JJF 1148-2006
Calibration Specification for Test Devices of Contact Lenses
National Metrology Technical Specification of the People's Republic
Contact lens detector calibration specification
Released on.2006-05-23
Implementation of.2006-08-23
The General Administration of Quality Supervision, Inspection and Quarantine issued
Contact lens detector calibration specification
ofContactLenses
This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on May 23,.2006, and
Implemented on August 23,.2006.
Focal Point. National Optical Metrology Technical Committee
Main drafting unit. China Institute of Metrology
Participated in the drafting unit. Chongqing Yuanshi Technology Co., Ltd.
This specification is interpreted by the National Optical Metrology Technical Committee.
The main drafters of this specification.
Zhang Jizhen (China Institute of Metrology)
Sun Jili (China Institute of Metrology)
Participate in the drafters.
Hu Bing (Chongqing Yuanshi Technology Co., Ltd.)
table of Contents
1 range (1)
2 Citations (1)
3 terms (1)
3.1 contact lens diameter (1)
3.2 radius of curvature of the optical zone after contact lens (1)
3.3 Contact lens center thickness (1)
3.4 contact lens detector (1)
4 Overview (1)
4.1 Use (1)
4.2 Measurement principle (1)
5 Measurement characteristics (2)
5.1 Diameter indication error (2)
5.2 After-optical area curvature radius indication error (3)
5.3 Center thickness indication error (3)
5.4 Rear optical zone curvature radius measurement repeatability (3)
6 Calibration conditions (3)
6.1 Environmental conditions (3)
6.2 Calibration Solution (3)
6.3 Calibration Standard (3)
7 Calibration items and calibration methods (3)
7.1 Preparation before calibration (3)
7.2 Diameter indication error (4)
7.3 Post-optical zone curvature radius indication error (4)
7.4 Rear optical zone curvature radius measurement repeatability (4)
7.5 Center thickness indication error (4)
8 calibration result expression (4)
9 re-interval time interval (5)
Appendix A Analysis of the Uncertainty of the Error of the Curvature Radius of the Contact Lens Detector (6)
Contact lens detector calibration specification
1 Scope
This specification applies to a variety of different principles, different categories dedicated to measuring soft hydrophilic contact lenses (below
The contact lens detector for the geometric parameters such as the diameter of the contact lens, the radius of curvature of the optical zone, and the thickness of the center.
quasi.
2 Citations
ISO /FDIS 18369-3.2005 "Ophthalmic optics - Contact lenses - Part 3. Methods of measurement" (Ophthal-
micoptics-Contactlenses-Part 3.Measurement meth-
Ods)
ISO 10344.1996 "Optical and optical instruments - Contact lenses - Contact lens test salt solutions" (Opticsand
opticalinstruments-Contactlenses-Salinesolutionforcontactlens
Testing)
JJF 1059-1999 "Measurement and Expression of Measurement Uncertainty"
Use of this specification should be done with the current valid version of the above cited documents.
3 terms
3.1 Contact lens diameter
The maximum size of the contact lens mirrored.
3.2 radius of curvature of the optical zone after contact lens
The radius of curvature of the central optical zone of the back surface of the contact lens.
3.3 Contact lens center thickness
The thickness of the contact lens at the geometric center.
3.4 contact lens detector
An instrument used to measure geometric parameters such as the diameter, radius of curvature, and center thickness of a contact lens.
Mirror detector (hereinafter referred to as contact lens detector).
4 Overview
4.1 Use
The contact lens detector is mainly used to measure the diameter of the contact lens, the radius of curvature of the optical zone after the contact lens, and the thickness of the contact lens center.
Some geometrical parameters, such as the device can also be used to quickly observe the surface quality and defects of the contact lens.