HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 8704.8-2009 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 8704.8-2009: Ferrovanadium -- Determination of aluminium content -- The chrome azurol S spectrophotometric method and EDTA titrimetric method
Status: Valid

GB/T 8704.8: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 8704.8-2009English209 Add to Cart 3 days [Need to translate] Ferrovanadium -- Determination of aluminium content -- The chrome azurol S spectrophotometric method and EDTA titrimetric method Valid GB/T 8704.8-2009
GB/T 8704.8-1994English319 Add to Cart 3 days [Need to translate] Methods for chemical analysis of ferrovanadium. The chromazurol S photometric method and EDTA volumetric method for determination of aluminium comtent Obsolete GB/T 8704.8-1994

PDF similar to GB/T 8704.8-2009


Standard similar to GB/T 8704.8-2009

GB/T 5686.7   GB/T 8704.5   GB/T 11170   GB/T 8704.6   GB/T 8704.10   GB/T 8704.3   

Basic data

Standard ID GB/T 8704.8-2009 (GB/T8704.8-2009)
Description (Translated English) Ferrovanadium -- Determination of aluminium content -- The chrome azurol S spectrophotometric method and EDTA titrimetric method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard H11
Classification of International Standard 77.100
Word Count Estimation 9,928
Date of Issue 2009-07-15
Date of Implementation 2010-04-01
Older Standard (superseded by this standard) GB/T 8704.8-1994
Quoted Standard GB/T 4010
Regulation (derived from) National Standard Approval Announcement 2009 No.9 (Total No.149)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the determination of vanadium iron and aluminum content photometric titration with EDTA Chromazurol S splitting. This section applies to the determination of vanadium iron aluminum content. Chromazurol S spectrophotometric measurement range (mass fraction): 0. 10% ~ 0. 80%, EDTA titration range (mass fraction): 0. 50% to 3. 50 %.

GB/T 8704.8-2009: Ferrovanadium -- Determination of aluminium content -- The chrome azurol S spectrophotometric method and EDTA titrimetric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Ferrovanadium.Determination of aluminium content.The chromazurol S spectrophotometric method and EDTA titrimetric method ICS 77.100 H11 National Standards of People's Republic of China Replacing GB/T 8704.8-1994 Determination of vanadium content of Fe-Al Chromium Azure S Spectrophotometry and EDTA titration Posted 2009-07-15 2010-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This Part replaces GB/T 8704.8-1994 "Methods for chemical analysis of ferrovanadium chrome azure S photometric method and EDTA volumetric method for the determination The amount of aluminum. " This portion of the GB/T 8704.8-1994 comparison, the main changes are. --- In the "Chromium Azure S Spectrophotometry" will be "accompanied by a blank solution in the sample as a reference" to "water as a reference." This part is proposed by the China Iron and Steel Association. This part of pig iron and ferroalloy by the National Standardization Technical Committee. This section is drafted. Sichuan Investment Emei Ferroalloy (Group) Co., Ltd. The main drafters of this section. should Tang Hua, Fang Yan. This part of the standard replaces the previous editions are. --- GB/T 8704.8-1994. Determination of vanadium content of Fe-Al Chromium Azure S Spectrophotometry and EDTA titration Warning --- Use this section shall be a person experiences regular laboratory work. This section does not point out all possible security asked question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.

1 Scope

This section GB/T 8704 specifies the use Chromium Azure S Spectrophotometry and EDTA titration ferrovanadium aluminum content. This section applies to the determination of vanadium iron aluminum content. Chromium Azure S Spectrophotometry range (mass fraction). 0.10% - 0.80%; EDTA titration range (mass fraction). 0.50% to 3.50%.

2 Normative references

The following documents contain provisions cited by GB/T 8704 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 4010 alloy chemical analysis and preparation of samples 3 Method One. Chromium Azure S Spectrophotometry 3.1 Principle Sample decomposition with nitric acid, sulfuric smoke, filtered, and the filtrate was saved shots. After ashing the residue with sulfuric acid and hydrofluoric acid to remove the oxide Silicon, followed by potassium pyrosulfate melt, combined in the master bath. Then remove iron, vanadium and other impurity ions with CUPFERRON and chloroform extraction. By sulfur Smoke acid, nitric acid treatment in the presence of hydroxylamine hydrochloride, with hexamethylenetetramine to adjust the pH, aluminum and chrome azure S form a colored complex matter, 550nm wavelength measured absorbance on a spectrophotometer. On the quality of the calibration curve Richard aluminum, aluminum in the sample is calculated content. 3.2 Reagents and materials Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled water or its equivalent purity water. 3.2.1 coke potassium sulfate solid. 3.2.2 chloroform. 3.2.3 hydrofluoric acid, ρ1.15g/mL. 3.2.4 nitrate, ρ1.42g/mL. 3.2.5 nitric acid, 1 + 1. 3.2.6 sulfuric acid, 1 + 1. 3.2.7 sulfate, 1 + 60. 3.2.8 sulfuric acid, 1 + 200. 3.2.9 ammonia, 1 + 1, stored in a plastic bottle. 3.2.10 CUPFERRON solution, 60g/L, with the preparation, use filtered. 3.2.11 hexamethylenetetramine solution, 400g/L. Weigh 200g hexamethylenetetramine placed in 600mL beaker, add water 500mL Dissolution, mixing, stored in plastic bottles. 3.2.12 hydroxylamine hydrochloride solution, 80g/L. Formulated with time.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 8704.8-2009_English be delivered?

Answer: Upon your order, we will start to translate GB/T 8704.8-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 8704.8-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 8704.8-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 8704.8-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 8704.8-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.