US$1349.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1261.9-2022: Rules of Metrology Testing for Energy Efficiency of Domestic Gas Instantaneous Water Heaters and Gas Fired Heating and Hot Water Combi-boilers Status: Valid JJF 1261.9: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1261.9-2022 | English | 1349 |
Add to Cart
|
7 days [Need to translate]
|
Rules of Metrology Testing for Energy Efficiency of Domestic Gas Instantaneous Water Heaters and Gas Fired Heating and Hot Water Combi-boilers
| Valid |
JJF 1261.9-2022
|
JJF 1261.9-2013 | English | RFQ |
ASK
|
8 days [Need to translate]
|
Rules of Metrology Testing for Energy Efficiency Label of Domestic Gas Instantaneous Water Heater and Gas Fired Heating and Hot Water Combi-boilers
| Obsolete |
JJF 1261.9-2013
|
Standard similar to JJF 1261.9-2022 JJF 1261.10 JJF 1261.27 JJF 1261.5
Basic data Standard ID | JJF 1261.9-2022 (JJF1261.9-2022) | Description (Translated English) | Rules of Metrology Testing for Energy Efficiency of Domestic Gas Instantaneous Water Heaters and Gas Fired Heating and Hot Water Combi-boilers | Sector / Industry | Metrology & Measurement Industry Standard | Word Count Estimation | 61,685 | Date of Issue | 2022-04-29 | Date of Implementation | 2022-10-29 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1261.9-2022: Rules of Metrology Testing for Energy Efficiency of Domestic Gas Instantaneous Water Heaters and Gas Fired Heating and Hot Water Combi-boilers ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rules of Metrology Testing for Energy Efficiency of Domestic Gas Instantaneous Water Heaters and Gas Fired Heating and Hot Water Combi-boilers
National Metrology Technical Specifications of the People's Republic of China
Household gas instant water heater and gas heating water heater
Energy Efficiency Measurement and Testing Rules
Combi-boilers
Released on 2022-04-29
Implementation on 2022-10-29
Released by the State Administration for Market Regulation
Household Gas Instant Water Heater and Gas Heating
Water heater energy efficiency measurement and testing rules
Replace JJF 1261.9-2013
Responsible Unit. National Technical Committee on Energy and Resources Measurement
Energy Efficiency Labeling Metrology Sub-Technical Committee
Main drafting unit. Jiangsu Institute of Metrology
Jiangsu Product Quality Supervision and Inspection Research Institute
Participating in the drafting unit. Guangdong Institute of Metrology
Guangdong Wanhe New Electric Co., Ltd.
Qingdao Economic and Technological Development Zone Haier Water Heater Co., Ltd.
Shanghai Mengdi Testing Technology Co., Ltd.
This specification entrusts the Energy Efficiency Labeling and Metrology Subcommittee of the National Energy and Resources Metrology Technical Committee
responsible for explaining
The main drafters of this specification.
Mao Shuonan (Jiangsu Institute of Metrology)
Zhou Aihua (Jiangsu Provincial Institute of Product Quality Supervision and Inspection)
Shao Yuda (Jiangsu Institute of Metrology)
Participating drafters.
Wu Zhongjie (Guangdong Institute of Metrology)
Jiang Xianming (Guangdong Wanhe New Electric Co., Ltd.)
Cao Guanzhong (Qingdao Economic and Technological Development Zone Haier Water Heater Co., Ltd.)
Jiang Ming (Shanghai Mengdi Testing Technology Co., Ltd.)
Table of contents
Introduction (Ⅲ)
1 Scope(1)
2 References(1)
3 Terms and units of measurement(1)
4 Overview(2)
5 Measurement Requirements(2)
5.1 Labeling of energy efficiency (2)
5.2 Energy efficiency index (energy consumption) (3)
5.3 Energy efficiency class(3)
6 Detection conditions (3)
6.1 Environmental conditions (3)
6.2 Measuring equipment(4)
6.3 Gas for testing (5)
6.4 Test water(5)
6.5 Measurement uncertainty(6)
7 Test items and methods (6)
7.1 Sampling principles and methods (6)
7.2 Sample testing (6)
7.3 Original records(12)
7.4 Data processing (12)
8 Test Results(12)
8.1 Eligibility criteria for energy efficiency indicators (energy consumption) measurement and test results (12)
8.2 Evaluation criteria for test results (12)
8.3 Test report(13)
Appendix A Detection method (1) (14)
Appendix B Detection Method (2) (16)
Appendix C Detection Method (3) (17)
Appendix D Condensing Water Heater Efficiency and Condensing Boiler Low Water Temperature Test Efficiency Correction (19)
Appendix E Gas Requirements for Testing (21)
Appendix F Saturation vapor pressure (S) look-up table value (26)
Appendix G Evaluation of Uncertainty in Measurement of Energy Efficiency of Domestic Gas Instant Water Heaters and Gas Heated Water Heaters
example(28)
Appendix H Energy Efficiency Measurement and Testing Sampling Sheet for Household Gas Instant Water Heaters and Gas Heated Water Heaters
(Format) (41)
Appendix I Original Records of Energy Efficiency Measurement and Testing of Household Gas Instant Water Heaters and Gas Heating Water Heaters
(Format) (42)
Appendix J Energy Efficiency Measurement Report of Domestic Gas Instant Water Heater and Gas Heating Water Heater
(Format) (49)
Introduction
In order to standardize the energy efficiency of household gas instant water heaters and gas heating water heaters that implement energy efficiency label management
The measurement and inspection work is revised according to the requirements of JJF 1261.1-2017 "Measurement and Inspection Rules for Energy Efficiency of Energy-Using Products"
this specification.
