BASIC DATA
Standard ID JJF 1093-2002 (JJF1093-2002)
Description (Translated English) Calibration Specification for Projectors
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard N45;A60
Word Count Estimation 17,193
Date of Issue 2002-11-04
Date of Implementation 2003-05-04
Older Standard (superseded by this standard) JJG 108-1982
Quoted Standard JJF 1001-1998; JJF 1059-1999; JB/T 6380-1993
Drafting Organization Shaanxi Provincial Institute of Measurement Testing
Administrative Organization National Engineering geometric parameters measured Technical Committee
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to measuring vertical and horizontal projector (not including special-purpose projector) is calibrated.

JJF 1093-2002 Calibration Specification for Projectors National Metrology Technical Specification of the People's Republic Projector calibration specification Released on November 11,.2002 Implementation of.2003-05-04 The General Administration of Quality Supervision, Inspection and Quarantine issued Instead of JJG108-1982 This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on November 4,.2002, and It will take effect on May 4,.2003. Focal Point. National Geometric Quantity Engineering Measurement Technology Committee Main drafting unit. Shaanxi Institute of Metrology and Testing Participated in the drafting unit. Guangdong Institute of Metrology This specification is interpreted by the focal point The main drafters of this specification. Chang Qing (Shaanxi Institute of Metrology and Testing) Zhang Hui (Shaanxi Institute of Metrology and Testing) Zhang Lei (Shaanxi Institute of Metrology and Testing) Participate in the drafters. Liang Xiaoshi (Guangdong Institute of Metrology) table of Contents 1 range (1) 2 Citations (1) 3 Overview (1) 4 Measurement characteristics (2) 4.1 Straightness of the vertical and horizontal (downward) movement of the table to the guide rail (2) 4.2 The verticality of the vertical and horizontal (vertical) movement of the table to the guide rail (2) 4.3 Correctness of the reading device (2) 4.4 Digital display stability (3) 4.5 Instrument indication error (3) 4.6 Projection objective optical axis and the vertical axis of the projected illumination optical axis and the work surface (3) 4.7 Correctness of Projector Magnification (3) 4.8 Parallelism of the horizontal line of the screen crosshair to the direction of movement of the longitudinal rail (3) 4.9 Indication error of rotary screen (or rotary table) (3) 4.10 Correctness of the thimble (3) 5 Calibration conditions (3) 5.1 Environmental conditions (3) 5.2 Standards and other equipment for calibration (3) 6 Calibration items and calibration methods (4) 6.1 Straightness of the vertical and horizontal (vertical) movement of the table (4) 6.2 The verticality of the vertical and horizontal (vertical) movement of the table (4) 6.3 Correctness of the reading device (5) 6.4 Numerical display stability (5) 6.5 Instrument indication error (6) 6.6 Projection objective axis and projection illumination axis perpendicular to the work surface (6) 6.7 Correction of projector magnification (6) 6.8 Parallelism of the horizontal line of the screen crosshair to the direction of movement of the longitudinal rail (7) 6.9 Indication error of rotary screen (or rotary table) (7) 6.10 Correctness of the thimble (8) 7 Expression of calibration results (8) 8 re-study interval (8) Appendix A Contents of the Calibration Certificate (9) Appendix B Evaluation of Measurement Uncertainty of Projector Indication Error (10) Projector calibration specification 1 Scope This specification applies to the calibration of vertical and horizontal projectors (excluding special purpose projectors). 2 Citations This specification refers to the following documents. JJF 1001-1998 General measurement terms and definitions JJF 1059-1999 Measurement Uncertainty Evaluation and Representation JB/T 6380-1993 projector Use of this specification should be done with the current valid version of the above cited documents. 3 Overview The projector is an optical mechanical metering instrument. The main structure is divided into vertical projectors (the optical axis of the objective lens is perpendicular to the work As a countertop, the structure is shown in Figure 1) and the horizontal projector (the objective optical axis is parallel to the work surface, the structure is shown in the figure) 2), its working principle is shown in Figure 3. The light beam emitted from the light source passes through the condensing mirror and becomes parallel light to illuminate the object to be measured. Then, through the objective lens, the image is projected onto the screen, and the workpiece is subjected to contour measurement or coordinate measurement. Figure 1 Vertical projector Figure 2 Horizontal projector The projector's workbench is divided into a simple type (the workbench has no reading device) and a light type (the workbench's stroke is less than, etc.) It is available in 150mm × 75mm) and heavy duty (the stroke of the table is more than 150mm × 75mm). Projector according to the screen ...