|
US$669.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. HJ 1105-2020: Technical specification for application and issuance of pollutant permit - Medical organization Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| HJ 1105-2020 | English | 669 |
Add to Cart
|
5 days [Need to translate]
|
Technical specification for application and issuance of pollutant permit - Medical organization
| Valid |
HJ 1105-2020
|
Standard similar to HJ 1105-2020 HJ 1097 HJ 1098 HJ 1096
Basic data | Standard ID | HJ 1105-2020 (HJ1105-2020) | | Description (Translated English) | Technical specification for application and issuance of pollutant permit - Medical organization | | Sector / Industry | Environmental Protection Industry Standard | | Word Count Estimation | 29,257 | | Date of Issue | 2020 | | Date of Implementation | 2020-02-28 | | Issuing agency(ies) | Ministry of Ecology and Environment |
HJ 1105-2020: Technical specification for application and issuance of pollutant permit - Medical organization ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specification for application and issuance of pollutant permit - Medical organization
National Environmental Protection Standards of the People's Republic of China
Technical specifications for pollutant discharge permit application and issuance
Medical institutions
2020-02-28 release
2020-02-28 Implementation
Issued by the Ministry of Ecology and Environment
Table of contents
Foreword...II
1 Scope of application...1
2 Normative references...1
3 Terms and definitions...2
4 Requirements for the basic information of pollutant discharge units...2
5 Production and discharge links and methods for determining permitted emission limits...7
6 Feasible technical requirements...8
7 Self-monitoring management requirements...9
8 Environmental management ledger records and implementation report preparation requirements...11
9 Accounting Method of Actual Emissions...14
10 Compliance Judgment Method...15
Appendix A (informative appendix) Reference table of feasible technologies for waste gas and wastewater treatment...17
Appendix B (Informative Appendix) Environmental Management Ledger Record Reference Table...18
Appendix C (Informative Appendix) Compilation Contents of Pollution Discharge Permit Implementation Report...20
Foreword
In order to implement the Environmental Protection Law of the People’s Republic of China, the Air Pollution Prevention and Control Law of the People’s Republic of
Pollution Prevention Law, Medical Waste Management Regulations and other laws and regulations, and the General Office of the State Council on Issuing the Permit System for Controlling Pollutant Discharge
"Notice of Implementation Plan" (Guobanfa [2016] No. 81) and "Administrative Measures for Pollution Discharge Permits (Trial)" (Order No. 48 of the Ministry of Environmental Protection)
To improve the technical support system for pollutant discharge permits, guide and standardize the application and issuance of pollutant permits by medical institutions, and formulate this standard.
This standard specifies the basic requirements for the application and issuance of pollution discharge permits for medical institutions, the requirements for permit emission limits, and compliance determinations
Management requirements such as methods, self-monitoring, environmental management ledger, and pollution discharge permit implementation report put forward feasible technical requirements for pollution prevention and control.
The appendix of this standard is an informative appendix.
This standard is issued for the first time.
This standard is formulated by the Department of Environmental Impact Assessment and Emission Management and the Department of Regulations and Standards of the Ministry of Ecology and Environment.
Drafting organizations of this standard. Shenyang Environmental Science Research Institute, Hospital Management Research Institute of National Health and Family Planning Commission, Environmental Planning Institute of Ministry of Ecology and Environment,
Beijing Comprehensive Research Center of Chinese Academy of Sciences.
This standard was approved by the Ministry of Ecology and Environment on February 28, 2020.
This standard will be implemented on February 28, 2020.
This standard is interpreted by the Ministry of Ecology and Environment.
1Pollution permit application and issuance of technical specifications for medical institutions
1 Scope of application
This standard specifies the basic requirements for filling out the application and issuance of the pollutant discharge permit by the pollutant discharge unit of the medical institution, the determination of the permitted discharge limit,
The method of actual emission calculation and compliance determination, as well as environmental management requirements such as self-monitoring, environmental management ledger, and pollution discharge permit implementation report,
Proposed feasible technical requirements for pollution prevention and control of pollutant discharge units in medical institutions.
This standard is applicable to guiding medical institutions’ pollutant discharge units to fill in relevant application information on the national pollutant discharge permit management information platform.
