US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1221-2009: Calibration Specification for Chassis Dynamometers for Automobile Emissions Testing Status: Valid JJF 1221: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1221-2009 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Chassis Dynamometers for Automobile Emissions Testing
| Valid |
JJF 1221-2009
|
JJF 1221-1990 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
O.T.N.of Temperature Secondary Primary Standard in the Range from 903.89 to 1337.58K
| Obsolete |
JJF 1221-1990
|
PDF similar to JJF 1221-2009
Basic data Standard ID | JJF 1221-2009 (JJF1221-2009) | Description (Translated English) | Calibration Specification for Chassis Dynamometers for Automobile Emissions Testing | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Classification of International Standard | 17.100 | Word Count Estimation | 19,178 | Date of Issue | 2009-07-10 | Date of Implementation | 2009-10-10 | Quoted Standard | GB 18285-2005; GB 3847-2005 | Regulation (derived from) | AQSIQ Announcement No. 78 of 2009 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard specifies the automobile exhaust emission testing on a chassis dynamometer (hereinafter referred to as the chassis dynamometer) of the metrological characteristics, calibration conditions, the calibration program and calibration methods. This standard applies to point tender engine car steady condition method, simple transient conditions and compression-ignition engine vehicles slow loading of exhaust emission testing on a chassis dynamometer calibration. |
JJF 1221-2009: Calibration Specification for Chassis Dynamometers for Automobile Emissions Testing ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Chassis Dynamometers for Automobile Emissions Testing
People's Republic of China National Metrology Technical Specifications
Automobile exhaust pollutant detection chassis
Dynamometer calibration specification
Posted 2009-07-10
2009-10-10 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Automobile exhaust pollutant detection chassis
Dynamometer calibration specification
This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on July 10, 2009, and from
From October 10, 2009 into effect.
Focal point. the National Technical Committee of Legal Metrology measurement management
Main drafting unit. Henan Institute of Metrology
Participated in the drafting. Zhejiang Jiangjiang Xing Automobile testing equipment factory
Zhejiang Institute of Metrology
Beijing Institute of Metrology detection
Shijiazhuang Huayan Transportation Technology Co., Ltd.
Foshan City, South China Instrument Co., Ltd.
This specification managed by the National Technical Committee of Legal Metrology measurement responsible for interpreting
The main drafters of this specification.
Liu Wei (Henan Institute of Metrology)
Zhu Weimin (Henan Institute of Metrology)
Zheng Li (Henan Institute of Metrology)
Drafters participate.
Zhoushen Sheng (Zhejiang Jiangjiang Xing Automobile testing equipment factory)
Jin Yan (Zhejiang Institute of Metrology)
Chen Xi (Beijing Institute of Metrology detection)
Chen Nanfeng (Shijiazhuang Huayan Transportation Technology Co., Ltd.)
Yang Yaoguang (Foshan City, South China Instrument Co., Ltd.)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Terms (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 roller apparatus (1)
Speed 5.2 (1)
Torque 5.3 (2)
5.4 Basic inertia (2)
5.5 Constant load loading coasting time (2)
5.6 Variable load loading coasting time (2)
5.7 Internal power loss (2)
5.8 load response time (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 Measurement Standard and calibration equipment (2)
7 calibration items and calibration methods (2)
7.1 calibration items (2)
7.2 Calibration method (3)
8 calibration results expression (9)
8.1 calibration certificate (9)
8.2 calibration measurement uncertainty (9)
9 Recalibration interval (9)
Appendix A calibration certificate (10)
Appendix B Uncertainty Analysis of Calibration Results (12)
Automobile exhaust pollutant detection chassis dynamometer calibration specification
1 Scope
This specification provides automobile exhaust pollutant detection chassis dynamometer (hereinafter referred to as the chassis dynamometer) special metering
Sex, calibration conditions, calibration items and calibration methods.
This instruction applies to vehicles equipped ignition engine method transient operating conditions, transient conditions law and simple compression-ignition engine vehicles
Loading condition reduction of exhaust emission detected by the chassis dynamometer calibration.
2 Citations
GB 18285-2005 ignition engine exhaust emission limits and measurement methods (two-speed idle and
BASM)
GB 3847-2005 vehicle measuring compression-ignition engines and compression-ignition engine vehicle exhaust and smoke emission limits
method
When using this specification it should be noted that using the currently valid version of the documents cited.
3 Terms
3.1 The basic chassis dynamometer inertia DIW (dynamometerinertiaweight)
Inertia simulation device simulation cars Zhongping moment of inertia of the equivalent quality of the car, called the equivalent inertia; and chassis
Equivalent inertia dynamometer all rotating parts equivalent called basic chassis dynamometer inertia.
3.2 main drum mainroler
And power absorption drum coaxial connector device.
4 Overview
Chassis dynamometer is used to simulate the vehicle when the vehicle exhaust emission condition was detected when the actual traveling road
Inertia and resistance of special measuring equipment.
Chassis dynamometer consists of the following components. means (PAU) and its controller, drum power absorption device,
Mechanical inertia, drive motor, synchronous devices, measuring devices, speed measuring device, lifting devices, the lateral spacing means
Is set, the display device and the like.
5 Metrological characteristics
5.1 roller apparatus
5.1.1 main drum diameter tolerance. ± 0.5%.
5.1.2 master cylinder surface radial runout of not more than 0.2%.
5.1.3 parallel bus around rollers not more than 1mm/m.
5.2 speed
Main drum line speed tolerance. ± 0.2km/h or ± 0.5%.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1221-2009_English be delivered?Answer: Upon your order, we will start to translate JJF 1221-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1221-2009_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1221-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1221-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1221-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|