JJF 1263-2010: Calibration Specification for the Alarmer Detector of Sulfur Hexafluoride
Status: Valid

JJF 1263: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1263-2010English299 Add to Cart 3 days [Need to translate] Calibration Specification for the Alarmer Detector of Sulfur Hexafluoride Valid JJF 1263-2010
JJF 1263-1990English279 Add to Cart 3 days [Need to translate] O.T.N. of the Primary Standard for Low Frequency Bibration in Horizontal Direction Obsolete JJF 1263-1990

PDF similar to JJF 1263-2010


Standard similar to JJF 1263-2010

JJG 1094   JJF 1424   JJF 1363   JJF 1891   JJF 1272   JJF 1267   

Basic data

Standard ID JJF 1263-2010 (JJF1263-2010)
Description (Translated English) Calibration Specification for the Alarmer Detector of Sulfur Hexafluoride
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A61
Classification of International Standard 17.020
Word Count Estimation 13,179
Date of Issue 2010-09-06
Date of Implementation 2011-03-06
Older Standard (superseded by this standard) JJG 914-1996
Regulation (derived from) AQSIQ Announcement No. 100 of 2010
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to sulfur hexafluoride Detectors Alarm (hereinafter referred to as the instrument) for calibration. The leak detector is used to detect sulfur hexafluoride and sulfur hexafluoride, and other related testing equipment, can refer to all the items in this specification or part of the project for calibration.

JJF 1263-2010: Calibration Specification for the Alarmer Detector of Sulfur Hexafluoride

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for the Alarmer Detector of Sulfur Hexafluoride People's Republic of China National Metrology Technical Specifications Sulfur hexafluoride alarm detector calibration specification Issued on. 2010-09-06 2011-03-06 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Sulfur hexafluoride alarm detector calibration specification Instead of JJG914-1996 This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 6, 2010, and from From March 6, 2011 into effect. Focal point. the National Technical Committee on Environment stoichiometry The main drafting units. China Institute of Metrology China Testing Technology Research Institute Participated in the drafting. Jiangxi Institute of Measurement and Testing Guangzhou Institute of Metrology The specification of the National Technical Committee on Environment stoichiometric responsible for interpreting The main drafters of this specification. Chen Yonghua (China Institute of Metrology) Han Bridge (China Institute of Metrology) Liu (China Testing Technology Research Institute) Drafters participate. Yang Yu Zhe (Jiangxi Institute of Measurement and Testing) Cao Zhigang (China Institute of Metrology) Chen Wei Qing (Guangzhou Institute of Metrology)

table of Contents

1 Scope (1) 2 Overview (1) 3 Metrological characteristics (2) 3.1 Measurement range (2) 3.2 Indication error (2) 3.3 Repeatability (2) 3.4 Response Time (2) 3.5 alarm function and alarm (2) 3.6 The minimum detection limit (2) 3.7 Alarm response time (2) Drift 3.8 (2) Calibration Condition 4 (2) 4.1 environmental conditions (2) 4.2 calibration of measuring instruments and equipment (2) 5 calibration items and calibration methods (3) 5.1 calibration items (3) 5.2 Calibration method (3) 6 calibration expression (5) 7 Recalibration interval (5) Appendix A sulfur hexafluoride alarm detector calibration records (6) Appendix B Certificate page format (8) Sulfur hexafluoride alarm detector calibration specification

1 Scope

This instruction applies to sulfur hexafluoride alarm detector (hereinafter referred to as equipment) calibration. For the detection of sulfur hexafluoride Leak detection and other related instruments and sulfur hexafluoride, can refer to this specification all or part of the project calibration.

2 Overview

Sulfur hexafluoride alarm detector widely used in electricity, power, metallurgy, scientific research and research use sulfur hexafluoride gas The field of sulfur hexafluoride gas concentration analysis, testing, leak detection or alarm. UV detection principles generally electricity Release negative voltage corona type, a partial vacuum and electronic capturing. Instrument consists of a light source, ionized, gas and circuit system. Among them, the principle of UV ionization type instruments such as 1 shown in FIG. Photoelectric surface irradiation mercury emitted photoelectrons, when measured ambient air from the photoelectric surface and an accelerating electrode Flows between outdated, optoelectronics will be attached to the O2 and SF6 molecules in the gas to be measured, the formation of negative ions, due to the increase - Speed electrode between the accelerating electrode and the photoelectric surface form a current. Under the influence of modulated optical signal, since the air The O2 and SF6 molecules of different moving speed, when the concentration of SF6 molecules changes, the current phase occurs Changes, by measuring the change in phase, and the concentration of SF6 gas measurements. Figure 1 Schematic UV ionization

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1263-2010_English be delivered?

Answer: Upon your order, we will start to translate JJF 1263-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1263-2010_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1263-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1263-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1263-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.