The guiding and issuing authority shall review and determine the licensing items of the pollution discharge permit for medical institutions.
This standard is applicable to the discharge permit management of air pollutants, water pollutants and hazardous wastes discharged by pollutant discharge units of medical institutions.
The production facilities or discharge outlets of the medical institution’s pollutant discharge units that implement the "Boiler Air Pollutant Emission Standard" (GB 13271) are applicable to the "Emission
Application for Pollution Permit and Issuance of Technical Specifications for Boilers (HJ 953).
This standard does not make provisions, but other products of medical institutions that discharge waste water, exhaust gas or toxic and harmful pollutants specified by the state
Pollution facilities and discharge outlets shall be implemented in accordance with the "General Rules for the Application and Issuance of Pollution Permits" (HJ 942).
2 Normative references
This standard quotes or refers to the following documents or their terms. For undated references, the latest version applies to this standard.
GB 8978 Integrated Wastewater Discharge Standard
GB 14554 Emission Standard of Odor Pollutants
GB 16297 Comprehensive Emission Standard of Air Pollutants
GB 18466 Water Pollutant Discharge Standard for Medical Institutions
GB 18597 Pollution Control Standard for Hazardous Waste Storage
HJ/T 55 Technical Guidelines for Monitoring Unorganized Emissions of Air Pollutants
HJ 91.1 Technical Specification for Wastewater Monitoring
HJ/T 353 Water Pollution Source Online Monitoring System Installation Technical Specification (Trial)
HJ/T 354 Technical Specification for Acceptance of Online Water Pollution Source Monitoring System (Trial)
HJ/T 355 Water Pollution Source Online Monitoring System Operation and Assessment Technical Specification (Trial)
HJ/T 356 Technical Specification for Data Validity Judgment of Online Water Pollution Source Monitoring System (Trial)
HJ/T 397 Fixed source exhaust gas monitoring technical specification
HJ 421 Standard for special packaging bags, containers and warning signs for medical waste
HJ 493 Technical Regulations for Storage and Management of Water Quality Samples
HJ 494 Technical Guide for Water Quality Sampling
HJ 495 Technical Regulations for Water Quality Sampling Scheme Design
HJ 521 Wastewater Discharge Law Code (Trial)
HJ 608 Code Rules for Pollutant Discharge Units
2HJ 819 General Rules of Technical Guidelines for Self-monitoring of Pollutant Discharge Units
HJ 905 Technical Specification for Environmental Monitoring of Odor Pollution
HJ 942 General Rules of Technical Specifications for Pollution Discharge Permit Application and Issuance
HJ 944 General Rules of Technical Specifications for Environmental Management Ledger and Pollution Discharge Permit Implementation Report of Pollutant Discharge Units (Trial)
HJ 953 Sewage discharge permit application and issuance of technical specifications for boilers
HJ 2029 Hospital Sewage Treatment Engineering Technical Specification
"List of Classification Management of Discharge Permits for Fixed Pollution Sources"
"Medical Waste Management Regulations" (State Council Order No. 380)
"Management Measures for Pollution Discharge Permits (Trial)" (Ministry of Environmental Protection Order No. 48)
"National Hazardous Waste List" (Order No. 39 of the Ministry of Environmental Protection)
"Measures for the Management of Medical Waste from Medical and Health Institutions" (Order No. 36 of the Ministry of Health)
"Technical Specifications for Centralized Disposal of Medical Wastes" (Huanfa [2003] No. 206)
"Guide to Hospital Sewage Treatment Technology" (Huanfa [2003] No. 197)
"Technical Requirements for Standardized Remediation of Sewage Outlets (Trial)" (Environmental Supervision [1996] No. 470)
"Medical Waste Classification Catalogue" (Health Medical Issue [2003] No. 287)
3 Terms and definitions
The following terms and definitions apply to this standard.
3.1 Pollutant Emission Unit of Medical Organization
Sewage discharge units of medical institutions refer to general hospitals, hospitals of traditional Chinese medicine, hospitals of traditional Chinese medicine and western medicine established by legal procedures that are engaged in disease diagnosis and treatment
Hospitals, National Hospitals, Specialty Hospitals and Nursing Homes.
