JG/T 162: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JG/T 162-2017 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Remote transmission meter reading system for civil building
| Valid |
JG/T 162-2017
|
| JG/T 162-2009 | English | 959 |
Add to Cart
|
5 days [Need to translate]
|
Remote transmission meter reading system for residence
| Obsolete |
JG/T 162-2009
|
| JG/T 162-2004 | English | 799 |
Add to Cart
|
5 days [Need to translate]
|
Long-range transmission meter reading system for residence - Special line transmission for data
| Obsolete |
JG/T 162-2004
|
PDF similar to JG/T 162-2017
Basic data | Standard ID | JG/T 162-2017 (JG/T162-2017) | | Description (Translated English) | Remote transmission meter reading system for civil building | | Sector / Industry | Building & Construction Industry Standard (Recommended) | | Classification of Chinese Standard | N22 | | Classification of International Standard | 17.220.20 | | Word Count Estimation | 178,139 | | Date of Issue | 2017-09-30 | | Date of Implementation | 2018-05-01 | | Older Standard (superseded by this standard) | JG/T 162-2009 | | Regulation (derived from) | Housing and Urban-Rural Development Bulletin 2017 No. 1688 | | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China |
JG/T 162-2017: Remote transmission meter reading system for civil building---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Far away civil meter reading system)
ICS 17.220.20
N22
People's Republic of China Construction Industry Standard
Replace JG/T 162-2009
Civil building remote meter reading system
Released on.2017-09-30
2018-05-01 implementation
Ministry of Housing and Urban-Rural Development
Content
Foreword I
1 Scope 1
2 Normative references 1
3 Terms and Definitions 2
4 General requirements 5
5 Requirements 9
6 Test method 16
7 Inspection rules 23
8 Marking, packaging, transport and storage 25
9 Instructions for use preparation requirements 26
Appendix A (Normative Appendix) Remote Reading Meter Reading System Accuracy Formula 27
Appendix B (Normative Appendix) Remote Communication Protocol between Master Station and Acquisition Terminal 29
Appendix C (Normative) Data Format Description 154
Appendix D (Normative) Event Code ERC 167
Appendix E (Normative) Data Freezing Density 168
Appendix F (Normative) Error Denied Code ERR 169
Appendix G (Normative) SMS (SMS) transmission interface split 170
Appendix H (Normative) Unit Code Table 172
Appendix I (Normative Appendix) Port Number, User Major Class Number, User Small Class Number 173
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is a revision of JG/T 162-2009 "Residential Remote Meter Reading System". This standard is compared with JG/T 162-2009.
The changes are as follows.
--- Revised the scope of the standard (see Chapter 1, see Chapter 1 of the.2009 edition);
--- Revised the canonical reference document (see Chapter 2, see Chapter 2 of the.2009 edition);
---Modified the definition of data private line transmission, data low-voltage power line carrier transmission, data network transmission, data wireless transmission (see
3.1.1, 3.1.2, 3.1.3 and 3.2, see 3.1.1, 3.1.2, 3.1.3 and 3.2) of the.2009 edition;
---Modified definitions of base tables, remote transmission tables, pulse remote transmission tables, direct reading remote transmission tables, accuracy, collectors, concentrators, master stations and channels (see
3.3, 3.4, 3.4.1, 3.4.2, 3.5, 3.6, 3.7, 3.8, 3.9, 3.9.1 and 3.9.2, see 3.3, 3.4, 3.5, 3.6, 3.7 of the.2009 edition.
