US$724.00 ยท In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GBZ37627.3-2019: Radio interference characteristics of overhead power lines and high-voltage equipment -- Part 3: Code of practice for minimizing the generation of radio noise Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/Z 37627.3-2019 | English | 724 |
Add to Cart
|
5 days [Need to translate]
|
Radio interference characteristics of overhead power lines and high-voltage equipment -- Part 3: Code of practice for minimizing the generation of radio noise
| Valid |
GB/Z 37627.3-2019
|
PDF similar to GBZ37627.3-2019
Basic data | Standard ID | GB/Z 37627.3-2019 (GB/Z37627.3-2019) | | Description (Translated English) | Radio interference characteristics of overhead power lines and high-voltage equipment -- Part 3: Code of practice for minimizing the generation of radio noise | | Sector / Industry | National Standard | | Classification of Chinese Standard | L06 | | Classification of International Standard | 33.100.01 | | Word Count Estimation | 38,391 | | Date of Issue | 2019-06-04 | | Date of Implementation | 2020-01-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GBZ37627.3-2019: Radio interference characteristics of overhead power lines and high-voltage equipment -- Part 3: Code of practice for minimizing the generation of radio noise ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
GB /Z 37627.3-2019
Radio interference characteristics of overhead power lines and high-voltage equipment--Part 3. Code of practice for minimizing the generation of radio noise
ICS 33.100.01
L06
National Standardization Technical Document of the People's Republic of China
Overhead power lines and radios for high voltage equipment
Interference characteristics Part 3. Reducing radio
Noise to minimum implementation
equipment-Part 3. Codeofpracticeforminimizingthegenerationofradionoise
(CISPR/T R18-3..2010, IDT)
Published on.2019-06-04
2020-01-01 implementation
State market supervision and administration
China National Standardization Administration issued
Content
Foreword III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Practical design of overhead power lines and related equipment to control radio broadcast and television reception interference 1
4.1 Overview 1
4.2 Wire Corona 1
4.3 Gold Corona 2
4.4 Insulator surface discharge 2
4.4.1 Clean or slightly polluted insulators 2
4.4.2 heavily polluted insulators 2
4.5 Sparks and microsparks generated by poor contact and commutation
4.6 Defects in the operation of power lines and related equipment 3
5 Prediction method for overhead line reference level 3
5.1 Overview 3
5.2 Interrelationship of the information given in other chapters of this section 4
5.3 International Large Power Grid Conference (CIGRE) Formula 4
5.4 80% level determination 5
5.5 Conclusion 5
6 Minimize prevention and remedial measures and poor contact points for radio noise caused by poor contact
Detection and positioning 5
6.1 Overview 5
6.2 Prevention and remedial measures 5
6.3 Detection and location methods for bad contact points 7
7 Multi-split conductors (above 4 splits) and tubular conductors for radio noise field strength prediction formula 8
7.1 Basic Principles 8
7.2 Calculation of corona radio noise field generated by multi-split conductors 9
7.2.1 Calculation process of radio noise field strength 9
7.2.2 Calculation of the excitation function under heavy rain conditions 9
7.2.3 Calculating the correction factor of the excitation function under different weather conditions 9
7.2.4 Calculation of radio noise field strength 10
7.3 Calculation of radio noise field strength of large tubular conductors 10
8 Figure 11
Appendix A (informative) The prediction formula for the radio noise field strength of overhead line conductors 19
Appendix B (informative) Predictive analysis procedure for radio noise field strength at a given distance from a multi-split conductor overhead line 27
Reference 32
Foreword
GB /Z 37627 "Radio Interference Characteristics of Overhead Power Lines and High Voltage Equipment" currently includes the following parts.
--- Part 1. Description of the phenomenon;
--- Part 3. Implementation procedures to minimize radio noise.
This part is the third part of GB /Z 37627.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section uses the translation method equivalent to CISPR/T R18-3.2010 "Radio interference for overhead power lines and high voltage equipment.
Sexual Part 3. Code of Practice for Minimizing Radio Noise.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
---GB/T 4365-2003 Electrotechnical terminology electromagnetic compatibility [IEC 60050 (161)..1990, IDT]
---GB/T 11604-2015 High-frequency electrical equipment radio interference test method (IEC /T RCISPR18-2.2010, MOD)
--- GB /Z 37627.1-2019 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 1
(CISPR/T R18-1..2010, MOD)
This part is proposed and managed by the National Radio Interference Standardization Technical Committee (SAC/TC79).
This section was drafted. China Electric Power Research Institute Co., Ltd., Shanghai Electric Apparatus Research Institute, Xi'an High Voltage Electric Apparatus Research Institute
Responsible company, State Grid Co., Ltd., China National Accreditation Center for Conformity Assessment.
The main drafters of this section. Yan Xiong, Li Ni, Liu Yuan, Liu Wei, Chen Di, Wang Meishun, Lu Yao, Liu Xingfa, Cui Dong, Hao Yuliang, Zhang Jiangong,
Zhang Yemao, Xie Huichun, Gan Yuyuan, Zhou Bing.
Overhead power lines and radios for high voltage equipment
Interference characteristics Part 3. Reducing radio
Noise to minimum implementation
1 Scope
This part of GB /Z 37627 applies to overhead power lines and high-voltage equipment radio noise that may interfere with radio reception.
Sound, excluding the field generated by the power line carrier signal.
The frequency range involved is 0.15MHz~300MHz.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 60050-161 International Electrotechnical Vocabulary (IEV) Chapter 161. Electromagnetic Compatibility [International ElectrotechnicalVocab-
Uryy(IEV)-Chapter161. Electromagneticcompatibility]
CISPR/T R18-1.2010 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 1. Profiles
Interferencecharacteristicsofoverheadpowerlinesandhigh-voltageequipment-Part 1.Description
Ofphenomena)
CISPR/T R18-2.2010 Radio disturbance characteristics of overhead power lines and high-voltage equipment - Part 2. Methods and limits
Determination program (Radiointerferencecharacteristicsofoverheadpowerlinesandhigh-voltageequipment-
Part 2. Methodsofmeasurementandprocedurefordetermininglimits)
ISO /IEC Guide 99 International Metrology Glossary and General Concepts and Related Terms (VIM) [Internationalvocabu-
laryofmetrology-Basicandgeneralconceptsandassociatedterms(VIM)]
Note. Informational references are listed in the references.
3 Terms and definitions
The terms and definitions defined in IEC 60050-161 and ISO /IEC Guide 99 apply to this document.
4 Practical design of overhead power lines and related equipment to control radio broadcast and television reception interference
4.1 Overview
This chapter provides technical guidance for the design, construction and operation of overhead power lines and related equipment to enable the various types of radios described in this section.
The noise is kept within acceptable levels.
4.2 wire corona
In the circuit design, the geometric parameters should be considered to ensure that the radio noise generated by the wire corona does not exceed the specified acceptable water.
Flat, the most important parameters are the diameter of the wire and the number of splits per phase, other such as the distance between the phases, the height of the wire to the ground or the split wire
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZ37627.3-2019_English be delivered?Answer: Upon your order, we will start to translate GBZ37627.3-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GBZ37627.3-2019_English with my colleagues?Answer: Yes. The purchased PDF of GBZ37627.3-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|