HOME   Cart(3)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1245.5-2019 English PDF

US$509.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1245.5-2019: Program of Pattern Evaluation of Fixed AC Electricity Meters--Functional Requirements
Status: Valid

JJF 1245.5: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1245.5-2019English509 Add to Cart 5 days [Need to translate] Program of Pattern Evaluation of Fixed AC Electricity Meters--Functional Requirements Valid JJF 1245.5-2019
JJF 1245.5-2010English999 Add to Cart 5 days [Need to translate] Program of pattern evaluation of electricity meters. Particular requirements. Static meters for reative energy(Classes 2 and 3) Obsolete JJF 1245.5-2010

PDF similar to JJF 1245.5-2019


Standard similar to JJF 1245.5-2019

JJF 1234   JJF 1187   JJG 376   JJF 1245.2   JJF 1245.3   JJF 1245.1   

Basic data

Standard ID JJF 1245.5-2019 (JJF1245.5-2019)
Description (Translated English) Program of Pattern Evaluation of Fixed AC Electricity Meters--Functional Requirements
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Classification of International Standard 17.220
Word Count Estimation 22,240
Date of Issue 2019
Date of Implementation 2020-03-31
Issuing agency(ies) State Administration for Market Regulation

JJF 1245.5-2019: Program of Pattern Evaluation of Fixed AC Electricity Meters--Functional Requirements


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Fixed AC Electricity Meters--Functional Requirements National Measurement Technical Specification of the People's Republic of China Outline of Type Evaluation of Installed AC Energy Meter Functional requirements Published on December 31,.2019 2020-03-31 Implementation Issued by the State Administration of Market Supervision and Administration Type evaluation of installed AC electric energy meter Outline functional requirements Partial replacement JJF 1245.1 ~ 6-2010 Centralized unit. National Electromagnetic Measurement Technical Committee Main drafting unit. Zhejiang Institute of Metrology China Electric Power Research Institute Participated in the drafting unit. Zhejiang Zhengtai Instrument Co., Ltd. This specification entrusts the National Electromagnetic Measurement Technical Committee to interpret The main drafters of this specification. Jin Wenge (Zhejiang Institute of Metrology) Luo Ranran (China Electric Power Research Institute) Li Ming (Zhejiang Institute of Metrology) Participating drafters. Duan Xiaomeng (China Electric Power Research Institute) Chen Jing (Zhejiang Institute of Metrology) Feng Xueli (Zhejiang Zhengtai Instruments Co., Ltd.) Zhu Zhongwen (Zhejiang Institute of Metrology)

table of Contents

Introduction (Ⅲ) 1 Scope (1) 2 References (1) 3 Terminology (1) 4 Overview (2) 5 Legal management requirements (2) 6 Functional requirements (3) 6.1 Energy measurement and storage (3) 6.2 Maximum demand measurement (3) 6.3 Multiple rates (3) 6.4 Clock (4) 6.5 Fee Control (4) 6.6 Data communication (5) 6.7 Event records (5) 6.8 Clear (6) 6.9 Freeze (6) 6.10 Load record (6) 6.11 Harmonic energy measurement (6) 7 Type evaluation item table (7) 8 Technical documents and test prototypes to be submitted by the applicant (7) 9 Type evaluation conditions and methods (7) 9.1 General test conditions (7) 9.2 Energy measurement and storage (7) 9.3 Maximum demand measurement (7) 9.4 Multiple rates (8) 9.5 Clock (9) 9.6 Fee Control (9) 9.7 Data Communication (10) 9.8 Event Record (10) 9.9 Clear (10) 9.10 Freeze (10) 9.11 Load Record (11) 9.12 Harmonic energy measurement (11) 10 Type evaluation record format (11) Appendix A List of Test Items (12) Appendix B Document Information Format (13)

