HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GBZ45-2010 English PDF

US$169.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GBZ45-2010: Diagnostic criteria of occupational trinitrotoluene cataract
Status: Valid

GBZ45: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GBZ 45-2010English169 Add to Cart 3 days [Need to translate] Diagnostic criteria of occupational trinitrotoluene cataract Valid GBZ 45-2010
GBZ 45-2002English279 Add to Cart 3 days [Need to translate] diagnostic Criteria of Occupational Trinitrotoluene Cataract Obsolete GBZ 45-2002

PDF similar to GBZ45-2010


Standard similar to GBZ45-2010

GBZ 57   GBZ 20   GBZ 49   GBZ 40   GBZ 37   GBZ 41   

Basic data

Standard ID GBZ 45-2010 (GBZ45-2010)
Description (Translated English) Diagnostic criteria of occupational trinitrotoluene cataract
Sector / Industry National Standard
Classification of Chinese Standard C60
Classification of International Standard 13.100
Word Count Estimation 7,794
Date of Issue 2010-03-10
Date of Implementation 2010-10-01
Older Standard (superseded by this standard) GBZ 45-2002
Quoted Standard GBZ 35; GB/T 16180
Regulation (derived from) Health-Communication (2010) No. 6
Issuing agency(ies) Ministry of Health of the People's Republic of China
Summary This standard specifies the principles of diagnosis and treatment of occupational trinitrotoluene cataract. This standard applies to the diagnosis and treatment of occupational trinitrotoluene cataract.

GBZ45-2002: diagnostic Criteria of Occupational Trinitrotoluene Cataract

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
diagnostic Criteria of Occupational Trinitrotoluene Cataract ICS 13.100 C60 GBZ People's Republic of China National Occupational Health Standards Diagnostic criteria of occupational trinitrotoluene cataract Released in.2002-04-08 2002-06-01 Implementation Issued by the Ministry of Health of the People's Republic of China

Foreword

Article 6.1 of this standard is recommended and the remainder is mandatory. According to the "People's Republic of China Occupational Disease Prevention Law" to develop this standard. Since the implementation of the standard date, the original standard GB 11512-1989 inconsistent with this standard, subject to this standard. In the professional activities, long-term exposure to trinitrotoluene operators can cause changes in the lens lens opacity as the main performance of the Toxic eye disease, in order to be able to early diagnosis and correct treatment, in order to protect the health of the operator, the development of this standard. Appendix A to this standard is an informative appendix and Appendix B is a normative appendix. This standard is proposed and centralized by the Ministry of Health of the People's Republic of China. This standard is drafted by the Third Hospital of Peking University, China Center for Disease Control and Prevention Occupational Health and Poisoning Control Add grass. This standard is interpreted by the Ministry of Health of the People's Republic of China. Diagnostic criteria of occupational trinitrotoluene cataract Occupational chronic trinitrotoluene cataract is due to long-term exposure to trinitrotoluene caused by ocular lens opacity Become the main manifestation of toxic eye diseases.

1 Scope

This standard specifies the diagnostic criteria and principles of occupational trinitrotoluene cataract. This standard applies to occupational exposure to trinitrotoluene. Clinically met with this standard in the diagnosis and classification standards Describe the morphological characteristics, and indeed a close contact with trinitrotoluene, according to the principles of this standard for diagnosis and treatment.

2 normative reference documents

The terms of the following documents are hereby incorporated by reference into this standard. Any date that references the date of the document All subsequent amendments (excluding corrigenda) or revisions do not apply to this standard, however, The parties to the agreement are able to use the latest version of these documents. Those who do not mind the date of the reference file, its latest The version applies to this standard. GBZ 35 diagnostic criteria for occupational cataracts

3 diagnostic principles

According to the close occupational exposure history and the clinical manifestations of changes in lens opacity, combined with the necessary dynamic view Investigation, referral operating environment survey, comprehensive analysis, excluding other causes caused by lens damage, can be diagnosed.

4 observation object

Have one of the following performance, as the object of observation. a) thorough inspection, the lens around the circumference of the ring or near the ring point of the shadow; b) slit lamp microscopy, the lens around the Ministry of cortex scattered in the fine-like cloudy.

5 Diagnostic and grading standards

5.1 a cataract. thorough examination, the lens around the peripheral shadow, but the maximum ring width does not exceed the lens half One third of the diameter. The ring is made of a plurality of wedge-shaped turbulites, with the wedge facing the periphery, the tip pointing to the center, or the slit lamp Mirror to see the lens around the aggregation of the majority of the size of the gray-yellow fine-like cloudy, located in the cortex and adult nuclear, Cortical transparency is reduced. Distribution range with the former. 5.2 two cataracts. peripheral turbidity range than the lens radius of one third, but not more than two-thirds. Part of the case can be expressed as the central part of the lens appears equal to the size of the pupil diameter complete or incomplete annular turbidity, this mixed Turbidity is located in the former adult nucleus or anterior cortex. 5.3 three cataracts. the lens peripheral turbidity than the lens radius of more than two-thirds, or the central part of a dense point Or discoid opacity, visual function (vision and field of vision) are significantly affected.

6 Principles of handling

6.1 Principles of treatment Refer to GBZ 35 for treatment. 6.2 Other treatments 6.2.1 The subject is reviewed once a year. 6.2.2 Trinitrotoluene cataract diagnosis after the establishment of the principle should be transferred from trinitrotoluene operation; three patients may be appropriate to engage in light jobs.

7 Correctly use the instructions in this standard

See Appendix A (informative), Appendix B (normative).

Appendix A

(Informative) Correctly use the instructions in this standard A.1 The scope of application of this standard This standard applies only to occupational exposure to trinitrotoluene. Trinitrotoluene cataract lens opacity morphology, color, Distribution and other obvious characteristics, clinically met with the standard diagnosis and classification criteria described in the morphological characteristics, and Indeed, the history of close contact with trinitrotoluene can be diagnosed and treated according to the principles of this standard. A.2 Occupational contraindications See the relevant provisions of the Measures for the Administration of Occupational Health Surveillance. In other causes of cataract, Such as some drugs caused by lens opacity, early cataracts, etc., should be based on different clinical manifestations and specific circumstances Analysis, appropriate arrangements.

Appendix B

(Normative appendix) Eye examination requirements B.1 vision examination should include far, near vision and correct vision. B.2 asked the history should pay attention to whether the night blindness. B.3 routine external eye examination with the new blessing or compound tropicamide eye drops 3 times, to the eyes of the pupil fully dispersed, with direct Ophthalmoscopy examination of the lens, vitreous and fundus, and finally with the slit lamp microscope to check the lens, record the characteristics of the lesion, And the lesion is marked in the following format.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GBZ45-2010_English be delivered?

Answer: Upon your order, we will start to translate GBZ45-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GBZ45-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GBZ45-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GBZ45-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GBZ45-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.