3.8, 3.9, 3.10, 3.11);
--- Revised the definition of remote meter reading system, one copy reading success rate, data reading total error rate, and pulse constant (see 3.10, 3.11)
3.13 and 3.14, see 3.12, 3.13, 3.14 and 3.15 for the.2009 edition);
--- Increased the definition of daily reading success rate, acquisition terminal, physical quantity sensor (see 3.12, 3.15 and 3.16);
--- Added terminal address, system broadcast address, terminal group address, master station address, measurement point, data unit identifier, information point, information
Class, task, start station, slave station, communication flow, level 1 data, level 2 data definition (see 3.17, 3.18, 3.19, 3.20, 3.21)
3.22, 3.23, 3.24, 3.25, 3.26, 3.27, 3.28, 3.29 and 3.30);
--- Removed the requirements of the base table and the requirements of the remote table (see 5.1.1 and 5.1.2 of the.2009 version);
---Modified the data transmission accuracy of the pulse remote transmission table and the data transmission accuracy of the direct reading remote transmission table (see 5.1.1 and 5.1.2, see
5.3.5 of the.2009 edition);
--- Increased overall requirements (see Chapter 4);
--- Increased remote meter power supply, continuous power supply stability, power supply (see 5.1.3, 5.3.6, 5.3.8);
---Modified the requirements of the main station and the enclosure protection (see 5.2, 5.3.9, see 5.2, 5.3.3.7 of the.2009 edition);
---Modified the functions, appearance, environmental adaptability, electromagnetic compatibility and power consumption required by the collector and concentrator (see 5.3.1, 5.3.2
5.3.3, 5.3.4 and 5.3.5, see 5.3.1, 5.3.2, 5.3.3, 5.3.4 and 5.3.6) of the.2009 edition;
---Modified the functions required by the system, system reading accuracy, one copying success rate and data reading total error rate (see
5.4.1, 5.4.2, 5.4.3.1 and 5.4.4, see 5.4.1, 5.4.2, 5.4.3 and 5.4.4 of the.2009 edition;
--- Increased the daily reading success rate requirement (see 5.4.3.2);
--- Removed system reliability requirements and transmission distance requirements (see 5.4.5 and 5.4.6 for.2009);
---Modified security requirements (see 5.5 and 5.3.7, see version 5.5 of.2009);
--- Modified the signal band (band), test environmental conditions (see 5.6, 6.1, see 5.6, 6.1 of the.2009 version);
--- Deleted the test of the table, the test of the main station (see 6.2, 6.3 of the.2009 version);
--- Modified the remote transmission table data transmission accuracy test (see 6.2, see version 6.4.5 of the.2009 version);
---Modified the function test, visual inspection, environmental adaptability test, electromagnetic compatibility test, power consumption test in the collector and concentrator test
(see 6.3.1, 6.3.2, 6.3.3, 6.3.4 and 6.3.5, see 6.4.1, 6.4.2, 6.4.3, 6.4.4 and 6.4.6 of the.2009 edition);
--- Increased continuous power stability test, power supply impact test (see 6.3.6, 6.3.8);
---Modified electrical safety test, shell protection test (see 6.3.7, 6.3.9, see 6.7.1, 6.4.3.7 of.2009 edition);
---Modified system test, safety test (see 6.4, 6.5, see 6.5, 6.6 of.2009 edition);
--- Increased the general provisions of the inspection rules (see 7.1);
--- Revised inspection classification, final inspection and periodic inspection, factory inspection (see Chapter 7, see Chapter 7 of the.2009 edition);
--- Modified the logo, packaging, transportation, storage and instructions for use (see Chapter 8, Chapter 9, see Chapters 8, 9 of the.2009 edition);
--- Modified Appendix A, deleted Appendix B and Appendix C (see Appendix A, see Appendix A, Appendix B and Appendix C of the.2009 edition);
--- Added Appendix B (normative appendix) remote communication protocol between the primary station and the collection terminal;
--- Added Appendix C (normative appendix) data format description;
--- Added Appendix D (normative appendix) event code ERC;
--- Increased the data freeze density of Appendix E (normative appendix);
--- Added Appendix F (normative appendix) error denial code ERR;
--- Added Appendix G (normative appendix) SMS (SMS) transmission interface split;
--- Added Appendix H (normative appendix) unit code table;
--- Added Appendix I (normative appendix) port number, user major class number and user minor class number.
This standard was proposed by the Institute of Standardization of the Ministry of Housing and Urban-Rural Development.
This standard is under the jurisdiction of the Information Technology Application Standardization Technical Committee of the Ministry of Housing and Urban-Rural Development.
