US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 8654.1-2007: Manganese metal, ferromanganese-silicon, ferromanganese and nitrogen-bearing ferromanganese -- Determination of iron content -- The ortho-phenanthridine spectrophotometric method and the titanium trichloride-potassium dichromate titrimetric method Status: Valid GB/T 8654.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 8654.1-2007 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Manganese metal, ferromanganese-silicon, ferromanganese and nitrogen-bearing ferromanganese -- Determination of iron content -- The ortho-phenanthridine spectrophotometric method and the titanium trichloride-potassium dichromate titrimetric method
| Valid |
GB/T 8654.1-2007
|
| GB/T 8654.1-1988 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Methods for chemical analysis of manganese metal--The ortho-phenanthroline photometric method for the determination of iron content
| Obsolete |
GB/T 8654.1-1988
|
PDF similar to GB/T 8654.1-2007
Basic data | Standard ID | GB/T 8654.1-2007 (GB/T8654.1-2007) | | Description (Translated English) | Manganese metal, ferromanganese-silicon, ferromanganese and nitrogen-bearing ferromanganese -- Determination of iron content -- The ortho-phenanthridine spectrophotometric method and the titanium trichloride-potassium dichromate titrimetric method | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | H11 | | Classification of International Standard | 77.100 | | Word Count Estimation | 8,845 | | Date of Issue | 2007-09-01 | | Date of Implementation | 2008-02-01 | | Older Standard (superseded by this standard) | GB/T 8654.1-1988; GB/T 8654.2-1988 | | Quoted Standard | GB/T 4010 | | Regulation (derived from) | China National Standard Approval Announcement2007 No.11 (Total No.111) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to manganese metal, manganese and ferromanganese nitride determination of iron content, manganese silicon alloy. Warning-Use this section personnel should experience regular laboratory work. This section does not indicate that all possible safety problems. Users are responsible for taking appropriate safety and health practices and to ensure compliance with the relevant national regulations. This part of the GB/T 8654 Determination of Manganese with the provisions of the phenanthroline spectrophotometry and titanium trichloride a dichromate method, ferromanganese and ferromanganese nitride iron content, manganese silicon alloy. Which phenanthroline spectrophotometric method for the determination of manganese metal in iron content. Measuring range (mass fraction): 0. 001% ~ l. 00%, titanium trichloride a dichromate method suitable for Manganese, manganese silicon alloy, determination of ferromanganese and ferromanganese nitride iron content. Measuring range (mass fraction): 1. 00%-35. 00%. |
GB/T 8654.1-2007: Manganese metal, ferromanganese-silicon, ferromanganese and nitrogen-bearing ferromanganese -- Determination of iron content -- The ortho-phenanthridine spectrophotometric method and the titanium trichloride-potassium dichromate titrimetric method
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Manganese metal, ferromanganese-silicon, ferromanganese and nitrogen - bearing ferromanganese Determination of iron content The ortho-phenanthrdine spectrophotometric method and the titanium trichloride-potassium dichromate titrimetric method..
ICS 77.100
H11
National Standards of People's Republic of China
Replacing GB/T 8654.1-1988, GB/T 8654.2-1988
Metal manganese, silicon manganese alloys, manganese and ferromanganese
Determination of iron content phenanthroline spectrophotometry
And titanium trichloride - potassium dichromate titration
Posted 2007-09-01 2008-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 8654 This section includes the phenanthroline spectrophotometric method and the titanium trichloride - potassium dichromate titration Determination of two metal manganese,
Silicon manganese alloys, manganese and ferromanganese analysis of iron content.
This Part replaces GB/T 8654.1-1988 "Methods for chemical analysis of manganese metal phenanthroline spectrophotometric determination of the amount of iron" and
GB/T 8654.2-1988 "Methods for chemical analysis of manganese metal - The titanium trichloride - potassium dichromate volumetric method for the determination of iron content."
This portion of the GB/T 8654.1-1988 and GB/T 8654.2-1988 comparison, the main changes are as follows.
--- Methods to extend the scope of the metal manganese metal manganese, silicon manganese alloys, manganese and ferromanganese;
--- Increased silicon manganese alloys, manganese and ferromanganese sample decomposition method;
--- Adjusted by the spectrophotometric measurement range from 0.001% to 0.31% and titration 1.00% to 5.00% of the spectrophotometry
0.001% to 1.00% and 1.00% titration ~ 35.00%;
--- Manganese metal sample size by 0.177mm 0.149mm sieve adjustments made through the sieve.
This part is proposed by the China Iron and Steel Association.
This section is under the jurisdiction of Metallurgical Industry Information Standards Institute.
This section is drafted. Sichuan Investment Emei Ferroalloy (Group) Co., Ltd.
The main drafters of this section. should Tang Hua, Fang Yan, Pu Haiyan.
This part of the standard replaces the previous editions are.
--- GB/T 8654.1-1988;
--- GB/T 8654.2-1988.
Metal manganese, silicon manganese alloys, manganese and ferromanganese
Determination of iron content phenanthroline spectrophotometry
And titanium trichloride - potassium dichromate titration
Warning --- Use this section shall be a person experiences regular laboratory work. This section does not point out all possible security asked
question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
GB/T 8654 This section provides the use phenanthroline spectrophotometric method and the titanium trichloride - Determination of manganese metal, manganese dichromate method
Silicon alloys, manganese and ferromanganese iron content.
This section applies to the metal manganese, silicon manganese alloys, manganese and ferromanganese nitride determination of iron content. Wherein phenanthroline spectrophotometric method adapted
Determination of manganese metal for iron content measurement range (mass fraction). 0.001% to 1.00%; titanium trichloride - potassium dichromate titration method applicable
In manganese metal, silicon manganese alloys, manganese and ferromanganese nitride Determination of iron content measurement range (mass fraction). 1.00% - 35.00%.
2 Normative references
The following documents contain provisions by GB/T 8654 this part of reference in terms of this section. For dated references
Documents, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Research into whether the parties to the agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 4010 alloy chemical analysis and preparation of samples
3 Method One. phenanthroline spectrophotometry
3.1 Principle
Sample decomposition with hydrochloric acid to adjust the pH value was added hydroxylamine hydrochloride solution was added phenanthroline iron color, wavelength spectrophotometer
Absorbance is measured at 517nm.
3.2 Reagents and materials
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled water or its equivalent purity water.
3.2.1 hydrochloric acid, 1 + 1.
3.2.2 hydrochloric acid, 50 + 1.
3.2.3 ammonium acetate solution, 500g/L.
3.2.4 hydroxylamine hydrochloride solution, 100g/L.
3.2.5 phenanthroline solution. Weigh 0.36g phenanthroline hydrochloride (C12H8N2HCl · H2O) were dissolved in 100mL of water.
3.2.6 Iron standard solution
3.2.6.1 0.5000g said high purity iron powder (purity not less than 99.9%) were placed in 300mL beaker, add 30mL of hydrochloric acid (3.2.1), plus
Thermal decomposition, after cooling transferred to 500mL volumetric flask, dilute with water to volume, and mix. This solution 1mL iron 1.0mg.
3.2.6.2 Pipette 25.00mL iron standard solution (3.2.6.1) in 1000mL volumetric flask, add 20mL hydrochloric acid (3.2.1), washed with water
Dilute to volume, and mix. This solution 1mL iron 25μg.
3.3 Instrument
Analysis using common laboratory instruments.
3.4 Sampling and Preparation
In accordance with the provisions of GB/T 4010 will be sampling and sample preparation. Specimens shall be by 0.149mm sieve.
|