US$479.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. HYT100-2007: Test method of seawater turbidity analyzer Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| HY/T 100-2007 | English | 479 |
Add to Cart
|
3 days [Need to translate]
|
Test method of seawater turbidity analyzer
| Valid |
HY/T 100-2007
|
Standard similar to HYT100-2007 HY/T 0357 HY/T 0333 HY/T 092
Basic data | Standard ID | HY/T 100-2007 (HY/T100-2007) | | Description (Translated English) | Test method of seawater turbidity analyzer | | Sector / Industry | Marine Industry Standard (Recommended) | | Classification of Chinese Standard | N92 | | Classification of International Standard | 7.06 | | Word Count Estimation | 15,119 | | Date of Issue | 12/19/2007 | | Date of Implementation | 1/1/2008 | | Issuing agency(ies) | State Oceanic Administration | | Summary | This standard specifies the seawater turbidity meter test items, test equipment, testing environmental conditions, the detection method to detect and report writing requirements. This standard applies to the detection of turbidity meter long underwater use. |
HYT100-2007: Test method of seawater turbidity analyzer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method of seawater turbidity analyzer
ICS 07.060
N92
People's Republic of China Marine Industry Standard
HY/T 100-2007
Testing method of seawater turbidity meter
2007-12-19 released
Implementation of.2008-01-01
Issued by the State Oceanic Administration
Foreword
Appendix A in this standard is a normative appendix, and Appendix B, Appendix C, and Appendix D are informative appendices.
This standard was proposed by the National Oceanic Standards and Metrology Center.
This standard is under the jurisdiction of the National Marine Standardization Technical Committee (SAC/TC283).
Drafting organization of this standard. National Marine Standard Metrology Center.
The main drafters of this standard. Wang Aijun, Wang Cong, Gao Zhanke, Sui Jun, Li Mingzhao.
HY/T 100-2007
Testing method of seawater turbidity meter
1 scope
This standard specifies the testing items, testing equipment, testing environmental conditions and testing methods of seawater turbidity measuring instruments (hereinafter referred to as turbidity meters)
And the requirements for the preparation of test reports.
This standard is applicable to the detection of turbidity meters that have been used for a long time under water.
2 Normative references
The clauses in the following documents become clauses of this standard after being quoted. For dated reference documents, all subsequent
Amendments (not including errata content) or revisions do not apply to this standard. However, all parties that have reached an agreement based on this standard are encouraged to study
Is the latest version of these files available? For undated references, the latest version is applicable to this standard.
HY 016.2 Basic environmental test methods for marine instruments Low temperature test
HY 016.3 Basic environmental test methods for marine instruments Low temperature storage test
HY 016.4 Basic environmental test methods for marine instruments, high temperature test
HY 016.5 Basic environmental test methods for marine instruments, high temperature storage test
HY 016.8 Basic environmental test methods for marine instruments Alternating damp heat test
HY 016.11 Basic environmental test methods for marine instruments Vibration test
HY 016.12 Basic environmental test methods for marine instruments Impact test
HY 016.13 Basic environmental test method for marine instruments Continuous impact test
HY 016.14 Basic environmental test methods for marine instruments Tilt and roll test
HY 016.15 Basic environmental test methods for marine instruments Hydrostatic pressure test
3 Terms and definitions
The following terms and definitions apply to this standard.
3.1
Using zero turbidity water as the sample for continuous testing, the turbidity meter shows the value that changes within a certain period of time.
Note. Rewrite the standard HY/T 08-1992 and define 01-035.
3.2
An instrument that uses light scattering to measure the concentration of suspended solids in seawater.
Note. Rewrite the standard HY/T 08-1992 and define 03-042.
4 Technical requirements
4.1 Appearance
The appearance requirements of the turbidity meter are as follows.
a) The shell and surface of the turbidity meter should be uniform in color, smooth and firm, with no obvious scratches, corrosion, bottom leakage, or cracks.
Streaks and blisters;
b) The electrode lead of the turbidity meter should be connected reliably, and the fasteners and connectors should not be loose.
HY/T 100-2007
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of HYT100-2007_English be delivered?Answer: Upon your order, we will start to translate HYT100-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of HYT100-2007_English with my colleagues?Answer: Yes. The purchased PDF of HYT100-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|