This specification replaces JJF 1261.9-2013.Compared with JJF 1261.9-2013, except for editorial modifications, the main
The technical changes are as follows.
---The name of the specification is determined by the "Household Gas Instant Water Heater and Gas Heating Water Heater Energy Efficiency Marking Measurement Regulations"
"Regulations" was changed to "Rules for Measuring and Testing Energy Efficiency of Household Gas Instant Water Heaters and Gas Heating Water Heaters";
---The scope of application is from "household gas instant water heaters (including condensing water heaters) with heat load not greater than 70kW
and gas-fired heating and water heaters” to “household gas-fired household
Gas instant water heater (including condensing household gas instant water heater) and gas heating water heater (including condensing gas heating bath
Dual-purpose furnace" (see Chapter 1);
--- Added GB 25034-2010, CJ/T 336-2010, CJ/T 395-2012 three reference documents
(see Chapter 2);
--- Added "condensing domestic gas instant water heater", "condensing gas heating and bath dual-purpose furnace" and "rated
Heat load hot water efficiency", "Rated heat load heating efficiency" and "Energy efficiency grade" (see Chapter 3);
---In addition to the test method in accordance with the requirements of GB 6932-2001 "Household Gas Instant Water Heater", there are also
Added the relevant content of three documents according to GB 25034-2010, CJ/T 336-2010, and CJ/T 395-2012
conduct;
--- The minimum permissible energy efficiency index for each level in Table 1 is changed from the original fixed one for rated load and partial heat load
The single value of thermal efficiency is changed to define the lower limit of the larger value and the lower limit of the smaller value of these two thermal efficiency values;
--- Added Appendix D "Correction of Condensing Water Heater Efficiency and Condensing Furnace Low Water Temperature Test Efficiency".
The previous releases of this specification are as follows.
---JJF 1261.9-2013.
Household gas instant water heater and gas heating water heater
Energy Efficiency Measurement and Testing Rules
1 Scope
This specification stipulates the domestic gas instant hot water with a rated heat load not greater than 70kW that only uses gas as energy
Heaters (including condensing household gas instant water heaters, hereinafter referred to as "gas water heaters") and gas heating water heaters (including
Condensing gas heating and bath dual-purpose furnace, hereinafter referred to as "gas heating furnace") energy efficiency measurement requirements, measurement testing
Procedures, measurement and testing methods, evaluation criteria for measurement and testing results, and testing reports.
This specification is applicable to the supervision and testing of the energy efficiency measurement of gas water heaters and gas heating furnaces. Commissioned testing can refer to
This specification is carried out. Units that produce and sell gas water heaters and gas heating furnaces can also refer to this specification
detection.
This specification does not apply to gas volumetric water heaters.
The gas referred to in this specification shall comply with the provisions of GB/T 13611.
The gas water heaters and gas heating furnaces to be tested should be products that have passed the self-inspection by the producer, or the products purchased by the seller.
Export and sales of goods.
2 References
This specification references the following documents.
GB/T 2829-2002 Sampling procedure and table for periodic inspection counting (applicable to inspection of process stability)
GB 6932-2001 Household Gas Instant Water Heaters
GB/T 13611 Classification and basic characteristics of town gas
GB 20665-2015 Energy efficiency limit values and energy efficiency grades of domestic gas-fired instant water heaters and gas-fired heating water heaters
GB 25034-2010 Gas heating water heater
CJJ12-2013 Regulations for installation and acceptance of household gas burning appliances
CJ/T 336-2010 Condensing household gas instant water heater
CJ/T 395-2012 Condensing gas heating bath dual-purpose furnace
For dated references, only the dated version applies to this specification; for undated references
document, its latest version (including all amendments) applies to this specification.
3 Terminology and units of measurement
The following terms and definitions apply to this specification.
3.1 thermal efficiency
Effective utilization of heat as a percentage of the total heat released by complete combustion of gas.
3.2 Wobbenumber; Wobbeindex
The ratio of the calorific value of gas to the square root of its relative density, the unit of measurement is MJ/m3.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1261.9-2022_English be delivered?Answer: Upon your order, we will start to translate JJF 1261.9-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1261.9-2022_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1261.9-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1261.9-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1261.9-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|