US$219.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. HJ 1247-2022: Self-monitoring technology guidelines for pollution sources - Coal processing-production of synthesis gas and liquid fuel Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| HJ 1247-2022 | English | 219 |
Add to Cart
|
3 days [Need to translate]
|
Self-monitoring technology guidelines for pollution sources - Coal processing-production of synthesis gas and liquid fuel
| Valid |
HJ 1247-2022
|
Standard similar to HJ 1247-2022 HJ 1347.1 HJ 1347.2 HJ 1346.1
Basic data | Standard ID | HJ 1247-2022 (HJ1247-2022) | | Description (Translated English) | Self-monitoring technology guidelines for pollution sources - Coal processing-production of synthesis gas and liquid fuel | | Sector / Industry | Environmental Protection Industry Standard | | Word Count Estimation | 9,989 | | Issuing agency(ies) | Ministry of Ecology and Environment |
HJ 1247-2022: Self-monitoring technology guidelines for pollution sources - Coal processing-production of synthesis gas and liquid fuel ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Self-monitoring technology guidelines for pollution sources - Coal processing-production of synthesis gas and liquid fuel
National Ecological Environment Standard of the People's Republic of China
Technical guide for self-monitoring of pollutant discharge units
Coal Processing - Syngas and Liquid Fuel Production
Self-monitoring technology guidelines for pollution sources
-Coal processing-production of synthesis gas and liquid fuel
Published on 2022-04-27
2022-07-01 Implementation
Released by the Ministry of Ecology and Environment
directory
Foreword...ii
1 Scope...1
2 Normative references...1
3 Terms and Definitions...2
4 General requirements for self-monitoring...2
5 Monitoring plan formulation...2
6 Information recording and reporting...6
7 Other...7
Technical Guidelines for Self-Monitoring of Pollutants for Coal Processing - Syngas and Liquid Fuel Production
1 Scope of application
This standard specifies the general requirements for self-monitoring, monitoring plan formulation,
Basic content and requirements for information recording and reporting.
This standard is applicable to the water and air pollutants discharged from the coal processing industry by the production of syngas and liquid fuel pollutants during the production and operation stage.
Self-monitoring of pollutants, noise and impact on surrounding environmental quality.
In the production of syngas and liquid fuel pollutant discharge units, the self-monitoring of pollutant production facilities and discharge outlets in accordance with GB 31572 is carried out in accordance with HJ 947
Implementation; self-monitoring of self-provided thermal power generating units (plants) and supporting power boilers is implemented in accordance with HJ 820; self-monitoring of solid waste incineration facilities
Monitoring is performed according to HJ 1205.
2 Normative references
This standard refers to the following documents or clauses thereof. For dated references, only the dated version applies to this standard.
For undated references, the latest edition (including all amendments) applies to this standard.
GB 14554 Emission Standard of Odor Pollutants
GB 31571 Pollutant discharge standard for petrochemical industry
GB 31572 Emission Standard of Pollutants for Synthetic Resin Industry
GB 37822 Volatile organic compound fugitive emission control standard
HJ 2.2 Technical Guidelines for Environmental Impact Assessment Atmospheric Environment
HJ 2.3 Technical Guidelines for Environmental Impact Assessment Surface Water Environment
HJ 91.2 Technical Specification for Surface Water Environmental Quality Monitoring
HJ 164 Technical Specification for Groundwater Environmental Monitoring
HJ/T 166 Technical Specification for Soil Environment Monitoring
HJ 194 Technical Specification for Manual Monitoring of Ambient Air Quality
HJ 442.8 Technical Specifications for Environmental Monitoring in Offshore Sea Areas Part VIII Direct Sea Pollution Sources and Impact on the Water Environment in Offshore Sea Areas
monitor
HJ 610 Environmental Impact Assessment Technical Guidelines Groundwater Environment
HJ 819 General Principles of Technical Guidelines for Self-Monitoring of Pollutants
HJ 820 Technical Guide for Self-Monitoring of Pollutant Emission Units Thermal Power Generation and Boiler
HJ 947 Technical Guidelines for Self-Monitoring of Pollutant Emission Units Petrochemical Industry
HJ 964 Environmental Impact Assessment Technical Guidelines Soil Environment (Trial)
HJ 1101 Technical Specification for Pollutant Discharge Permit Application and Issuance Coal Processing - Syngas and Liquid Fuel Production
HJ 1200 Technical Specification for Pollution Discharge Permit Application and Issuance Industrial Solid Waste (Trial)
HJ 1205 Technical Guidelines for Self-Monitoring of Pollutant Discharge Units Solid Waste Incineration
"National Hazardous Waste List"
3 Terms and Definitions
The terms and definitions defined in GB 31571 and the following apply to this standard.
