 1059-1999; JJF 1156-2006; GB/T 2298-1991; GB/T 5170.1-2008; GB/T 5170.2-2008
Regulation (derived from) AQSIQ Announcement No. 3 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to product reliability test temperature, humidity, vibration comprehensive environmental testing calibration of the system, also applies to the production environment and environmental stress screening test temperature, vibration system of integrated environmental calibration test face. The temperature for the product environmental test chamber, temperature and humidity chamber and rapid temperature chamber can also be calibrated with reference to the implementation of this specification.

JJF 1270-2010: Calibration specification for temperature/humidity/vibration combined environmental testing system


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration specification for temperature/humidity/vibration combined environmental testing system People's Republic of China National Metrology Technical Specifications Temperature, humidity, vibration integrated environmental Calibration Test System Specifications Issued on. 2010-12-30 2011-04-01 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Temperature, humidity, vibration integrated environmental Calibration Test System Specifications stem This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on December 30, 2010, and from From April 1, 2011 implementation. Focal point. the National Technical Committee of shock and vibration measurement speed The main drafting units. China Aviation Industry Corporation Beijing Great Wall Measurement and Testing Technology Institute The study Beijing Zhongyuan ring test Mechanical and Electrical Equipment Co., Ltd. Participated in the drafting unit. Chongqing Yinhe Experimental Instrument Co., Ltd. The shock and vibration specification by the National Technical Committee is responsible for interpretation of measurement speed The main drafters of this specification. Xu Xiaomei (China Aviation Industry Corporation Beijing Great Wall Institute of Measurement and Testing Technology) I had (China Aviation Industry Corporation Beijing Great Wall Institute of Measurement and Testing Technology) Wu Fang (China Aviation Industry Corporation Beijing Great Wall Institute of Measurement and Testing Technology) Jason Hu (Beijing Zhongyuan ring test Mechanical and Electrical Equipment Co., Ltd.) Drafters participate. Wang Yongqiang (Beijing Zhongyuan ring test Mechanical and Electrical Equipment Co., Ltd.) Wang Huabin (Chongqing Yinhe Experimental Instrument Co., Ltd.)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Terms (1) 4 Overview (1) 5 Metrological characteristics (2) 6 calibration conditions (3) 6.1 chamber calibration status (3) 6.2 Status Vibration test equipment (3) 6.3 Environmental conditions during calibration (3) 6.4 load conditions during calibration (3) 6.5 instrument calibration requirements (3) 7 calibration items (4) Calibration Method 8 (5) 8.1 average noise calibration work (5) 8.2 Calibration chamber temperature deviation (5) 8.3 Temperature fluctuation calibration chamber (6) 8.4 chamber temperature uniformity calibration (6) 8.5 Temperature indicator represents the value of error correction (6) Rate of temperature change 8.6 Calibration chamber (7) 8.7 calibration test chamber airflow Winds (8) 8.8 Deviation relative humidity calibration chamber (9) 8.9 Relative humidity indicator represents the value of the calibration error (10) 8.10 minimum dew point temperature calibration chamber (10) 8.11 temperature cycling, vibration acceleration amplitude calibration error indication (10) 8.12 Additional shaker table and the table acceleration acceleration response uniformity calibration (12) 8.13 vibration control channel calibration consistency (13) 9 calibration results expression (13) 10 Recalibration interval (14) A calibration certificate within the page format appendix (15) Temperature, humidity, vibration integrated environmental Calibration Test System Specifications

1 Scope

This instruction applies to product reliability test of temperature, humidity, vibration integrated test system calibration, are also suitable Temperature and environmental stress screening products for environmental testing, calibration, vibration comprehensive environmental testing system. Products for ring Environmental test chamber temperature, chamber temperature and humidity chamber and rapid temperature changes can also be implemented with reference to the calibration of the specification.

2 Citations

JJG948-1999 digital electric vibration test system test procedures JJG1000-2005 electric horizontal vibration test stand test procedures JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement JJF 1156-2006 vibration, shock, speed measurement terms and definitions GB/T 2298-1991 Mechanical vibration and shock term GB/T 5170.1-2008 Environmental testing for electric and electronic test equipment - General GB/T 5170.2-2008 Environmental testing for electric and electronic test equipment Temperature test equipment When using this specification it should be noted that using the currently valid version of the documents cited.

3 Terms

3.1 steady state steadystate Within the chamber workspace all measuring points parameters change chamber volume to achieve performance requirements of their own status. 3.2 indicating instrument indication error indicatedvalueerrorofindicatedmeter Chamber in stable condition, within the specified time, the chamber indicator represents the arithmetic mean value and All measurement points measured value difference arithmetic average of the test chamber within the workspace. Rate of temperature change 3.3 temperaturevariationrate Within a predetermined temperature range, the working chamber of a predetermined point in space temperature monotonic rise (or fall) When the total amount of temperature change in the ratio of process time experience. There are three different rate of temperature change of the definition, i.e., The maximum average rate of temperature change, the whole average rate of temperature change and transient rate of temperature change with ℃/min represents. 3.4 acceleration amplitude indication error indicatedvalueerrorofaccelerationamplitude Accelerometer control differential acceleration indication of the measured values with the accelerometer calibration.

4 Overview

Temperature, humidity, vibration (or temperature, vibration) integrated test system (referred to as a comprehensive environmental testing system EC) is to produce temperature and (or) humidity temperature and humidity (or temperature) chamber (referred to as the chamber) and Vibration test equipment to produce vibration environments (referred to as shakers) integrated together, see Figure 1.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1270-2010_English be delivered?

Answer: Upon your order, we will start to translate JJF 1270-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1270-2010_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1270-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1270-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1270-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.