Powered by Google-Search & Google-Books www.ChineseStandard.net Database: 169760 (Oct 16, 2021)
HOME   Quotation   Tax   Examples Standard-List   Contact-Us   Cart
  

JJF 1064-2010

JJF 1064-2010_English: PDF (JJF1064-2010)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)Related StandardStatusGoogle Book
JJF 1064-2010English809 Add to Cart Days<=6 Calibration specification for coordinate measuring machine JJF 1064-2010 Valid JJF 1064-2010
 

BASIC DATA
Standard ID JJF 1064-2010 (JJF1064-2010)
Description (Translated English) Calibration specification for coordinate measuring machine
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.040
Word Count Estimation 35,351
Date of Issue 2010-09-06
Date of Implementation 2011-03-06
Older Standard (superseded by this standard) JJF 1064-2004
Quoted Standard GB/T 16857.1-2002; GB/T 16857.2-2006; ISO 10360-3-2000; GB/T 16857.4-2003; GB/T 16857.5-2004; VDI/VDE 2617 PART 6.1; ISO/TS 23165-2006; GB/T 18779.1; JJF 1130-2003; JJF 1001-1998; JJF 1059-1999; JJF 1094-2002
Drafting Organization China Institute of Metrology
Administrative Organization National Technical Committee geometric length measurement
Regulation (derived from) ?AQSIQ Announcement 2010 No.100
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the three-dimensional coordinates of the side volume machine calibration Cartesian coordinate system. Refer to perform acceptance inspection side. The actual amount of machine configuration differences coordinate large side, you need to select the most relevant characteristics of the actual situation into account when calibrating.

JJF 1064-2010
Calibration specification for coordinate measuring machine
People's Republic of China National Metrology Technical Specifications
Coordinate measuring machine calibration specification
Issued on. 2010-09-06
2011-03-06 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Coordinate measuring machine calibration specification
Machine
Replacing JJF 1064-2004
This specification by the State Administration of Quality Supervision, Inspection and Quarantine September 6, 2010 approval, and since 2011
From March 6 implementation.
Focal point. the National Technical Committee of length measuring geometry
Drafting units. China Institute of Metrology
Guangdong Provincial Institute of Metrology
Suzhou days-Precision Technology Co., Ltd.
This specification shall be interpreted by the focal point
Drafters of this specification.
Wang farming (China Institute of Metrology)
Pei Limei (China Institute of Metrology)
Zhang Yong (Guangdong Institute of Metrology)
Any state (China Institute of Metrology)
Xu Yihua (Suzhou days-Precision Technology Co., Ltd.)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Terms and definitions (2)
4 Overview (4)
5 Metrological characteristics (4)
5.1 Error detection (4)
5.2 size measurement indication error (E) (5)
5.3 Imaging probe size measurement error (EV) (5)
5.4 axis error (5)
5.5 scanning probing error (THP) (5)
Over 5.6 probing system error (5)
6 calibration conditions (5)
Environmental conditions 6.1 (5)
6.2 probe system configuration (5)
Operation conditions 6.3 (5)
6.4 Standard (6)
7 calibration items and calibration methods (7)
7.1 Error detection (7)
7.2 size measurement error (10)
7.3 axis error (11)
7.4 scanning probing error (14)
Over 7.5 probing system error (15)
For 8 calibration results (19)
8.1 calibration certificate (19)
8.2 Compliance Assessment (19)
9 Recalibration interval (20)
Appendix Verification (informative) (21) A period
Appendix B large supplementary measure the coordinate measuring machine (22)
Appendix C Example of measurement uncertainty (23)
Appendix D calibration certificate page format (29)
Coordinate measuring machine calibration specification
1 Scope
This specification applies to three-dimensional coordinate measuring machine calibration Cartesian coordinate system. Acceptance testing can be implemented by reference.
The actual configuration of the coordinate measuring machine big difference, you need to select the relevant metrological characteristics according to the actual situation at calibration.
2 Citations
For dated reference documents, all subsequent amendments (not including errata content) or revisions do not
Applicable to this specification, but according to the specification of the parties to an agreement can negotiate whether to use the latest versions of these documents.
For undated reference documents, the latest versions apply to this document.
GB/T 16857.1-2002 Geometrical Product Specifications (GPS) - Acceptance coordinate measuring machines and complex
Round testing - Part 1. Vocabulary
GB/T 16857.2-2006 Geometrical product specifications (GPS) coordinate measuring machine acceptance and reverification
Testing - Part 2. Measurements for coordinate measuring machines
ISO 10360-3.2000 Geometrical Product Specifications (GPS) coordinate measuring machine acceptance and reverification
Testing - Part 3. axis rotary table as the fourth axis coordinate measuring machine (GeometricalProductSpeci-
fications (GPS) -Acceptanceandreverificationtestsforcoordinatemeasuringmachines
(CMM) -Part 3. CMMswiththeaxisofarotarytableasthefourthaxis)
GB/T 16857.4-2003 Geometrical Product Specifications (GPS) - Acceptance coordinate measuring machines and complex
Unit testing - Part 4. In the scan mode using a coordinate measuring machine
GB/T 16857.5-2004 Geometrical Product Specifications (GPS) - Acceptance coordinate measuring machines and complex
Unit testing - Part 5. Using multiple probing syste