3.2 Medical Wastewater
Refers to various departments engaged in diagnosis and treatment activities such as outpatient clinics, wards, operating rooms, examination rooms, pathological dissection rooms, and radiology rooms of medical institutions, as well as
Diagnosis and treatment, life and fecal sewage discharged from clothing rooms, morgues, disinfection supply centers, and medical waste temporary storage rooms. When other pollution in medical institutions
Water mixed with the above-mentioned sewage shall be regarded as medical sewage.
3.3 Special Medical Wastewater
Refers to the medical wastewater generated by some departments of medical institutions that need to be pre-treated before discharge, including clinical laboratory, radiology, and pathology
The sewage containing the first pollutant produced by other departments, as well as the infectious disease department (including the non-communicable disease and tuberculosis specialist hospitals)
Department of Infectious Diseases and Tuberculosis).
3.4 Permitted Emission Limits
Refers to the maximum discharge concentration (or rate) and discharge volume of pollutants permitted by the pollutant discharge unit as specified in the pollution discharge permit.
4 Requirements for basic information of pollutant discharge units
4.1 General principles
The pollutant discharge unit shall fill in the corresponding information on the national pollution discharge permit management information platform in accordance with the requirements of this standard.
If the local ecological and environmental authorities at or above the municipal level divided into districts need to fill in the report or the pollutant discharge unit thinks it needs to be filled in, they can add content by themselves.
3 The local ecological and environmental authorities at or above the municipal level with districts may, in accordance with the local laws and regulations on environmental protection, increase the need to include the pollution discharge permit
And fill in the “management content added by the local ecological and environmental authorities with the right to issue approval” in the national pollution discharge permit management information platform
One column.
4.2 Basic information of pollutants
The basic information of the pollutant discharge unit of the medical institution should be filled with the name of the unit, whether it needs to be corrected, the license management category, the postal code, the industry category,
Whether it is put into production and the date of start-up, the latitude and longitude of the production and operation site, and whether the location is an environmentally sensitive area (such as the key atmospheric control area, total phosphorus
Nitrogen control zone), whether it is located in the industrial park and the name of the industrial park to which it belongs, the environmental impact assessment approval comment number (record number), local government
The document number of the government’s identification or filing of illegal projects, the document number of the total distribution plan of major pollutants, the total chemical oxygen demand indicator, and the ammonia nitrogen
Total indicators, total indicators of other pollutants (if any), etc.
When filling in the industry category, the pollutant discharge unit of the medical institution should select sanitation according to the actual situation of the medical institution (National Economic Classification Code Q84)
Under the corresponding industry category, the sewage unit of medical institutions with boilers should also increase the industry category of thermal production and supply (D443), or
The boiler (TY01).
4.3 Operating information and auxiliary facilities of medical institutions
4.3.1 Business information
The operating information of medical institutions includes. total number of hospital staff, total number of medical staff, number of beds; bed utilization rate in the past three years, average daily stay
Number of hospitals, average number of daily outpatient receptions, department information, etc.
When filling in the hospital department information, it is necessary to confirm whether it contains the infectious disease department (including infectious disease department and tuberculosis department), radiology department (including dialysis department), oral cavity
Departments of cavity, laboratory, pathology, and laboratories that discharge special medical wastewater.
4.3.2 Auxiliary facilities 1
Auxiliary facilities of medical institutions include. sewage treatment stations of medical institutions, hazardous waste temporary storage rooms and other pollutant treatment and disposal related facilities.
Happening. Fill in the facility parameters with the treatment capacity of the sewage treatment station (m3/d); the area of the temporary storage room for hazardous waste (m2).
4.4 Main raw and auxiliary materials
The main raw and auxiliary material information of the sewage disposal unit of medical institutions only fill in the information of the auxiliary materials such as chemical agents added in the sewage and waste gas treatment process, such as
Activated carbon, oxidizer, flocculant, coagulant, conditioner (dehydrating agent), demulsifier, defoamer, sodium hypochlorite, liquid chlorine, chlorine dioxide,
Ozone, chloramine, bleaching powder, deodorant, etc.
