HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

HYT100-2007 English PDF

US$479.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
HYT100-2007: Test method of seawater turbidity analyzer
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
HY/T 100-2007English479 Add to Cart 3 days [Need to translate] Test method of seawater turbidity analyzer Valid HY/T 100-2007

Standard similar to HYT100-2007

HY/T 0357   HY/T 0333   HY/T 092   

Basic data

Standard ID HY/T 100-2007 (HY/T100-2007)
Description (Translated English) Test method of seawater turbidity analyzer
Sector / Industry Marine Industry Standard (Recommended)
Classification of Chinese Standard N92
Classification of International Standard 7.06
Word Count Estimation 15,119
Date of Issue 12/19/2007
Date of Implementation 1/1/2008
Issuing agency(ies) State Oceanic Administration
Summary This standard specifies the seawater turbidity meter test items, test equipment, testing environmental conditions, the detection method to detect and report writing requirements. This standard applies to the detection of turbidity meter long underwater use.

HYT100-2007: Test method of seawater turbidity analyzer

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method of seawater turbidity analyzer ICS 07.060 N92 People's Republic of China Marine Industry Standard HY/T 100-2007 Testing method of seawater turbidity meter 2007-12-19 released Implementation of.2008-01-01 Issued by the State Oceanic Administration

Foreword

Appendix A in this standard is a normative appendix, and Appendix B, Appendix C, and Appendix D are informative appendices. This standard was proposed by the National Oceanic Standards and Metrology Center. This standard is under the jurisdiction of the National Marine Standardization Technical Committee (SAC/TC283). Drafting organization of this standard. National Marine Standard Metrology Center. The main drafters of this standard. Wang Aijun, Wang Cong, Gao Zhanke, Sui Jun, Li Mingzhao. HY/T 100-2007 Testing method of seawater turbidity meter

1 scope

This standard specifies the testing items, testing equipment, testing environmental conditions and testing methods of seawater turbidity measuring instruments (hereinafter referred to as turbidity meters) And the requirements for the preparation of test reports. This standard is applicable to the detection of turbidity meters that have been used for a long time under water.

2 Normative references

The clauses in the following documents become clauses of this standard after being quoted. For dated reference documents, all subsequent Amendments (not including errata content) or revisions do not apply to this standard. However, all parties that have reached an agreement based on this standard are encouraged to study Is the latest version of these files available? For undated references, the latest version is applicable to this standard. HY 016.2 Basic environmental test methods for marine instruments Low temperature test HY 016.3 Basic environmental test methods for marine instruments Low temperature storage test HY 016.4 Basic environmental test methods for marine instruments, high temperature test HY 016.5 Basic environmental test methods for marine instruments, high temperature storage test HY 016.8 Basic environmental test methods for marine instruments Alternating damp heat test HY 016.11 Basic environmental test methods for marine instruments Vibration test HY 016.12 Basic environmental test methods for marine instruments Impact test HY 016.13 Basic environmental test method for marine instruments Continuous impact test HY 016.14 Basic environmental test methods for marine instruments Tilt and roll test HY 016.15 Basic environmental test methods for marine instruments Hydrostatic pressure test

3 Terms and definitions

The following terms and definitions apply to this standard. 3.1 Using zero turbidity water as the sample for continuous testing, the turbidity meter shows the value that changes within a certain period of time. Note. Rewrite the standard HY/T 08-1992 and define 01-035. 3.2 An instrument that uses light scattering to measure the concentration of suspended solids in seawater. Note. Rewrite the standard HY/T 08-1992 and define 03-042.

4 Technical requirements

4.1 Appearance The appearance requirements of the turbidity meter are as follows. a) The shell and surface of the turbidity meter should be uniform in color, smooth and firm, with no obvious scratches, corrosion, bottom leakage, or cracks. Streaks and blisters; b) The electrode lead of the turbidity meter should be connected reliably, and the fasteners and connectors should not be loose. HY/T 100-2007

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of HYT100-2007_English be delivered?

Answer: Upon your order, we will start to translate HYT100-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of HYT100-2007_English with my colleagues?

Answer: Yes. The purchased PDF of HYT100-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.