This standard is drafted by. Policy Research Center of Ministry of Housing and Urban-Rural Development, Beijing University of Chemical Technology, Beijing Zhengneng Yuanchuan Energy-saving Technology Research
Research Institute Co., Ltd.
Participated in the drafting of this standard. Ningbo Donghai Group Co., Ltd., Shenzhen Huaxu Technology Development Co., Ltd., Chengdu Qianjia Technology Co., Ltd.
Company, Ningbo Samsung Medical Electric Co., Ltd., Jinka Intelligent Group Co., Ltd., Jining Lanwei Intelligent Gas Meter Co., Ltd., Zhejiang
Jiang Cangnan Instrument Group Dongxing Intelligent Instrument Co., Ltd., Zhengzhou Enron Measurement and Control Technology Co., Ltd., Qingdao Jicheng Electronics Co., Ltd., China
National Electric Power Research Institute, China Eco-city Research Institute Co., Ltd. Smart Water Center, Hebei Yugao Power Equipment Development Co., Ltd., smoke
Taiwan Oriental Weston Electric Co., Ltd., Nanjing Rixin Technology Co., Ltd., Nanjing Feiteng Electronic Technology Co., Ltd., Titanium Technology Co., Ltd.
Company, Liaoning Aerospace Star IOT Instrument Technology Co., Ltd., Ningbo Canaan Intelligent Electric Co., Ltd., Zhejiang Wansheng Intelligent Technology Co., Ltd.
Company, Ningbo Danang Instrument Co., Ltd., Beijing Jingyuan Water Instrument Co., Ltd., Hangzhou Xili Intelligent Technology Co., Ltd., Boer
(Wuxi) Power Complete Set Co., Ltd., Xintian Technology Co., Ltd., Ningbo Jingcheng Technology Co., Ltd., Beijing Huada Zhibao Electronics
System Co., Ltd., Sichuan Haili Intelligent Technology Co., Ltd., Jinan Pushai Communication Technology Co., Ltd., Yantai Aerospace Drew Energy Saving Technology
Co., Ltd., Ningbo Water Meter Co., Ltd., Chongqing Smart Water Meter Group Co., Ltd., Chengdu Qinchuan Technology Development Co., Ltd., Beijing Fangsheng
Youcheng Technology Co., Ltd., Beijing Huanglong Century Technology Co., Ltd., Beijing Hailin Energy Saving Equipment Co., Ltd., Beijing Jebsen Century
Technology Co., Ltd., Chongqing Century Light Technology Industrial Co., Ltd., Jiangyin Zhonghe Power Meter Co., Ltd., Shenzhen Jinzhengfang Technology
Co., Ltd., Shenzhen Youxunda Technology Co., Ltd., Yangzhou Yiyang Electronic Technology Co., Ltd., Shenzhen Jiexian Digital Technology Co., Ltd.
Co., Ltd., Hangzhou Shenyi Technology Co., Ltd., Zhangzhou Keneng Electric Co., Ltd., Hunan Weiming Energy Technology Co., Ltd., Shenzhou Think Tank
Big Data Technology Co., Ltd., Shandong Yuwei Technology Co., Ltd., Jilin Province Construction Standardization Management Office, Henan Province Architectural Design Research
Research Institute Co., Ltd., Shaanxi Provincial Building Standard Design Office, Yantai Del Automatic Control Technology Co., Ltd., Xi'an Qiqi Electronics Co., Ltd.
Shanghai Dihong Communication Technology Co., Ltd., Wuxi Juwei Technology Co., Ltd., Harbin Shengchang Technology Development Co., Ltd., Yangzhou Wantai Electronics Division
Technology Co., Ltd., Jiayi Technology Co., Ltd.
