US$169.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 8151.22-2020: Methods for chemical analysis of zinc concentrates - Part 22: Determination of zinc, copper, lead, iron, aluminium, calcium and magnesium contents - Wavelength dispersive X-ray fluorescence spectrometric method Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 8151.22-2020 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of zinc concentrates - Part 22: Determination of zinc, copper, lead, iron, aluminium, calcium and magnesium contents - Wavelength dispersive X-ray fluorescence spectrometric method
| Valid |
GB/T 8151.22-2020
|
PDF similar to GB/T 8151.22-2020
Basic data Standard ID | GB/T 8151.22-2020 (GB/T8151.22-2020) | Description (Translated English) | Methods for chemical analysis of zinc concentrates - Part 22: Determination of zinc, copper, lead, iron, aluminium, calcium and magnesium contents - Wavelength dispersive X-ray fluorescence spectrometric method | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | H13 | Classification of International Standard | 77.120.60 | Word Count Estimation | 9,985 | Date of Issue | 2020-09-29 | Date of Implementation | 2021-08-01 | Regulation (derived from) | National Standard Announcement No. 20 of 2020 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 8151.22-2020: Methods for chemical analysis of zinc concentrates - Part 22: Determination of zinc, copper, lead, iron, aluminium, calcium and magnesium contents - Wavelength dispersive X-ray fluorescence spectrometric method
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of zinc concentrates - Part 22.Determination of zinc, copper, lead, iron, aluminium, calcium and magnesium contents - Wavelength dispersive X-ray fluorescence spectrometric method
ICS 77.120.60
H13
National Standards of People's Republic of China
Chemical analysis methods of zinc concentrate
Part 22.zinc, copper, lead, iron, aluminum, calcium and magnesium
Determination of content
Wavelength Dispersive X-ray Fluorescence Spectrometry
Released on 2020-09-29 Implemented on 2021-08-01
State Administration for Market Regulation
Issued by the National Standardization Management Committee
Foreword
GB/T 8151 "Methods for Chemical Analysis of Zinc Concentrates" is divided into 23 parts.
---Part 1.Determination of the amount of zinc precipitation separation Na2EDTA titration method and extraction separation Na2EDTA titration method;
---Part 2.Determination of sulfur content, combustion neutralization titration method;
---Part 3.Determination of iron content by Na2EDTA titration;
---Part 4.Determination of the amount of silica molybdenum blue spectrophotometry;
---Part 5.Determination of lead content by flame atomic absorption spectrometry;
---Part 6.Determination of copper content by flame atomic absorption spectrometry;
---Part 7.Determination of arsenic content, hydride generation-atomic fluorescence spectrometry and potassium bromate titration;
---Part 8.Determination of cadmium content by flame atomic absorption spectrometry;
---Part 9.Determination of fluorine content ion selective electrode method;
---Part 10.Determination of tin content hydride generation-atomic fluorescence spectrometry;
---Part 11.Determination of the amount of antimony, hydride generation-atomic fluorescence spectrometry;
---Part 12.Determination of silver content by flame atomic absorption spectrometry;
---Part 13.Determination of the amount of germanium, hydride generation-atomic fluorescence spectrometry and phenylfluorenone spectrophotometry;
---Part 14.Determination of nickel content by flame atomic absorption spectrometry;
---Part 15.Determination of mercury content by atomic fluorescence spectrometry;
---Part 16.Determination of cobalt content by flame atomic absorption spectrometry;
---Part 17.Determination of the amount of zinc hydroxide precipitation-Na2EDTA titration;
---Part 18.Determination of the amount of zinc ion exchange-Na2EDTA titration;
---Part 19.Determination of gold and silver content, lead precipitation or ash blowing fire assay and flame atomic absorption spectrometry;
---Part 20.Determination of copper, lead, iron, arsenic, cadmium, antimony, calcium, magnesium content inductively coupled plasma atomic emission spectrometry;
---Part 21.Determination of thallium content by inductively coupled plasma mass spectrometry and inductively coupled plasma-atomic emission spectrometry;
---Part 22.Determination of zinc, copper, lead, iron, aluminum, calcium and magnesium content by wavelength dispersive X-ray fluorescence spectrometry;
---Part 23.Determination of mercury content Direct method of solid injection.
This part is part 22 of GB/T 8151.
This section was drafted in accordance with the rules given in GB/T 1.1-2009.
This part was proposed by China Nonferrous Metals Industry Association.
This part is under the jurisdiction of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243).
Drafting organizations of this section. Bayuquan Customs of the People's Republic of China, Nantong Customs Comprehensive Technology Center, Lianyungang Sea of the People's Republic of China
Guan, Shenzhen Zhongjin Lingnan Nonferrous Metals Co., Ltd., Xi'an Hantang Analysis and Testing Co., Ltd., Kunming Metallurgical Research Institute, Guangdong Province Industry
Analysis and Testing Center, Henan Yuguang Gold and Lead Co., Ltd., National Standard (Beijing) Inspection and Certification Co., Ltd., Liaoning University of Petroleum and Chemical Technology, Yang Guxiang
Guang Copper Industry Co., Ltd.
The main drafters of this section. Chu Ning, Jiang Xiaoguang, Wang Yanjun, Dou Huaizhi, Qin Lijun, Huang Zufei, Shi Jinhui, Xu Shi, Liao Guiping, Zhou Kai,
Yang Haijian, Wang Jin, Kong Jianmin, Hu Fangfei, Chu Gang, Wan Shuang, Sun Baolian, Luo Shun, Zhang Sheng, Xu Shuangbao, Wang Changhua, Song Yongqing, Yu Lei.
Chemical analysis methods of zinc concentrate
Part 22.zinc, copper, lead, iron, aluminum, calcium and magnesium
Determination of content
Wavelength Dispersive X-ray Fluorescence Spectrometry
1 Scope
This part of GB/T 8151 specifies the determination method of zinc, copper, lead, iron, aluminum, calcium and magnesium content in zinc concentrate.
This part is applicable to the determination of zinc, copper, lead, iron, aluminum, calcium and magnesium content in zinc sulfide concentrate by non-arbitration analysis. The measurement range is shown in Table 1.
Table 1 Measuring range
element
Measuring range (mass score)
Zn 24.00~62.00
Cu 0.20~2.80
Pb 0.15~4.00
Fe 2.50~15.00
Al 0.10~2.40
Ca 0.25~4.50
Mg 0.15~1.00
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
GB/T 16597 General Rules of X-ray Fluorescence Spectrometry for Analysis Methods of Metallurgical Products
JJG810 Wavelength Dispersive X-ray Fluorescence Spectrometer
3 Method summary
It is compounded in the order of flux, sample, oxidizer, silica and flux. At step temperature, the ternary mixed oxidant will
The qualitative elements and low-valent elements are oxidized into high-valent elements, and lithium bromide is used as a mold release agent. The sample is melted and cast to a dilution ratio of about
1.44 sample piece. Measure the X-ray fluorescence intensity of the characteristic spectrum of the element to be measured in the sample under the optimal measurement conditions of the instrument, and perform
The interference effect between elements is corrected, and the content of the element to be measured in the sample is obtained from the calibration curve.
4 Reagents or materials
Unless otherwise specified, only use reagents confirmed to be analytically pure and third-grade water that meets the requirements of GB/T 6682 in the analysis.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 8151.22-2020_English be delivered?Answer: Upon your order, we will start to translate GB/T 8151.22-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 8151.22-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 8151.22-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|