HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 9330.2-2008 English PDF

GB/T 9330.2: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 9330.2-2008EnglishRFQ ASK 5 days [Need to translate] Plastic insulated control cables -- Part 2: Polyvinyl chloride insulated and sheathed control cables Obsolete GB/T 9330.2-2008
GB 9330.2-1988EnglishRFQ ASK 9 days [Need to translate] Plastic insulated control cables--Polyvinyl chloride insulated and sheathed control cables Obsolete GB 9330.2-1988

PDF similar to GB/T 9330.2-2008


Standard similar to GB/T 9330.2-2008

GB/T 9330   GB/T 6995.3   GB/T 6995.2   GB/T 9326.2   GB/T 9326.3   GB/T 9326.1   

Basic data

Standard ID GB/T 9330.2-2008 (GB/T9330.2-2008)
Description (Translated English) Plastic insulated control cables -- Part 2: Polyvinyl chloride insulated and sheathed control cables
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 26,264
Date of Issue 2008-06-30
Date of Implementation 2009-04-01
Older Standard (superseded by this standard) GB 9330.2-1988
Quoted Standard GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.14-2008; GB/2951.31-2008; GB/T 2951.32-2008; GB/T 2952.1-1989; GB/T 3048.4-2007; GB/T 3048.5-2007; GB/T 3048.8-2007; GB/T 9330.1-2008; GB/T 19666-2005
Regulation (derived from) Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the rated voltage 450/750V and below PVC insulated and PVC sheathed control cable 's technical requirements. This section applies to rated voltage 450/750V control, monitor and protect the loop line and other occasions to use PVC insulated and PVC sheathed control cable. All cables shall comply with GB/T 9330. 1-2008 appropriate requirements prescribed, and various types of cables shall meet the special requirements of the provisions of this section.

GB/T 9330.2-2008: Plastic insulated control cables -- Part 2: Polyvinyl chloride insulated and sheathed control cables


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Plastic insulated control cables Part 2. Polyvinyl chloride insulated and sheathed control cables ICS 29.060.20 K13 National Standards of People's Republic of China Replacing GB 9330.2-1988 Plastic insulated control cable Part 2. PVC insulated and sheathed control cable Posted 2008-06-30 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 9330-2008 "plastic insulated control cable" is divided into three parts. --- Part 1. General requirements; --- Part 2. PVC insulated and sheathed control cable; --- Part 3. XLPE insulated control cable. This section GB/T 9330-2008 Part 2. This Part replaces GB 9330.2-1988 "plastic insulated control cables - Part 2. PVC insulated and sheathed control cable." This section compared with GB 9330.2-1988, the main changes are as follows. --- Added GB/T 19666-2005 references (Chapter 2 of this edition). --- Increased KVVP2-22 cable content (Excerpts of Table 1, Table 9); --- Increased KVV22 type 4-5 core 1.5mm2 size cable content (Excerpts of Table 2, Table 8); --- Increased content KVVR cable type, KVVRP type 2 or 3 core specifications (Excerpts of Tables 11 and 12); --- Increased KVVP type the first one kind of content cable conductor structure (Excerpts Table 6); --- Increased cable content KVVP3 aluminum/plastic composite tape shielding structure (Excerpts of Table 1, Table 7); --- Low temperature test cable test, test temperature can be adjusted to increase provisions (Excerpts of Tables 3 and 4) according to customer requirements; --- Adjust the lower and upper limits for the average outer diameter of the cable (Excerpts of Table 5 to Table 12); --- The finished cable performance test types canceled six months of periodic sampling test, to test sample (Table 12 of the 1988 edition; this Version Table 13). This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Kunming Cable Co., Ltd., Anhui days Kang (Group) Co., Ltd., Shandong Wanda Cable Co., The company, Qingdao Hanlan Co., Ltd., Zhejiang Chenguang Cable Co., Ltd. The main drafters of this section. package Hairong, Zhao Huang, He Wenjun, Xia Ximing, Wang Zhenqing, Zong will, money Shuifang. This part of the standard replaces the previous editions are. --- GB 9330.2-1988. Plastic insulated control cable Part 2. PVC insulated and sheathed control cable

1 Scope

GB/T 9330 provisions of this part of the rated voltage of 450/750V and below PVC insulated and PVC sheathed control cable Technical requirements. This section applies to the rated voltage of 450/750V and below control, monitor and protect the loop line and other occasions of PVC insulated And PVC sheathed control cable. All cables shall meet the appropriate requirements of GB/T 9330.1-2008 regulations, and various types of cable should conform to this part of the Regulation Given special requirements.

2 Normative references

The following documents contain provisions which, through reference to GB/T 9330 to the present, constitute provisions of this standard. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to this part of the standard Research on the parties to reach an agreement to use the latest versions of these documents. For undated references, the latest version applies to This section. GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side Law --- Measurement of thickness and overall dimensions - mechanical tests (IEC 60811-1-1.2001, IDT) GB/T 2951.12-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 12. General test side Law --- Thermal aging methods (IEC 60811-1-2. 1985, IDT) GB/T 2951.14-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 14. General test side --- Low temperature test method (IEC 60811-1-4.1985, IDT) GB/T 2951.31-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 31. Polyvinyl chloride mixture Special test methods --- high temperature pressure test - resistance to cracking (IEC 60811-3-1.1985, IDT) GB/T 2951.32-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 32. Polyvinyl chloride mixture Special test methods --- Loss of mass test - Thermal stability test (IEC 60811-3-2.1985, IDT) GB/T 2952.1-1989 cable outer sheath General GB/T 3048.4-2007 electrical wire and cable performance test methods - Part 4 DC resistance of conductors GB/T 3048.5-2007 electrical wire and cable performance test methods Part 5 Insulation resistance test GB/T 3048.8-2007 electrical wire and cable performance test methods Part 8 AC voltage test (IEC 60060-1. 1989, NEQ) GB/T 9330.1-2008 plastic insulated control cables - Part 1. General requirements GB/T 19666-2005 retardant and fire-resistant wire and cable General

3 Use Characteristics

3.1 Rated voltage Rated voltage U0/U is 450/750V. 3.2 Cable operating temperature Cable conductor long-term allowable working temperature of 70 ℃.