US$279.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 8815-2008: Plasticized polyvinyl chloride (PVC) compounds for wire and cable Status: Valid GB/T 8815: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 8815-2008 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Plasticized polyvinyl chloride (PVC) compounds for wire and cable
| Valid |
GB/T 8815-2008
|
GB/T 8815-2002 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Wire and cable with soft PVC
| Obsolete |
GB/T 8815-2002
|
GB 8815-1988 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Plasticized polyvinyl chloride (PVC) compounds for wire and cable
| Obsolete |
GB 8815-1988
|
PDF similar to GB/T 8815-2008
Basic data Standard ID | GB/T 8815-2008 (GB/T8815-2008) | Description (Translated English) | Plasticized polyvinyl chloride (PVC) compounds for wire and cable | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K15 | Classification of International Standard | 29.060.20 | Word Count Estimation | 12,186 | Date of Issue | 2008-12-30 | Date of Implementation | 2009-09-01 | Older Standard (superseded by this standard) | GB/T 8815-2002 | Quoted Standard | GB/T 1033-1986; GB/T 1040.3-2006; GB/T 1408.1-2006; GB/T 1409-2006; GB/T 1410-2006; GB/T 2406-1993; GB/T 2951.7-1997; GB/T 5470-1985 | Regulation (derived from) | Announcement of Newly Approved National Standards No. 24 of 2008 (No. 137 overall) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the wire and cable with a soft PVC (hereinafter referred to as PVC cable) Classification and nomenclature, appearance and color, requirements, test methods, inspection rules and signs, packaging, transportation and storage. This standard applies to PVC resin as the main raw material, adding a plasticizer, stabilizer additives, mixed plastics, into the grain and prepared with a soft PVC wire and cable. |
GB/T 8815-2008: Plasticized polyvinyl chloride (PVC) compounds for wire and cable---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Plasticized polyvinyl chloride (PVC) compounds for wire and cable
ICS 29.060.20
K15
National Standards of People's Republic of China
Replacing GB/T 8815-2002
Wire and cable with a soft PVC
Posted 2008-12-30
2009-09-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard replaces GB/T 8815-2002 "soft PVC wire and cable."
This standard compared with GB/T 8815-2002 The main changes are as follows.
--- To increase the impact embrittlement test based on the determination;
--- The breaking elongation to tensile strain;
--- Will change after aging elongation at break after aging tensile strain;
--- The biggest change in elongation at break Tensile strain rate to the maximum rate of change;
--- Expand the number of groups batches;
--- Increased by reference.
The standard proposed by China National Light Industry Council.
This standard by the National Standardization Technical Committee of plastic products.
This standard was drafted. Shanghai the new polymer materials Co., Ltd., Shanghai Electric Cable Research Institute.
The main drafters of this standard. Zhongwei Qin, Xiang Jian, Yan-Ping Zhang, Gong Hua Bin Shen Hua.
This standard replaces the standards previously issued as follows.
--- GB/T 8815-1988, GB/T 8815-2002.
Wire and cable with a soft PVC
1 Scope
This standard specifies the use of soft PVC wire and cable (hereinafter referred to as PVC cable) Classification and nomenclature, appearance and color,
Requirements, test methods, inspection rules and signs, packaging, transportation and storage.
This standard applies to PVC resin as the main raw material, adding a plasticizer, stabilizer additives, mixed plastics, granulating and prepared
Wire and cable with a soft PVC.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1033-1986 plastic density and relative density test method
GB /1040.3-2006 Plastics Determination of tensile properties T - Part 3. Test conditions for films and sheets (ISO 527-3.
1995, IDT)
GB/T 1408.1-2006 electrical insulating materials strength test methods - Part 1. Tests at power frequencies (IEC 60243-1.1998,
IDT)
GB/T 1409-2006 Measurement of electrical insulating materials at power, audio, high-frequency (including meter wavelengths included) of the permittivity and dielectric loss
Consumption factor recommended method (IEC 60250. 1969, MOD)
GB/T 1410-2006 solid insulating material volume resistivity and surface resistivity test methods (IEC 60093. 1980, IDT)
GB/T 2406-1993 Test method for flammability of plastic oxygen index
GB/T 2951.7-1997 cable insulation and sheathing materials test methods - Part 3. Test specific to PVC compounds
Method 2. Loss of mass test - Thermal stability test
Determination of GB/T 5470-1985 plastic brittle transition temperature shock method
3 Classification and nomenclature
3.1 Classification
Divided by use of PVC cable insulation level and retaining hierarchical categories.
3.2 Naming
According to the conductor operating temperature level and intended use by the Pinyin prefix numbers and different models.
Pinyin prefix and numbers have the following meanings.
--- J. insulation level;
--- H. protection level;
--- R. soft;
--- GD. high electrical performance;
--- Ⅰ. Ⅰ type;
--- Ⅱ. Ⅱ type;
--- 70,90. heat-resistant grade.
|