Fill in the designed annual usage (t/a) that matches the treatment capacity of the pollution control facility. If the medicament used contains toxic and hazardous substances, fill in
Report the composition and proportion of toxic and hazardous substances.
If the pollutant discharge unit has other content that needs to be explained, it can be filled in.
4.5 Production and discharge links, pollutants and pollution control facilities
4.5.1 General principles
In this standard, the waste gas included in the discharge permit management by the medical institution pollutant discharge unit is mainly the waste gas from the sewage treatment station; it is included in the discharge permit management
The sewage includes medical sewage, special medical sewage, and domestic sewage directly discharged into environmental water bodies; hazardous waste packages included in the management of sewage permits
Including medical waste, waste medicine, medicine and sewage treatment station sludge.
1 Auxiliary facilities are used to guide the filling of pollution-producing facility information in the main product and capacity information table in the system.
44.5.2 Exhaust gas
4.5.2.1 Waste gas pollution generation links, types of pollutants and pollution prevention facilities
The pollutant production links, types of pollutants and pollution prevention and control facilities of the sewage treatment station of the sewage treatment unit of the medical institution are shown in Table 1.The medical institution
The types of pollutants discharged by the unit are determined according to GB 18466.Where local regulations have stricter emission standards, follow their regulations.
4.5.2.2 Emission form
The emission form is divided into organized emission and unorganized emission. The odor-producing area is collected in a closed manner, and discharged through the exhaust tube and the height of the exhaust tube
If it is greater than or equal to 15 meters, fill it in as organized emissions; if there is no exhaust tube or the height of the exhaust tube is less than 15 meters, fill in it as unorganized emissions.
4.5.2.3 Discharge outlet type and setting requirements
The types of discharge outlets are divided into main discharge outlets and general discharge outlets. The organized discharge outlets of waste gas from sewage treatment stations are general discharge outlets. According to
Technical Requirements for Standardized Remediation of Pollution Outlets (for Trial Implementation)", local relevant management requirements, and fill in whether the discharge outlets meet the standardized requirements.
4.5.2.4 Number of pollution control facilities and discharge outlets
The number of pollution prevention facilities can be filled in with the internal number of the sewage disposal unit of the medical institution. If the sewage unit has no internal number, it will be entered according to HJ 608.
Line number and fill in.
The exhaust gas discharge port number should be filled with the existing number of the local ecological and environmental authority. If the local ecological
For serial number, it shall be numbered and filled in according to HJ 608.
4.5.2.5 Implementation standards for discharge outlets
The organized discharge of waste gas from sewage treatment stations of medical institutions shall comply with the GB 14554 discharge standard; the unorganized discharge shall comply with GB
18466 emission standard.
4.5.3 Sewage
4.5.3.1 Types of sewage, types of pollutants and pollution prevention facilities
See Table 2a for the types of sewage, types of pollutants, and pollution prevention and control facilities of the pollutant discharge units of infectious disease and tuberculosis specialist medical institutions.
See the table for the types of sewage, the types of pollutants, and pollution prevention and control facilities for sewage types, pollutants, and pollution prevention facilities of medical institutions in non-communicable disease and tuberculosis hospitals.
2b.
The sewage disposal unit of a comprehensive medical institution with an infectious disease department should separate the sewage of the infectious ward from the sewage of the non-infectious ward.
The sewage and feces can be combined with other sewage after being treated by a separate disinfection facility. With radiology, laboratory, laboratory, dental
The sewage disposal units of medical institutions in the Department of Pathology and Pathology, which are involved in the discharge of special medical sewage, shall undergo corresponding pretreatments and then combine with other medical sewage
Merged processing.
4.5.3.2 Emission method, emission destination and emission law
Discharge methods are divided into three methods. direct discharge, indirect discharge and no discharge.
The discharge destination includes no discharge, to the comprehensive sewage treatment station in the hospital, directly into the sea, and directly into natural water such as rivers, lakes, and reservoirs.
Environment, enter the urban sewer (re-enter the natural water environment such as rivers, lakes, reservoirs), enter the urban sewer (re-enter the sea), enter the urban sewage
The water treatment plant enters the industrial wastewater centralized treatment plant, enters other units and others.