The main drafters of this standard. Lin Runquan, Wang Xuewei, Wan Jing, Yu Shusen, Wang Yueren, Shang Xingtai, Zheng Dejia, Yan Lihua, Sun Fuqiang, Chai Jie,
Li Xuezhi, Zhu Ermao, Liu Delin, Liu Xuan, Gao Xueqing, Zhang Junhu, Cheng Bo, Long Xianglin, Shen Zhenyu, Ma Ying, Yu Jianlong, Yuan Jing, Chen Yong, Zhao Yong,
Yuan Zhimin, Zhang Enman, Jin Wensheng, Zhang Shanliang, Zhang Wenge, Zhang Wenxin, Xing Weihua, Li Jinhua, Wang Wenjin, Yang Xing, Cha Saibin, Fei Zhanbo, Shen Anbang,
Zhang Yifan, Tan Wanqiang, Wang Dongchang, Wei Dong, Chen Dongyan, Jiang Xiaojie, Chen Fuguang, Wei Qinghua, Quan Yaqiang, Wang Baohua, Zhou Dongmei, Qian Zhifeng, Yang Liuyin,
Wang Yahui, Fei Honghai, Fan Jun, Hua Siyang, Shu Jiehong, Bian Xuetao, Chen Jian, Chen Rushen, Li Yongyue, Li Lin, Zhu Zhengjian, Pan Ke, Liang Xiaonong, Gong Shangyan,
Li Yumei, Zhang Huabing, Guo Yonglin, Yuan Liulu, Li Weifeng, Jiang Yanxia, Zhao Guoguang, Lin Xi, Guo Honglei, Lu Man, Zhang Xianli, Lin Dong, Cui Chongmin,
Pan Jianhua, Shi Yinmao.
The previous versions of the standards replaced by this standard are.
---JG/T 162-2004;
---JG/T 162-2009.
Civil building remote meter reading system
1 Scope
This standard stipulates the general requirements, requirements, test methods, inspection rules, and remote inspection system for civil buildings (referred to as remote meter reading system).
Logo and instructions for use, packaging, transportation and storage.
This standard applies to the data collection and transmission of water, electricity, gas, heat and other instruments and sensors for civil buildings (residential buildings and public buildings).
System requirements.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 191 packaging storage and transportation icon
GB/T 1988 Seven-digit coded character set for information technology information exchange
GB/T 2260-2007 Administrative division code of the People's Republic of China
GB/T 2423.1 Environmental testing of electrical and electronic products - Part 2. Test methods Test A. Low temperature
GB/T 2423.2 Environmental testing of electric and electronic products - Part 2. Test method Test B. High temperature
GB/T 2423.9 Environmental testing of electrical and electronic products - Part 2. Test methods Test Cb. Constant moist heat for equipment
GB/T 2423.21-2008 Environmental testing of electric and electronic products - Part 2. Test method Test M. Low pressure
GB/T 2829-2002 Periodic inspection count sampling procedures and tables (applicable to the inspection of process stability)
GB/T 4208-2017 enclosure protection grade (IP code)
GB 4943.1-2011 Safety of information technology equipment - Part 1. General requirements
GB/T 6107-2000 Interface between data terminal equipment and data circuit terminating equipment using serial binary data exchange
GB/T 9813.1 General specification for computers - Part 1. Desktop microcomputer
GB/T 9969 General guidelines for the use of industrial products
General technical conditions for GB/T 13384 mechanical and electrical product packaging
GB 15629.11 (all parts) Telecommunications and information exchange between information technology systems - Particular requirements for local area networks and metropolitan area networks
Part 11. Wireless LAN Media Access Control and Physical Layer Specifications
GB/T 17626.2-2006 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test
GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test
GB/T 17626.4-2008 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test
GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test
GB/T 17626.6-2017 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of RF field induction
GB/T 17626.8-2006 Electromagnetic compatibility test and measurement technology Power frequency magnetic field immunity test
GB/T 17626.11-2008 Electromagnetic compatibility test and measurement techniques Immunity to voltage dips, short interruptions and voltage changes
test
GB/T 18657.1-2002 Telecontrol equipment and systems - Part 5. Transport clauses
Telecontrol equipment and systems - Part 5. Transmission protocol, Part 3. General structure of application data.
GB/T 22239-2008 Information security technology information system security level protection basic requirements
|