Introduction

"Type Evaluation Outline of Installed AC Watt-hour Meter" refers to international recommendations OIMLR46-1/-2..2012 and GB/T 17215 series of national standards, and in accordance with JJF 1016-2014 "Outline of Type Appraisal Outline of Measuring Instruments" Prepared by the requirements of "Guide to Writing." Contains the following 5 parts. --- JJF 1245.1-2019 "Installation type AC energy meter type evaluation outline active energy meter"; --- JJF 1245.2-2019 "Software Requirements for Type Evaluation Outline of Installed AC Energy Meter"; --- JJF 1245.3-2019 "Reactive Reactive Energy Meter for Type Evaluation Outline of Installed AC Energy Meter"; --- JJF 1245.4-2019 "Special Requirements and Safety Requirements for Type Evaluation Outline of Installed AC Energy Meters"; --- JJF 1245.5-2019 "Functional Requirements for Type Evaluation Outline of Installed AC Energy Meters" When using the "Type Evaluation Outline of Installed AC Watt-hour Meter" for the type evaluation test of the AC Watt-hour meter, the According to the characteristics of the energy meter, select the corresponding part of the outline. This series outline replaces the original series outline JJF 1245.1 ~ 6-2010, compared with JJF 1245.1 ~ 6-2010, The main changes are as follows. --- Adopt a new frame structure. no longer use general requirements-special requirements structure. With international recommendations OIML R46-1/-2..2012 is the main part, adding relevant content of GB/T 17215 series of national standards. JJF 1245.1-2019 And JJF 1245.2-2019 basically covers the content of OIMLR46-1/-2..2012; JJF 1245.3-2019 According to the content of reactive energy meter measurement and technical requirements in the national standard, it is compiled according to the architecture of JJF 1245.1-2019 Write; JJF 1245.4-2019 according to JJF 1245.1-2019 and JJF 1245.3-2019 not covered but national standards Contains the content preparation of measurement and technical requirements and safety-related requirements; JJF 1245.5-2019 in JJF Revised on the basis of 1245.6-2010. --- Added software requirements. JJF 1245.2-2019 refers to international recommendations OIMLR46-1/-2..2012 The content of the quantitative performance protection chapter, combined with the technical characteristics and management requirements of my country's electric energy meter, proposes software requirements for the electric energy meter Seeking, and give the verification method. --- Added and revised measurement and technical requirements. increased durability, higher harmonics, differential mode current interference, electricity Rapid changes in current, ringing wave and other items, modified voltage and current harmonics, constant magnetic field, radio frequency electromagnetic field radiation, electricity Pressure drop and short-term interruption, vibration, sunlight radiation protection, waterproof and other test items. The previous releases of this series of outlines are. JJF 1245.1-2010 "General Requirements for Type Evaluation Outline of Installed Energy Meter" JJF 1245.2-2010 "Specification Requirements for Type Evaluation Outline of Installed Watt-hour Meter" Electromechanical Active Watt-hour Meter (Level 0.5, 1 and 2) JJF 1245.3-2010 "Specification Requirements for Type Evaluation Outline of Installed Watt-hour Meter" Static Active Watt-hour Meter (0.2S, 0.5S, level 1 and 2)》 JJF 1245.4-2010 "Specification Requirements for Type Evaluation Outline of Installed Watt-hour Meter" Electromechanical Reactive Watt-hour Meter (Levels 2 and 3) JJF 1245.5-2010 "Specification Requirements for Type Evaluation Outline of Installed Watt-hour Meter" Static Reactive Watt-hour Meter (Levels 2 and 3) JJF 1245.6-2010 "Special Requirements for Installed Energy Meter Type Evaluation Outline Functional Energy Meter" Special instructions for this specification. This specification mainly refers to GB/T 17215.301-2007, GB/T 15284-2002 and GB/T 18460.3- The contents of.2001 and other standards were compiled, and the special requirements for the type evaluation outline of the installed energy meter Revised on the basis of Functional Energy Meter. Outline of Type Evaluation of Installed AC Energy Meter Functional requirements

1 Scope

This specification applies to single and three-phase active energy meters with a frequency of 50Hz or 60Hz (hereinafter referred to as instruments) Type evaluation of the functional requirements section. This specification does not apply to instruments whose nominal voltage exceeds 600V (multiphase instruments are line-to-neutral voltage) Instrument connected to electronic transformer (GB/T 20840.8-2007), used to connect low-voltage current sensor (IEC 61869-10..2017) The data interface of instrument, portable instrument, standard electric energy meter and instrument register.

2 Reference documents

This specification refers to the following documents. JJF 1245.1-2019 installation type AC energy meter type evaluation outline active energy meter JJF 1245.2-2019 Software Requirements for Type Evaluation Outline of Installed AC Energy Meter JJF 1245.3-2019 type-installed AC energy meter type evaluation outline reactive energy meter GB/T 15284-2002 Special requirements for multi-rate energy meters GB/T 17215.301-2007 Special requirements for multifunctional energy meters GB/T 17215.302-2013 Particular requirements for AC measurement equipment Part 2.Static harmonics Power meter GB/T 20840.8-2007 Transformers Part 8.Electronic current transformers IEC 61869-10..2017 Instrument transformers Part 10.Additional requirements for low-power passive current transformers (Instrumenttransformers-Part 10.Additionalrequirementsforlow-powerpassive currenttransformers) For dated reference documents, only the dated version applies to this specification; for those without date references The latest version (including all amendments) is applicable to this specification.

3 Terminology

The terms and definitions defined in JJF 1245.1-2019 and the following terms and definitions apply to this outline. 3.1 demand The average power within a specified time. 3.2 Demand cycle demandinterval Measure the average power in consecutive equal time intervals. 3.3 Maximum demand The maximum value of the demand recorded in the specified period or settlement period. 3.4 Interval demand blockintervaldemand Demand recorded during a period of demand with no overlapping periods.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1245.5-2019_English be delivered?

Answer: Upon your order, we will start to translate JJF 1245.5-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1245.5-2019_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1245.5-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1245.5-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1245.5-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.