When sewage directly enters or enters the environmental water body through urban sewers, the discharge rule should be filled in, and it is not necessary to fill in the indirect discharge and non-exhaust discharge.
Refer to HJ 521 for waste water discharge rules.
4.5.3.3 Number of pollution control facilities and discharge outlets
The number of pollution prevention facilities can be filled in with the internal number of the sewage disposal unit of the medical institution. If the sewage unit has no internal number, it will be entered according to HJ 608.
Line number and fill in.
The serial number of the sewage discharge outlet should be filled in with the existing serial number of the local ecological and environmental authority.
For serial number, it shall be numbered and filled in according to HJ 608.
4.5.3.4 Requirements for setting the discharge port
According to the "Technical Requirements for Standardized Remediation of Sewage Outlets (Trial)", relevant local management requirements, and the discharge of sewage units implemented by medical institutions
According to the regulations on the standardized setting of discharge outlets in the release standards, report whether the setting of sewage discharge outlets meets the standardized requirements.
4.5.3.5 Type of discharge port
The types of discharge outlets are divided into main discharge outlets and general discharge outlets. The main discharge outlets are the total discharge outlets of sewage from the major management medical institutions.
Simplify the management of the general discharge outlets for sewage from sewage units in medical institutions; departments or facilities containing heavy metals or radioactive special medical sewage
The discharge port is the main discharge port, and the special infectious medical sewage only shows the pretreatment situation; the separate domestic sewage discharge port is directly discharged into the environmental water
The main body is a general discharge outlet, and the discharge into the urban centralized sewage treatment facility only indicates the discharge destination.
4.5.3.6 Basic situation of discharge outlets
The discharge port where sewage directly enters or enters the environmental water body through the urban sewer is a direct discharge port, and the direct discharge port of sewage needs to be filled in. Basically
Information, including the name of the receiving water body, the functional target of the water body, the geographic coordinates of the receiving water body, etc. The information on the sewage discharge outlet in the river needs to be filled in the river discharge
Relevant information such as the number of the sewage outlet, the name of the sewage outlet into the river, and the approval number of the sewage outlet.
The discharge port of sewage entering the urban sewage treatment plant is an indirect discharge port. Basic information of the indirect discharge port of sewage shall be filled in, including the receiving city
The name of the town's centralized sewage treatment facility, the types of pollutants discharged by medical institutions, and the relevant pollutants implemented by the town's centralized sewage treatment facility
Emission standards.
4.5.3.7 Implementation standards for discharge outlets
Infectious diseases and tuberculosis specialist medical institutions shall implement the emission limit in Table 1 of GB 18466; non-communicable diseases and tuberculosis specialists
The pollutant discharge unit of the medical institution of the hospital implements the discharge limit in Table 2 of GB 18466.Where local regulations have stricter emission standards, follow their regulations.
4.5.5 Hazardous waste
4.5.5.1 Sources, types and treatment methods of hazardous waste
Hazardous wastes from sewage disposal units of medical institutions mainly include medical wastes, waste medicines, medicines, and sewage treatment station sludge.
See components and names refer to "Medical Waste Classification Catalog".
The sources of hazardous waste from sewage disposal units in medical institutions are mainly clinical departments, laboratories, physical examination centers, infectious wards, pharmacies, and
Radiology, sewage treatment stations, and places for teaching, experimentation, research and other medical activities.
Hazardous wastes from sewage disposal units of medical institutions shall be handed over to qualified units for disposal. If there are other disposal methods, supplementary explanation should be given.
The specific hazardous waste types and treatment methods of medical institutions are shown in Table 3.
4.5.5.2 The amount of hazardous waste generated, stored and transferred
Fill in the report based on the maximum value of production, storage, and transfer of sewage units in medical institutions in the past 3 years, and the unit of measurement is t/a.
4.6 Drawing requirements
The basic information of the sewage disposal unit of a medical institution should also include the sewage treatment process flow chart and the layout plan of the hospital area.
The layout plan of the courtyard should at least include the main facilities, public auxiliary facilities, and environmental protection facilities such as temporary storage rooms for hazardous waste, sewage treatment stations, etc.
Indicate the direction of rainwater and sewage collection and transportation in the courtyard, the location of the discharge o...
|