3.1
Pollutant emission unit of coal-based synthesis gas
Using coal or coke as raw material, oxygen (air, oxygen-enriched or pure oxygen), water vapor, etc. as gasification agent, chemical reaction is carried out under high temperature conditions.
The combustible part of coal or coke should be converted into a pollutant discharge unit of gas, and the effective components of gas include carbon monoxide, hydrogen and methane, etc.
The gas is used for industrial production or as a raw material for chemical production.
3.2
Pollutant emission unit of coal-based liquid fuel
Conversion of solid coal into liquid fuels, chemical feedstocks and products through chemical processing (e.g. coal-to-methanol, coal-to-dimethyl ether, coal
The pollutant discharge unit of ethylene glycol, coal-to-oil, coal-to-olefin, etc.).
3.3
rainwater outlet
A discharge outlet that specifically discharges natural precipitation to outside the factory boundary directly or through ditch, canal or pipeline and other facilities.
4 General requirements for self-monitoring
The pollutant discharging unit should find out the pollution source, pollutant index and potential environmental impact of the unit, formulate a monitoring plan, set up and maintain monitoring
facilities, carry out self-monitoring in accordance with the monitoring plan, do a good job in quality assurance and quality control, record and save monitoring information, and disclose it to the public in accordance with the law
Monitoring results.
5.Development of monitoring plan
5.1 Wastewater discharge monitoring
The wastewater discharge monitoring points, monitoring indicators and minimum monitoring frequency of sewage discharge units shall be implemented in accordance with Table 1.
6.1.2 Information record of the operation status of production and pollution control facilities
6.1.2.1 General provisions
The pollutant discharging unit shall record the operation status of production and pollution control facilities in detail, and shall also refer to 6.1.2.2~6.1.2.5 to record relevant records in daily production.
information, and organize it into a ledger for future reference.
6.1.2.2 Production Health Record
Record the operating status and production load of each unit of each main production unit under normal working conditions by shift, focusing on recording the raw material consumption,
Amount of auxiliary materials, output of main products, output of by-products, water intake (fresh water), raw and auxiliary materials and fuel usage (including types, names,
parameters such as dosage, composition and proportion of elements such as sulfur and heavy metals), running time and so on.
The operation of public and auxiliary facilities such as storage tanks, flare systems, power stations, etc., storage tanks include design scale, process parameters (temperature, liquid level, cycle
The torch system should record the ignition facilities and the working state of the torch.
6.1.2.3 Records of the operation status of wastewater pollution control facilities
Record sewage treatment volume, return water consumption, reuse rate, sewage discharge amount, sludge production amount, and name of chemicals used in sewage treatment by shift
Record the operation, failure and maintenance of sewage treatment facilities, etc.
Evaporation ponds should record the influent water quality, influent water volume and liquid level.
6.1.2.4 Records of operating status of waste gas pollution control facilities
Record the operating time, operating parameters, faults and maintenance of the facility, etc., and record the adsorbents and filtration used for waste gas treatment according to the replacement batch.
Names and quantities of consumables such as materials.
6.1.2.5 Records of the status of noise pollution control facilities
Record the daily inspection, failure and maintenance or replacement of noise pollution control facilities.
6.1.3 General Industrial Solid Waste and Hazardous Waste Records
Record the relevant information of industrial solid waste according to HJ 1200, see Table 6 for the generation of solid waste. Hazardous waste that may be generated by
According to the "National List of Hazardous Wastes" or the identification standards and identification methods of hazardous wastes.
6.2 Information reporting, emergency reporting and information disclosure
Execute in accordance with HJ 819.
7 Others
The pollutant discharge unit should truthfully record the working conditions during the manual monitoring period (including production load, operation of pollution control facilities, etc.) to ensure monitoring
Data are representative. The marking of working conditions during automatic monitoring shall be carried out in accordance with the national standard specifications and the rules of marking of working conditions of relevant industries.
Content not specified in this standard shall be implemented in accordance with HJ 819.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of HJ 1247-2022_English be delivered?Answer: Upon your order, we will start to translate HJ 1247-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of HJ 1247-2022_English with my colleagues?Answer: Yes. The purchased PDF of HJ 1247-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|