GB/T 9978.2-2019: Fire Resistance Tests -- Elements of building construction -- Part 2: Guidance on measuring uniformity of furnace exposure on test samples
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 9978.2-2019English359 Add to Cart 4 days [Need to translate] Fire Resistance Tests -- Elements of building construction -- Part 2: Guidance on measuring uniformity of furnace exposure on test samples Valid GB/T 9978.2-2019

PDF similar to GB/T 9978.2-2019


Standard similar to GB/T 9978.2-2019

GB/T 9978.8   GB/T 7633   GB/T 9978.1   GB/T 9978.5   GB/T 9978.6   GB/T 9978.4   

Basic data

Standard ID GB/T 9978.2-2019 (GB/T9978.2-2019)
Description (Translated English) Fire Resistance Tests -- Elements of building construction -- Part 2: Guidance on measuring uniformity of furnace exposure on test samples
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard C82
Classification of International Standard 13.220.50
Word Count Estimation 18,128
Date of Issue 2019-12-10
Date of Implementation 2020-07-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 9978.2-2019: Fire Resistance Tests -- Elements of building construction -- Part 2: Guidance on measuring uniformity of furnace exposure on test samples


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Fire Resistance Tests--Elements of building construction--Part 2. Guidance on measuring uniformity of furnace exposure on test samples ICS 13.220.50 C82 National Standards of People's Republic of China Fire test method for building components Part 2. Fire test specimens exposed to fire Guide to measuring uniformity of action FireResistanceTests-Elementsofbuildingconstruction-Part 2. (ISO /T R834-2..2009, FireResistanceTests- Elementsofbuildingconstruction-Part 2. Guidanceonmeasuring uniformityoffurnaceexposureontestsampies, MOD) 2019-12-10 Release 2020-07-01 Implementation State Administration of Market Supervision Published by the National Standardization Management Committee

Contents

Foreword III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Test device 1 5 Test procedure 9 6 Test report 9 Appendix A (informative) This section is compared with the article number of ISO /T R834-2..200910 Appendix B (informative) Technical differences between this part and ISO /T R834-2..2009 and their causes 11 Appendix C (informative) Supplementary explanation 12 References 13

Foreword

GB/T 9978 Fire Test Method for Building Elements has been and plans to release the following sections. --- Part 1. General requirements; --- Part 2. Guidelines for measuring the uniformity of fire test specimens subjected to fire; --- Part 3. Test methods and test data application notes; --- Part 4. special requirements for load-bearing vertical partition members; --- Part 5. special requirements for load-bearing horizontal partition members; --- Part 6. special requirements for beams; --- Part 7. special requirements for columns; --- Part 8. Special requirements for non-load-bearing vertical partition members; --- Part 9. special requirements for non-load-bearing suspended ceiling members; This part is the second part of GB/T 9978. This section is drafted in accordance with the rules given in GB/T 1.1-2009. This part uses the redrafting method to modify and adopt ISO /T R834-2..2009 "Fire test building components-Part 2. Fire test Guidelines for Measuring the Uniformity of Specimen Fires. Compared with ISO /T R834-2..2009, this section has some structural adjustments.Appendix A lists ISO /T R834-2..2009. List of chapter number comparisons. Compared with ISO /T R834-2..2009, there are technical differences in this section.The terms related to these differences have been passed outside the corresponding clauses. The vertical single line (|) at the margin of the page is marked, and the corresponding technical differences and their causes are listed in Appendix B. This section is proposed by the Ministry of Emergency Management of the People's Republic of China. This section is under the jurisdiction of the National Fire Standardization Technical Committee (SAC/TC113). This section was drafted. Tianjin Fire Research Institute of Emergency Management Department. The main drafters of this section. Li Xiquan, Li Tao, Li Guohui, Zhao Huali, Hu Yuan, Zheng Wei, Huang Wei, Dong Xuejing, Diao Xiaoliang, Ruan Tao, Ran Lingji, Wang Yijie and Bai Bin.

Introduction

In accordance with the provisions of GB/T 9978.1, the test method recommended in this standard is used when the test specimen is subjected to a fire test in a fire test furnace. By measuring parameters such as temperature, air velocity and oxygen content in multiple locations in the test furnace, the uniformity of the specimens under fire can be judged. Push The recommended test method uses low-cost, easily-available lightweight materials to make sample samples, which can minimize the moisture content between different samples. The effect of the difference on the test results. Fire test method for building components Part 2. Fire test specimens exposed to fire Guide to measuring uniformity of action

1 Scope

This part of GB/T 9978 specifies a test method for measuring test specimens in a fire test furnace in accordance with GB/T 9978.1. The uniformity of the fire resistance during the fire test is determined. This section gives parameters such as temperature, air velocity, and oxygen content near the surface of the simulated specimen. The type and arrangement position of the measuring instrument are simulated. The inside of the simulated specimen is a cold-formed steel skeleton, and the surface of the fire-receiving surface of the specimen is a plasterboard. This section does not include performance requirements for fire test furnaces.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 9775 Paper Gypsum Board (GB/T 9775-2008, ISO 6308. 1980, MOD) GB/T 9978.1 Fire resistance test for building components-Part 1. General requirements (GB/T 9978.1-2008, ISO 834-1..1999, MOD)

3 terms and definitions

The terms and definitions defined in GB/T 9978.1 and the following apply to this document. 3.1 Effectiveareaoffurnaceopening Refractory test furnace opening area within the boundary of the instrument monitoring range.

4 Test device

4.1 Support structure (simulation test piece) 4.1.1 The support structure is made of cold-formed steel to support the keel.The fire-resistant surface of the support keel is installed with two layers of resistance that meet the requirements of GB/T 9775. Fire paper surface gypsum board (type H), the thickness of each layer of gypsum board is not less than 16mm; the back fire surface supporting the keel is installed with a thickness of not less than 18mm structural panel. Note. Use plywood or particle board as a typical structural panel. 4.1.2 In the supporting structure, the detailed assembly structure of cold-formed steel supporting keel, refractory paper-faced gypsum board and structural panel is shown in Figures 1 ~ 6. its Among them, Figures 1 to 3 are horizontal support structures, and Figures 4 to 6 are vertical support structures. In the support structure shown in the figure, the horizontal support structure is suitable For horizontal refractory test furnace with opening size of 3m × 4m; vertical support structure is suitable for vertical refractory with opening size of 3m × 3m Test furnace. For supporting structures used in other open-size fire-resistant test furnaces, the relevant dimensions need to be corrected.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 9978.2-2019_English be delivered?

Answer: Upon your order, we will start to translate GB/T 9978.2-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 9978.2-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 9978.2-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.